background image

EIDX_MP Series

 

A Line of Managed PoE PSE Ethernet Switching Hubs 

INSTALLATION GUIDE 

INTRODUCTION 

The EIDX_MP Series of managed Industrial Ethernet switches provides the user 
with  a sophisticated instrument with several advanced features for the 
discriminating network professional.  Each of the 8 models in the series operates 
in extended temperatures while offering a choice of mounting, port count, media 
support and 8 Power-Over-Ethernet ports (PoE). 

To optimise speed and throughput, some functions

 

are 

automatically negotiated

Each twisted-pair port automatically optimises its data rate to 10 Mbps or 100 
Mbps.  The data rate of fibre ports is fixed at 100 Mbps. 

Each port negotiates flow control — supporting the PAUSE function for full-
duplex links, and using the backpressure scheme for half-duplex segments. 

All units offer 

non-blocking wire-speed operation

 with a maximum data rate of 

148,810 frames per second for 100 Mbps Ethernet on all ports at full duplex. 
Copper ports are wired MDI-X (internal crossover) for attaching NICs via straight-
through cables. 

All units support SNMP and offer these advanced features: 

RapidRing™ high-speed redundancy (link loss recovery under 300 ms) 

VLANs to limit broadcast/multicast domains and improve performance 

Trunking to allow high-bandwidth redundant backbones 

QoS message priority for either port-based or MAC-based priority 

Programmable fault relay to indicate the loss or addition of a link 

Auto-MDIX for all copper ports enabled/disabled by software control 

All  units  operate  from  low-voltage  DC sources —  and redundant power 
connections are available for backup considerations.  They come with the ability 
for either DIN rail or panel mounting.  The front panel features LED indicators 
for power and CPU status — and link status, activity and data rate of each port. 

Summary of Contents for CTRLink EIDX MP Series

Page 1: ...gments All units offer non blocking wire speed operation with a maximum data rate of 148 810 frames per second for 100 Mbps Ethernet on all ports at full duplex Copper ports are wired MDI X internal crossover for attaching NICs via straight through cables All units support SNMP and offer these advanced features RapidRing high speed redundancy link loss recovery under 300 ms VLANs to limit broadcas...

Page 2: ...Listed Industrial Control Equipment intended for use with Class 2 circuits Functional Compliance ANSI IEEE 802 3 Data Rate 10 Mbps and 100 Mbps Signalling 10BASE T 100BASE TX 100BASE FX LED Indicators Power 48 V green Status red green Ports green yellow Fault red PoE Power green Mechanical Figure 1 EIDX Dimensions Warning This is a Class A product In a domestic environment the product may cause ra...

Page 3: ...TD071100 0IA 3 RJ 45 Connector Pin Assignments PIN MDI X PoE 1 TD TD 2 TD TD 3 RD RD 4 unused 48 V 5 unused 48 V 6 RD RD 7 unused 48 V return 8 unused 48 V return Figure 2 RJ 45 Connector ...

Page 4: ...f the EIDX enclosure with four M3x5 flat head screws If the clip is removed the EIDX can be panel mounted by extending the top and bottom brackets which are shipped in retracted position The extended brackets can then anchor the EIDX to a wall or other flat vertical surface with two 8 pan head screws not provided The left illustration of Figure 3 shows a rear view of the EIDX with brackets in retr...

Page 5: ...er media regardless of data rate Although 10BASE T links can successfully use Category 3 4 or 5 cable 100BASE TX segments must use Category 5 A popular choice for improved distance is multimode fibre which also gives good electromagnetic noise immunity and optimum protection from lightning strikes Considerable distance can be achieved in full duplex mode and the greatest distance can be realized i...

Page 6: ...Powered Redundant diode isolated DC power inputs are provided so the EIDX can operate despite the loss of primary power Both sources must provide required power LED Indicators Power This LED glows green when proper power is applied to the EIDX Status This bicolour LED will be green in an operational state and red in a fault state The green LED blinks periodically to indicate the management CPU is ...

Page 7: ...is shown in Figure 6 which locates a few of the ports on the model EIDX24MP 100T FC Fault Relay This relay is disabled by default Its operation is explained in the Software Manual Its contact is normally closed and rated at 500 mA 24 V max Figure 6 Port Locations Console Port The Console Port uses the standard RS 232 protocol for configuring the switch For proper communication Set the Baud rate to...

Page 8: ...been damaged by abuse accident disaster misuse or incorrect installation User modification may void the warranty if the product is damaged by the modification in which case this warranty does not cover repair or replacement This warranty in no way warrants suitability of the product for any specific application IN NO EVENT WILL CC BE LIABLE FOR ANY DAMAGES INCLUDING LOST PROFITS LOST SAVINGS OR OT...

Reviews: