background image

 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR650ELCD / BR850ELCD / BR1000ELCD / BR1200ELCD 

User’s Manual 

  K01-C0000108-01 

 

 

 

This manual contains important instructions that should be followed during installation and maintenance of 
the UPS and batteries. Please read and follow all instructions carefully during installation and operation of 
the unit. Read this manual thoroughly before attempting to unpack, install, or operate. 

CAUTION! 

The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker 

protection. 

DO NOT

 plug the UPS into an outlet that is not grounded. If you need to de-energize this 

equipment, turn off and unplug the UPS. 

CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! 

CyberPower Systems does 

not sell products for life support or medical applications. 

DO NOT

 use in any circumstance that would affect 

the operation or safety of any life support equipment, with any medical applications, or patient care. 

CAUTION! 

Hazardous live parts inside can be energized by the battery even when the AC input power is 

disconnected. 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor 

area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity 
range). 

CAUTION! 

To reduce the risk of electric shock, do not remove the cover, except to service the battery. There 

are no user serviceable parts inside, except for the battery. 

CAUTION! 

To avoid electrical shock, turn off the unit and unplug it from the AC power source before 

servicing the battery or installing a computer component. 

CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! 

To reduce the risk of fire, do not use with or near 

aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause 
the machine to short out. 

CAUTION! DO NOT USE WITH LASER PRINTERS! 

The power demands of laser printers are too large for 

a UPS. 

 
 

 

 

UNPACKING 

 
The box should contain the following: 
(1) UPS Unit x 1; (2) Phone Line x 1; (3) USB Cable x 1; (4) User Manual x 1; (5) Cable Collector x 1; 
(6) Warranty Card x 1; 
*PowerPanel® Personal Edition software is available on our website. Please visit 

www.cyberpower.com

 and 

go to the Software Section for free download. 
 

OVERVIEW

 

 
The BR650ELCD/ BR850ELCD/ BR1000ELCD/ BR1200ELCD provides automatic voltage regulation for 
inconsistent utility power. The BR650ELCD/ BR850ELCD/ BR1000ELCD/ BR1200ELCD features 125 Joules 
of surge protection, and provides battery backup during power outages. The BR650ELCD/ BR850ELCD/ 
BR1000ELCD/ BR1200ELCD ensures consistent power to your computer system and its included software 
will automatically save your open files and shutdown your computer system during a utility power loss. 
 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 

1.

  Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral 

equipment does not exceed 650VA/850VA/1000VA/1200VA.   

2.

  Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the 

UPS unit's rated capacity (650VA/390W forBR650ELCD, 850VA/510W for BR850ELCD,1000VA/600W 
for BR1000ELCD, 1200VA/720W for BR1200ELCD). If the rated unit capacities are exceeded, an 
overload condition may occur and cause the UPS unit to shut down and the circuit breaker to trip. 

 

HARDWARE INSTALLATION GUIDE 

 
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 

hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss 
may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC 
outlet. The unit will charge in both the on and off position. 

2. If you will use the software, connect the USB cable to the USB port on the UPS. 
3. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data 

storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power supplied outlets. 

DO NOT 

plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device 
into the UPS. The power demands of these devices will overload and possibly damage the unit.

 

4. To protect a fax, telephone, modem line or network cable, connect a telephone cable or network cable 

from the wall jack outlet to the IN jack of the UPS. Then connect a telephone cable or network cable from 
the OUT jack on the UPS to the modem, computer, telephone, fax machine, or network device. 

5. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is 

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. 
air conditioner, refrigerator, copier, etc.) Avoid using extension cords. 

6. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will 

"beep". 

7. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, 

turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 
10 seconds. Make sure the circuit breaker is depressed and then turn the UPS on. 

8. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the 

battery will automatically recharge. 

9. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
10. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the 

battery every three months to ensure battery life. 

 

 

 

 
DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.  Power Switch 

Press the switch for two seconds to turn the UPS ON or OFF. 

2.  LCD Display Selected Switch 

The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and 
Estimated Run Time. The toggle frequency is set to one time per second. Holding the switch for more than 
two seconds while running on battery will silence the buzzer. 

3.  LCD Display 

High resolution and intelligent LCD display shows all the UPS information with icons and messages. For 
more information please review the “Definitions for Illuminated LCD Indicators” section. 

4.  Communication Protection Ports RJ11/RJ45 

Communication protection ports will protect any standard modem, fax, telephone line, or network cable from 
surge and spikes. 

5.  AC Outlets 

The UPS provides 4 outlets for connected equipment to insure temporary uninterrupted operation during a 
power failure and against surges and spikes and another 4 outlets against surges and spikes only. 

6.  USB Charger Port 

The UPS provides charging for external equipment via this port. 

7.  Cable Collector 

Collect the cables connected from the AC outlets in the cable collector. 

8.  Led Indicators 

The power on LED lights up when the UPS is ON. 

9.  USB Port To PC 

This port allows connection and communication from the USB port on the computer to the UPS unit. The 
UPS communicates its status to the 

PowerPanel® Personal Edition

 software. 

10. Input Circuit Breaker 

The Circuit Breaker provides optimal overload protection. 

11. Input Power Cord 

Connect to utility power 

 

 

 

 

Model 

 

BR650ELCD-UK 

BR850ELCD-UK 

BR1000ELCD-UK 

BR1200ELCD-UK

 

Capacity (VA) 

650VA 

850VA 

1000VA 

1200VA 

Capacity (Watts) 

390W 

510W 

600W 

720W 

Input

 

Input Voltage Range 

165-290Vac 

Frequency Range 

47~63Hz (Auto Sensing) 

AVR Function 

Boost @ 200+/-10V 

Output

 

On Battery Output Voltage 

Simulated Sine Wave at /-10% 

On Battery Output Frequency 

50/60Hz +/-1% 

Transfer Time 

4ms Typical 

Overload Protection 

On Utility: Circuit Breaker and Internal Current Limiting 

On Battery: Internal Current Limiting 

Surge Protection

 

Lightning / Surge Protection 

Yes 

Network/ Phone/ Fax/ Modem 
Protection 

RJ11/RJ45 (One In/ One Out) 

Operating Temperature 

+32

°

F to 104

°

F ( 0

°

C to 40

°

C ) 

Physical

 

Total # of UPS outlets 

6 (3 for battery backup and surge, 3 for surge only) 

Dimensions (WxHxD) (mm) 

166x 118x288 

Weight (kg) 

5.3 

6.5 

6.5 

8.2 

Wall-mounted Distance(mm) 

163 

Battery

 

Sealed Maintenance Free 
Lead Acid Battery 

RBP0083 x 1 

RBP0006 x 1 

RBP0063 x 2 

Typical Recharge Time 

8 hours 

User Replaceable 

Yes 

Status Indicators 

Indicators 

Power On, LCD Display 

Audible Alarms 

On Battery, Low Battery, Overload 

Communication

 

PowerPanel

®

 Personal Edition 

Software 

Windows 8/7/Vista/XP/2000,Server 2012/2008/2003, Linux 

Management

 

Auto-Charger 

Yes 

Auto-Restart 

Yes 

USB interface 

Yes 

 

 

TECHNICAL SPECIFICATIONS 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

IMPORTANT SAFETY INSTRUCTIONS 

Reviews: