background image

KCR535
KCR835

Caravaggio

HOOD

Pre-installation and installation manual

Summary of Contents for Caravaggio KCR535

Page 1: ...KCR535 KCR835 Caravaggio HOOD Pre installation and installation manual ...

Page 2: ...en 8 Caravaggio KCR535 hood technical data hood triple oven 9 Caravaggio KCR835 hood technical data hood single oven 10 Caravaggio KCR835 hood technical data hood double oven 11 Caravaggio KCR835 hood technical data hood triple oven 12 3 INSTALLATION 13 Transport 14 Preliminary operations 14 Serial number plate reading 14 Positioning and connection to the oven below 15 Wiring diagrams 17 Smoke ext...

Page 3: ... and suitable to cooking food has adequate air ventilation complies with the current regulations on health and safety and systems in the workplace is protected from the weather has a maximum temperature of between 5 41 F and 35 C 95 F has a maximum humidity of 70 between the hood and the ceiling there is a distance of about 600 mm 24 in shorter distances could damage ceilings made of particularly ...

Page 4: ...t system can be installed in neutral versions Fig 3 The following must be installed during installation the pipe A supplied by the Manufacturer the connection B supplied by the Manufacturer a flue D blocking it with a metallic clamp C NEITHER supplied by the Manufacturer The flue must be exclusively used by the equipment have a 150 mm Ø5 91 in diameter to guarantee correct draught up to a maximum ...

Page 5: ...0 Maximum absorption kW max 0 0072 0 13 Connection cable n x mm2 Installed cable type EU version 3x1 mm2 silicone cable H07RN Fthree polecable for single phase cabling Installed cable section UL CSA version 16 3 cable UL AWM Style 3644 Maximum capacity m3 h 700 A Oven supply input B Equipotential C Circuit breaker only for American market D Hood supply input E Oven smoke exhaust F Extraction fan G...

Page 6: ...with ISO 5810 Sound pressure level dB A Extraction Expulsion Radiated 59 56 42 Sound pressure level measured in free field at 1 5 meters at maximum air volu me 0 100 200 300 400 500 600 700 0 100 200 300 400 0 10 20 30 40 0 100 200 300 400 500 600 700 20 40 60 80 1 4 0 V 1 7 0 V 230V 140V 170V 230V 500 600 700 8 0 0 1 0 0 0 1 2 0 0 qv m3 h qv m3 h P W psf Pa psf mmcda CARAVAGGIO hood technical dat...

Page 7: ...69 0in 1175mm 46 2in 50mm 2 0in 107 5mm 4 2in 60mm 2 4in 5 9 8 m m 2 3 5 i n 8 0 8 m m 3 1 8 i n 5 5 m m 2 2 i n 147mm 5 8in 80mm 3 1in 875mm 34 4in 144 5mm 5 7in 383 5mm 15 1in 528mm 20 8in 215mm 8 5in 340mm 13 4in 78 5mm 3 1in 144 5mm 5 7in 170mm 6 7in 383 5mm 15 1in 219mm 8 6in 528mm 20 8in 171mm 6 7in 220mm 8 7in 624mm 24 6in 505mm 19 9in Caravaggio KCR535 hood technical data hood single oven ...

Page 8: ...47mm 13 7in 60mm 2 4in 107 5mm 4 2in 5 9 8 m m 2 3 5 i n 8 0 8 m m 3 1 8 i n 5 5 m m 2 2 i n 147mm 5 8in 80mm 3 1in 875mm 34 4in 144 5mm 5 7in 383 5mm 15 1in 528mm 20 8in 215mm 8 5in 340mm 13 4in 78 5mm 3 1in 144 5mm 5 7in 170mm 6 7in 383 5mm 15 1in 219mm 8 6in 528mm 20 8in 171mm 6 7in 220mm 8 7in 624mm 24 6in 505mm 19 9in Caravaggio KCR535 hood technical data hood double oven ...

Page 9: ...4 59in 624 5mm 13 66in 347mm 1 97in 50mm 16 91in 429 5mm 2 36in 60mm 4 24in 107 5mm 5 9 8 m m 2 3 5 i n 8 0 8 m m 3 1 8 i n 5 5 m m 2 2 i n 147mm 5 8in 80mm 3 1in 875mm 34 4in 144 5mm 5 7in 383 5mm 15 1in 528mm 20 8in 215mm 8 5in 340mm 13 4in 78 5mm 3 1in 144 5mm 5 7in 170mm 6 7in 383 5mm 15 1in 219mm 8 6in 528mm 20 8in 171mm 6 7in 220mm 8 7in 624mm 24 6in 505mm 19 9in Caravaggio KCR535 hood techn...

Page 10: ...2 4in 1175mm 46 2in 50mm 2 0in 5 9 8 m m 2 3 5 i n 8 0 8 m m 3 1 8 i n 5 5 m m 2 2 i n 147mm 5 8in 80mm 3 1in 875mm 34 4in 144 5mm 5 7in 383 5mm 15 1in 528mm 20 8in 215mm 8 5in 340mm 13 4in 78 5mm 3 1in 144 5mm 5 7in 170mm 6 7in 383 5mm 15 1in 219mm 8 6in 528mm 20 8in 171mm 6 7in 220mm 8 7in 624mm 24 6in 505mm 19 9in Caravaggio KCR835 hood technical data hood single oven ...

Page 11: ... 60mm 2 4in 973mm 38 4in 347mm 13 7in 50mm 2 0in 107 5mm 4 2in 5 9 8 m m 2 3 5 i n 8 0 8 m m 3 1 8 i n 5 5 m m 2 2 i n 147mm 5 8in 80mm 3 1in 875mm 34 4in 144 5mm 5 7in 383 5mm 15 1in 528mm 20 8in 215mm 8 5in 340mm 13 4in 78 5mm 3 1in 144 5mm 5 7in 170mm 6 7in 383 5mm 15 1in 219mm 8 6in 528mm 20 8in 171mm 6 7in 220mm 8 7in 624mm 24 6in 505mm 19 9in Caravaggio KCR835 hood technical data hood double...

Page 12: ...6 91in 429 5mm 2 36in 60mm 4 20in 107 5mm 1 97in 50mm 5 9 8 m m 2 3 5 i n 8 0 8 m m 3 1 8 i n 5 5 m m 2 2 i n 147mm 5 8in 80mm 3 1in 875mm 34 4in 144 5mm 5 7in 383 5mm 15 1in 528mm 20 8in 215mm 8 5in 340mm 13 4in 78 5mm 3 1in 144 5mm 5 7in 170mm 6 7in 383 5mm 15 1in 219mm 8 6in 528mm 20 8in 171mm 6 7in 220mm 8 7in 624mm 24 6in 505mm 19 9in Caravaggio KCR835 hood technical data hood triple oven ...

Page 13: ...te provides important technical information This is vital in case of a request for maintenance or repair of the equipment please do not remove damage or modify it Failure to follow these regulations may cause damage or even fatal injury subsequently invalidating the guarantee and relieving the Manufacturer of all liability The company cannot be held liable for any print or transcription errors res...

Page 14: ...ve or abrasive products or sharp or pointed instruments Check that all the parts making up the hood are in good condition and without any faults or breakages if that is not the case contact the Dealer for the procedures to follow Serial number plate reading Fig 6 The serial number is on the back of the appliance It provides important technical information that is vital in case of a request for mai...

Page 15: ...gio oven Fig 7 Disconnect the power supply from the oven to which the hood will be connected Fix the hood to the oven below acting as shown in the figure Make sure that between the hood and the ceiling there is a dis tance of about 600 mm 24 in shorter distances could dam age ceilings made of particularly delicate and heat sensitive materials e g wood Fig 8 Open the side compartment to gain access...

Page 16: ...gh the hole you took the cap off previously T Block the cable with the locknut D Insert the male connector K of the hood into the female con nector P connected to the oven terminal board If required the cable can be replaced by the Dealer or its technical service or by a person with similar qualifica tions to prevent any risk Installed cable type EU version 3x1 mm2 silicone cable H07RN F three pol...

Page 17: ... WAGO 2 way mod 221 L N L TR Wiring diagrams EU version Abbreviation Description M Hood motor C Motor start capacitor CTRL Speed variation board L LEDs TR LED transformer Installed cable type 3x1 mm2 silicone cable H07RN F three pole cable for single phase cabling brown blue brown blue black yellow green yellow green yellow green blue blue brown brown Suction hood Neutral hood ...

Page 18: ... UL AWM Style 3644 Wiring diagrams UL CSA version Abbreviation Description M Hood motor not supplied S Connector CTRL Control board L LEDs TR LED transformer Installed cable section 16 3 cable UL AWM Style 3644 Neutral hood Supply from the oven ...

Page 19: ...e user s exhaust system can be installed in neutral versions Fig 11 The pipe A and connection B both supplied by the Manu facturer must be installed during installation Fig 12 It is then necessary to install a flue D blocking it with a metal clamp C neither is supplied by the Manufacturer The flue D must be exclusively used by the equipment have a 150 mm Ø5 91 in diameter to guarantee correct drau...

Page 20: ...rect Checking the operation Start the appliance following the instructions in the Use and Maintenance manual monitor it during the whole test and check that all the electrical components work properly Finish off explaining to the user how to use the appliance in an optimal and safe way and how to carry out ordinary mainte nance and cleaning Positioning checks Reference chapter on page Has the prot...

Page 21: ......

Page 22: ...CUPPONE 1963 Cuppone F lli S r l Via Sile 36 31057 Silea TV ITALY T 39 0422 361143 F 39 0422 360993 info cuppone com www cuppone com ...

Reviews: