background image

The effects of ambient temperature and elevated tank pres-

sures on the speed of the refrigerant recovery process are 

in many cases more important than the speed of the recov-

ery machine itself. As the ambient temperature increases, 

the pressure in the recovery cylinder increases, significantly 

reducing the recovery speed and in many cases can lead to 

a high pressure shutdown as the recovery equipment and 

tank pressure limits are reached. 

The Pro-Set MT69 Molecular Transformator significantly 

reduces the temperature and pressure of recovered refriger-

ant during the recovery process, dramatically improving the 

recovery speed and high ambient temperature performance 

of all commercially available recovery machines in addition 

to extending the life of the equipment. The Pro-Set MT69 

is a patent pending “Innovation in Design” from CPS, in-

tended for use with all major brands of refrigerant recovery 

equipment. It is engineered for harsh field conditions and is 

extremely easy to use.  Please refer to the diagrams shown 

for details on the proper operation of the MT69.

Molecular Transformator

Operational Manual

MT69

General Safety Instructions

ONLY QUALIFIED SERVICE PERSONNEL SHOULD OPERATE THIS DEVICE.  MOST STATES, COUNTRIES, ETC., MAY 

REQUIRE THE USER TO BE LICENSED.  PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY.

Danger-

 

The recovery tank used in conjunction with this product contains liquid refrigerant.  Overfilling of the 

recovery tank may cause a violent explosion resulting in severe injury or even death.  Recovery tank weight should 

be continuously monitored using a scale specifically designed for this purpose.

Danger-

 Avoid breathing refrigerant vapors and/or lubricant mist.  Exposure may irritate eyes, nose, throat, and 

skin.  Breathing high concentration levels may cause heart arrhythmia, loss of consciousness, or even cause suf-

focation.  Please read the manufacturers Material Safety Data Sheet for further safety information on refrigerants 

and lubricants.

Caution-

 Contact with refrigerant may cause frostbite or other related injuries.  Wear proper personal protective 

equipment such as safety goggles and gloves.  Hoses may contain liquid refrigerant under pressure use extreme 

caution when disconnecting any hose.

Caution-

 This device is not a storage vessel for refrigerant.  It must have its contents removed after each use.  

Mixing of different refrigerants will cause your recovered supply of refrigerant to become contaminated .This unit 

should be evacuated after each use. 

Caution- 

Read and understand the refrigerant recovery unit manufacturer’s instructions. Always follow the manu-

facturers recommended safety procedures. 