background image

1

Crystal Quest

®

 UltraViolet Disinfection System

INSTALLATION AND OPERATION GUIDE

ONLINE WARRANTY INFORMATION

CrystalQuest.com/warranty.html

COMPONENT S

Copyright 2018

Crystal Quest

®

All rights reserved

MADE IN THE USA

MODELS:

CQE-UV-00101 

1 GPM 

 

CQE-UV-00106 

36 GPM

CQE-UV-00102 

6 GPM 

 

CQE-UV-00107 

48 GPM

CQE-UV-00103 

8 GPM 

 

CQE-UV-00108 

60 GPM

CQE-UV-00104 

12 GPM 

 

CQE-UV-00109 

72 GPM

CQE-UV-00105 

24 GPM 

 

CQE-UV-00110 

84 GPM

Summary of Contents for CQE-UV-00101

Page 1: ...CrystalQuest com warranty html COMPONENT S Copyright 2018 Crystal Quest All rights reserved MADE IN THE USA MODELS CQE UV 00101 1 GPM CQE UV 00106 36 GPM CQE UV 00102 6 GPM CQE UV 00107 48 GPM CQE UV 00103 8 GPM CQE UV 00108 60 GPM CQE UV 00104 12 GPM CQE UV 00109 72 GPM CQE UV 00105 24 GPM CQE UV 00110 84 GPM ...

Page 2: ...table safe to drink COLD water supply only Do not use the system where water is microbiologically unsafe or with water of unknown quality Turn the cold water line off while installing the system When installation is complete recheck the system to ensure there are no leaks or drips The UV system should be installed to meet local state and federal plumbing codes and health department rules and regul...

Page 3: ...special care should be taken since water is present near electrical equipment Carefully examine the UV Disinfection System after installation It should not be plugged in if there is water on parts not intended to be wet The outlet to plug in the UV Disinfection System must be within reach of the power cord Do not use an extension cord Extension cords that are too long or too light do not deliver s...

Page 4: ...st failure The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination For safety purposes the UV Disinfection System should be connected to a ground fault circuit interrupter If treating the entire house install the disinfection system before any branch lines A 5 micron sedi...

Page 5: ...he power source check all connections to ensure that they are indeed secure turn on water supply and check for any leaks If satisfied that there are no leaks proceed with the followings steps DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE DISINFECTION SYSTEM THIS COULD DAMAGE THE O RING SEALS 5 To properly ground the stainless steel reactor chamber attach the green wire coming from the power sour...

Page 6: ...ration 3000C with 1 GPM Ultraviolet Water Sterilizer System CQE RO 00103 Point of Use Bottleless Water Cooler with 1 GPM Ultraviolet Water Sterilizer System CQP WC 05901 MODEL WATTS ELECTRICAL VOLTS ELECTRICAL Hz OUTPUT POWER HOUSING MATERIAL SS DOSAGE uW cm2 INLET OUTLET PORT SIZE MNPT AUDIBLE LAMP FAILURE MAXIMUM PRESSURE LBS CQE UV 00101 1 GPM 11W 110 240 50 60 50mA 304 30000 YES 85 CQE UV 0010...

Page 7: ...eeve with a cloth soaked in vinegar or some other mild acid and then rinse 6 Reassemble to quartz sleeve in the UV chamber allowing the sleeve to protrude an equal distance from both ends of the UV chamber 7 Wet the O rings and slide onto each end of the quartz sleeve then reassemble the gland nuts hand tight is sufficient 8 Retighten all connections turn on water and check for leaks 9 Reinstall t...

Page 8: ...equired during or after the warranty period or should you have any questions regarding how to use your CRYSTAL QUEST UltraViolet Disinfection System please contact our Technical Support Department at service crystalquest com Monday through Friday 9 AM to 5 PM Eastern Time KEEP THIS MANUAL FOR FUTURE REFERENCE AND UNIT MAINTENANCE Online warranty information http crystalquest com warranty htm Produ...

Reviews: