background image

 

 
 
       
 

 

 

 

CP900AVR / BC900 

CP1200AVR / BC1200 
CP1500AVR / BC1500 

User’s Manual   

K01-BC00000

 

IMPORTANT SAFETY WARNINGS 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the 

unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!  

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!  

To reduce the risk of electric shock, do not remove the cover except to service the battery.    No user serviceable parts inside 

except for battery. 

CAUTION!  

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!  

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!  

To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 

computer component. 

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!   

CyberPower Systems does not sell products for life support or medical 

applications.  

DO NOT

 use in any circumstance that would affect operation or safety of any life support equipment or with any medical 

applications or patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation from the aquarium can cause the unit to short out. 

DO NOT USE WITH LASER PRINTERS!   

The power demands of these devices will overload and possibly damage the unit. 

 

INSTALLING YOUR UPS SYSTEM   

 
 

UNPACKING 

 
Inspect the UPS upon receipt. The box should contain the following: 

(1) UPS unit; (1) User’s manual; (1) PowerPanel™ Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 

registration card; (1) Coaxial Cable (Coaxial Cable is not included in CPS900AVR / BC900) 

 

WHAT IS AVR?

 

 

The

 

CP900AVR / BC900 CP1200AVR / BC1200 CP1500AVR / BC1500 provide complete 

power protection from utility power that is not always consistent.  The CP900AVR / BC900 

features 890 Joules and CP1200AVR / BC1200 CP1500AVR / BC1500 features 1080 Joules of 

surge protection, and provide long lasting battery backup with 7.2AH * 2 / 8AH * 2 / 9AH * 2 

batteries for loss of utility power and voltage sags.   The CP900AVR / BC900 CP1200AVR / 

BC1200 CP1500AVR / BC1500 ensure consistent power to your computer system and include 

software that will automatically save your open files and shutdown your computer system during 

a utility power loss. 

 

AUTOMATIC VOLTAGE REGULATOR

 

 

The

 

CP900AVR / BC900 CP1200AVR / BC1200 CP1500AVR / BC1500

 

stabilize utility power voltage levels that are inconsistent.    The 

excessive incoming utility power may be damaging to important data files, but with Automatic Voltage Regulation,

 

the computer will not 

experience damaging voltage levels.    An Automatic Voltage Regulator automatically increases low voltage to a consistent, computer safe 

110v/120v.    The unit’s powerful 7AH / 8AH / 9AH batteries will provide power only if the incoming voltage drops below 88v or increases 

above 140v. 

HARDWARE INSTALLATION GUIDE 

 

1.  Your new UPS may be used immediately upon receipt.    However, 

recharging the batteries for at least 16 hours

 is recommended to 

insure that the battery’s maximum charge capacity is achieved.    A loss of charge may occur during shipping and storage.    To recharge 

the batteries, simply leave the unit plugged into an AC outlet.    The unit will charge in both the ON as well as the OFF position. 

2.  With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data storage device (Zip drive, Jazz 

drive, Tape drive, etc…) into the battery power supplied outlets.    Plug your peripheral equipment (printer, scanner, speakers) into the 

full-time surge protection outlets.   

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum or other large 

electrical device into the UPS.    The power demands of these devices will overload and possibly 

damage the unit. 

3.  To surge protect a network connection, connect a network cable from the wall jack outlet to the IN jack of the 

UPS. Then connect a network cable from the OUT jack on the UPS to the network device. 

4.  Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).    Make sure the wall branch outlet is protected by a fuse or circuit 

breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc…).    The warranty prohibits the use 

of extension cords, outlet strips, and surge strips. 

5.  Press the power switch to turn the unit on.    The power on indicator light will illuminate and the unit will “beep” once. 

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug 

at least one piece of equipment from the battery power supplied outlets.    Wait 10 seconds.    Make sure the circuit breaker is depressed 

and then turn the UPS on. 

7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

8.  To store your UPS for an extended period, cover it and store with the battery fully charged.    While in storage recharge the battery every 

three months to insure battery life. 

 

BASIC OPERATION 

 

DESCRIPTION 

 

 

Power Switch 

Can be used as a master on/off switch for equipment connected to the battery power supplied outlets. 

Power On Indicator 

This LED is illuminated when the utility condition is normal and the UPS 

outlets are providing power, free of surges. 

Using Battery Indicator 

This LED is illuminated when the unit is providing battery backup power. 

AVR Indicator 

This LED is illuminated when the unit is running in the AVR mode. 

Over Load Indicator 

This LED is illuminated when the unit is overloaded.    You will need to reduce the load. 

Battery and Surge Protected Outlets 

The unit has four battery powered/surge protected outlets for connected equipment and ensures 

temporary uninterrupted operation of your equipment during a power failure. 

Full-Time Surge Protection Outlets 

The unit has four always on surge suppression outlets. 

Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 

this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is 

properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet connection.

 

 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.   

 

Serial/USB Ports to PC 

The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit.    The UPS 

communicates its status to the PowerPanel™ Personal Edition software.    This interface is also compatible with Power Management 

provided by Windows

R

 2000 and Windows

R

 XP. 

Note: Only one of these two ports can be used to communicate with your computer at one time. 

Note: To install PowerPanel™ Personal Edition Software the computer will need Microsoft

R

  Internet Explore 5.0 or higher 

installed. 

Note: If using the Serial Port, users need to download Power Panel

R

  software 

 

 

 

Coax/Cable/DSS Surge Protection 

The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.

 

 

Outlets Designed for AC Adapters 

The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 

 

REPLACING THE BATTERY   

 

CAUTION!  

Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.    Service the battery under the 

supervision of personnel knowledgeable of batteries and their precautions. 

CAUTION!

    Use only the specified type of battery.    See your dealer for replacement batteries.

 

CAUTION!  

The battery may present a risk of electrical shock.    Do not dispose of battery in a fire as it may explode. Follow all local 

ordinances regarding proper disposal of batteries.    Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as 

required by most state laws. 

CAUTION!

    Do not open or mutilate the batteries.    Released electrolyte is harmful to skin and eyes and may be toxic.

 

CAUTION!  

A battery can present a high risk of short circuit current and electrical shock.    Take the following precautions before replacing 

the battery: 

 

REMINDER:  

Batteries are consider 

HAZARDOUS WASTE

 and must be disposed of properly.    Almost any retailer that sells lead-acid 

batteries collects used batteries for recycling, as required by most state laws. 

 

 

TROUBLE SHOOTING 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has tripped due to an 
overload. 

Turn the UPS off and unplug at least one piece of equipment.   
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on.

 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

The UPS does not perform 
expected runtime. 

Battery is slightly worn out. 

Contact CyberPower Systems about replacement batteries

 

The on/off switch is designed to 
prevent damage by rapidly turning it 
off and on. 

Turn the UPS off.    Wait 10 seconds and then turn the UPS on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 110/120v 60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries

 

The UPS will not turn on. 
 

Mechanical problem. 

Contact CyberPower Systems

The USB / serial cable is not 
connected. 

Connect the USB / serial cable to the UPS unit and an open 
USB / serial port on the back of the computer.    You must use 
the cable that came with the unit. 

The USB / serial cable is connected 
to the wrong port. 

Check the back of the computer for an additional USB / serial 
port.    Move the cable to this port. 

The unit is not providing battery 
power. 

Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the unit. 

PowerPanel™ Personal Edition 
is inactive (all icons are gray). 

The serial cable is not the cable that 
was included with the UPS unit. 

If you are using a serial cable you must use a CyberPower serial 
cable.    If you need this cable please contact technical support.   

 

 

 

TECHNICAL SPECIFICATIONS 

 

Model 

CP900AVR / BC900 

CP1200AVR / BC1200 

CP1500AVR / BC1500 

Capacity 

800VA / 560W 

1200VA / 720W 

1500VA / 900W 

Input Voltage on Utility 

88V to 140V 

Input Frequency 

47 Hz to 63 Hz 

On-Battery Output Voltage 

120Vac ± 5% 

Transfer Time 

4ms Typical 

Max. Load for UPS Outlets 

800VA / 560W 

1200VA / 720W 

1500VA / 900W 

Max. Load for Full-Time Surge Protection outlets (8 Outlets) 

12 Amps 

On-Battery Output Wave Form 

Simulated Sine Wave Form 

Operating Temperature 

+ 32°F to 104° F / 0° C to 40° C 

Operating Relative Humidity 

0 to 95% NON-CONDENSING 

Size (L x W x H) 

13 1/4” x 4” x 9 7/8” 

33.6 x 10.0 x 24.9cm 

12 3/4” x 3 1/2” x 14 1/2” 

32.5 x 8.8 x 37.2cm 

Net Weight 

20.9 lbs 

21.8 lbs 

26.6 lbs 

Typical Battery Recharge Time 

8 hours typical from total discharge 

Typical Battery Life 

3 to 6 years, depending on number of discharge/recharge cycles 

Battery Type 

12V / 7.2AH x 2 

12V / 8.0AH x 2 

12V / 9.0AH x 2 

Recommended Battery 

Spill-proof, Maintenance-free, sealed lead-acid 

Safety Approvals 

UL1778(UPS), cUL107., FCC/DoC Class B 

 

EXPECTED RUNTIME IN MINUTES 

(Due to the differences in computer components, the runtime will vary.) 
 

Model 

iMac G4 

Desktop PC with LCD 

Monitor 

Desktop PC 

  with 15” Monitor 

Desktop PC 

  with 17” Monitor 

Desktop PC 

  with 21” Monitor 

CP900AVR 

BC900 

105 minutes 

75 minutes 

60 minutes 

40 minutes 

35 minutes 

CP1200AVR 

BC1200 

145 minutes 

90 minutes 

66 minutes 

50 minutes 

42 minutes 

CP1500AVR 

BC1500 

170 minutes 

100 minutes 

75 minutes 

58 minutes 

48 minutes 