Cool Fin LED Hybrid series LED Street /Roadway /Area Light-347 V
Main specifications:
Model No.
Nominal
Wattage
Dimensions (L x W x H)
Weight
EPA
*
Working
Environment
IP
CFSLPMHBC80
80w
523
mm ( 20.6" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 7.1 kg ( 15.6 lbs. ) 0.5
-40
℃
―+50
℃
IP67
CFSLPMHBC120
120w
583
mm ( 22.9" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 8.2 kg ( 18.1 lbs. ) 0.54 -40
℃
―+50
℃
IP67
CFSLPMHBC160
160w
643
mm ( 25.3" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 8.9 kg ( 19.5 lbs. ) 0.59 -40
℃
―+50
℃
IP67
CFSLPMHBC200
200w
703
mm ( 27.7" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 10
kg ( 22.1 lbs. ) 0.63 -40
℃
―+50
℃
IP67
CFSLPMHBC240
240w
763
mm ( 30.1" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 11
kg ( 23.8 lbs. ) 0.67 -40
℃
―+50
℃
IP67
CFSLPMHBC280
280w
823
mm ( 32.4" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 11
kg ( 25.2 lbs. ) 0.72 -40
℃
―+50
℃
IP67
CFSLPMHBC320
320w
883
mm ( 34.8" ) x 345 mm ( 13.6" ) x 116 mm ( 4.6" ) 12
kg ( 27.5 lbs. ) 0.76 -40
℃
―+50
℃
IP67
Input Voltage: 347 to 480V~ 50/60Hz
IMPORTANT INSTALLATION INFORMATION
347 V - Cool Fin LED Hybrid series LED Street /Roadway /Area Light
INSTALLATION INSTRUCTION
• Ensure there is adequate free air circulation of at least 50cm around the luminaire. All luminaires run hot. It is the installer's responsibility to consider fire
risk and take appropriate precautions.
• The luminaire must not, under any circumstances, be installed directly to flammable materials, and luminaires must not be covered with any flammable
materials.
The ingress protection of the fixture is IP67 if the mains supply cable's specification is H07RN-F 3*1.5m
㎡
.
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE
• Before commencing installation or maintenance, ensure electricity is switched off at the mains. Installation or maintenance should be carried out by a
qualified electrician.
Drawings herein for
CFSLPMHBC 200 w are used as
examples for all the below
listed models
STEP 1:
Loosen nuts from pole locking bolts, then slide fixture
on to pole through opening (tenon) on the rear of housing.
See
Figure 1.
STEP 2:
Ensure to slide fixture to the inner end of tenon, then
tighten locking bolts with 5mm hex wrench or its equivalent to
ensure the fixture is fixed to pole firmly.
See Figure 1.
CFSLPMHBC200
The installation instruction is subject to change without prior notice.
For more about the product info, please visit www.arrlux.com or consult factory.
Page 1 of 2