FEATURES 

1. Power Switch
2. Power On Indicator
3. LCD Module Display
4. LCD Toggle / Selected Switch
5. USB Charging Ports
6. Battery and Surge Protected Outlets
7. Full-Time Surge Protection Outlets

8. Circuit Breaker
9. USB Ports to PC
10. Communication Protection Ports
11. Wiring Fault Indicator (red)
12. Coax / Cable / DSS Surge Protection
13. Widely-Spaced Outlets Designed

for AC Adapters

Cyber Power Systems (USA), Inc. 

4241 12th Avenue East, Suite 400  |  Shakopee, MN 55379  | 

CyberPowerSystems.com 

Summary of Contents for CST150XLU

Page 1: ...harging Ports 6 Battery and Surge Protected Outlets 7 Full Time Surge Protection Outlets 8 Circuit Breaker 9 USB Ports to PC 10 Communication Protection Ports 11 Wiring Fault Indicator red 12 Coax Cable DSS Surge Protection 13 Widely Spaced Outlets Designed for AC Adapters Cyber Power Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 CyberPowerSystems com ...

Page 2: ...ircuit breaker protection Do not plug into an outlet that is not grounded If you need to de energize this equipment turn of and unplug the unit CAUTION To avoid electric shock turn of the unit and unplug it from the AC power source before connecting equipment to the unit CAUTION To reduce the risk of fre connect only to a circuit provided with 20 amperes maximum branch circuit over current protect...

Page 3: ...tem performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended that you charge the battery for at least 8 hours Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery ...

Page 4: ...ports provide 5V 2 1A power output 6 Battery and Surge Protected Outlets The UPS has fve battery powered surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical devices into the Battery and Surge Protected Outlets T...

Page 5: ...lug it from the AC power source 3 Turn the UPS on its side 4 Remove two retaining screws located on the bottom of the UPS 5 Slide the battery compartment cover completely of of the unit 6 Remove the battery which is located on the right side from the compartment 7 Disconnect the battery wires from the right side of the battery 8 Slide the remaining battery from left to right and remove it from the...

Page 6: ...erpowersystems com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The USB cable is not connected Connect the USB cable to the UPS unit and an open USB port on the back of the computer You must use the cable that came with the unit PowerPanel Personal is inactive all icons are gray The USB cable is connected to the wrong port Check the back of the computer fo...

Page 7: ...c Voltage Regulation Icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no action is required on your part 7 SILENT MODE Icon This icon appears whenever the UPS is in silent mode The buzzer does not beep during silent mode until the battery reaches low capacity The LCD display ind...

Page 8: ...ets 12 Amps On Battery Output Wave Form Simulated Sinewave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Size W x H x D 3 9 in 9 8 in 13 7 in Net Weight 25 0 lbs 11 3 kg Battery Type CyberPower RB1290X2 Typical Battery Recharge Time 8 hours to 90 capacity from total discharge Typical Battery Life 3 to 6 years depending on number of discharge rec...

Page 9: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit diferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifcations...