background image

Fixture Type

Fitter Type

Pole Insert Depth

Medium Epic Spider Mount

4"

6" or Longer 

Large Epic Spider Mount

4"

6" or Longer 

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.

1.

Remove Pole Cap and let hang from fitter.

2

.

Position the service wires to feed through the bottom of the arm. Fig. 1.

3

.

Slip the arm onto the pole feeding the service wire leads to the interior of the arm. Fig. 2.

4.

Connect the service wires lead to the terminal block. Install the Pole Cap and tighten the (3) set screws (provided).
Rotate and position the arm on the pole so the street side and the fixture side are facing the correct direction. The street side 
label is located on the inside of the reflector. Fig. 2.

5.

Tighten and make sure that locite is applied to the (6) SS set screws (provided) located at the base of the arm. Fig. 2.

6.

Pole Application:

WARNING:

Do not use fixtures on poles or tennons smaller than noted below. Insure that upper most set screws engage the 
tenon/pole.

Customer First Center  •  1121 Hwy 74 South  •  Peachtree City, GA  30269

IMI-654     AVU071135

Epic/Pole Mounted

Fixtures

Sheet 1 of 1

6/18/07

IMI-654

INSTALLATION INSTRUCTIONS

IMPORTANT: 

Read carefully before installing fixture. Retain for future reference.

General:

Upon receipt of fixture thoroughly inspect for any

freight damage, which should be brought to the attention of
the delivery carrier. Compare the catalog description listed
on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.

Safety:

This fixture must be wired in accordance with 

the national electrical code and applicable local codes 
and ordinance. Proper grounding is required to insure 
personal safety. Carefully observe grounding procedure
under installation section. All work should be done by a 
qualified electrician.

WARNING: 

Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.

AUXILLIARY

GROUND

TERMINAL BLOCK

SERVICE WIRES

SET SCREWS

POLE CAP

TERMINAL
BLOCK

SERVICE WIRES

FITTER

Fig. 1

Fig. 2

Reviews: