1 of 2
LPN00336X0001A0_B
FP SERIES- LED FLAT PANEL
INSTALLATION INSTRUCTIONS
FP14, FP22, FP24 Luminaires
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before installation.
DANGER
– Risque de choc – Couper l’alimentation avant l’installation.
2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these
codes and requirements, consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et
ces exigences, veuillez contacter un électricien qualifié
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
T-BAR MOUNTING
STEP 1
• Locate desired position for fixture in ceiling grid.
STEP 2
• Remove appropriate ceiling panel.
STEP 3
• Place the fixture into the T-bar ceiling panel
location. Fold out (4) hanging clips in corners
of fixture and use clips to secure fixture to grid.
Ensure that state and local codes are followed.
See
Figure 1.
• NOTE:
** Not intended for use with 9/16” T-Bar
grids unless used with a 9/16” accessory clip like
“Armstrong® LFC- Fixture Clip” which can be
purchased through distribution. Consult factory
for non-standard grid applications. See
Figure
2.
STEP 4
• Make wiring connections per the
Electrical Con-
nection
section on the back page.
SUSPENDED MOUNTING
STEP 1
• For installation of suspended mount application
refer to installation instruction provided with in
the suspended mount kit, FPAC-45-1.
LUMINAIRE INSTALLATION
1
(4) Hanging Clips
2
Armstrong® LFC- Fixture Clip to
use for 9/16th applications.