Handling and Storage:
Environmental
Considerations
(1)
Storage temperature -20°C/+60°C.
(2)
Do not let water penetrate into packaging boxes during their storage and
transportation.
(3)
Do not store the product in places of high temperature or under direct
sunlight.
(4)
Please also avoid the places of high humidity. Be sure not to expose the
product to condensation, rain or frozen condition.
Install Environment:
NEMA Rating
CTP107-E Series HMI is NEMA 4 rated (Indoor Only).
Electrical
Environment
CTP107-E Series HMI has been tested to conform to European CE
requirements. This means that the circuitry is designed to resist the effects of
electrical noise. This does not guarantee noise immunity in severe cases. Proper
wire routing and grounding will insure proper operation.
Environmental
Considerations
(1)
Make sure that the displays are installed correctly and that the operating
limits are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2)
Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3)
Do not install the unit where acid gas, such as SO2 exists.
(4)
This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5)
Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in
Pollution Degree 2 Environment.
Unpacking the Unit
Installation Instructions
Secure the operator panel in position, using all the fastening holes and the provided brackets
and screws. Screw Torque: 0.29 ~ 0.44 N.m (For reaching waterproof effect and preventing the panel
from being deformed.)
Type
A(mm)
B(mm)
CTP107-E
192
138
USB Stick Clamp Usage
Combining the USB Stick with the clamp and the tying strap can prevent USB stick from disconnecting
with HMI when strong vibration is present.
1. Insert the USB connector to the clamp and tie them together with the tying strap.
2. Press the spring and insert the USB stick into HMI.
Power Connections
System Settings
When HMI is powered up and displays image,
click the system setting button.
(Default System Password: 111111)
It is necessary to connect the HMI to
your network through a RJ-45 cable.
CTP107-E series 88 970 564
Installation Instruction
Unpack and check the delivery. If damage
is found, notify the supplier.
NOTE:
Place the operator panel on a stable
surface during installation. Dropping it or
letting it fall may cause damage.
Go to the Network tab, you may choose
to auto get DHCP IP, or designate your
own IP.
NOTE:
1. Conne
ct positive DC line to the ‘+’ terminal and the DC
ground to
the ‘-’ terminal.
2. When using a USB cable to download project file, please
do not connect HMI with PLC and PC simultaneously to
prevent potential difference from destroying USB ports of
HMI and PC.
(A)
(B)
Cutout
3
5
4
(1)
(2)
(3)
(5)
(4)
(6)
(1) Installation Instruction, 2-sided A4 *1
(2) Human Machine Interface *1
(3) Power Connector *1
(4) Brackets & Screws *1 pack
(5) USB Stick Clamp & Tying Strap *1
(6) Fuse 1.25A/250V 5*20mm *1
1
2