K01-0000114-00

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DX400E-DE / DX600E-DE / DX800E-DE 

User’s Manual 

 

 
 

 

 

 

Summary of Contents for DX400E-DE

Page 1: ...K01 0000114 00 DX400E DE DX600E DE DX800E DE User s Manual ...

Page 2: ...de CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out CAUTION DO NOT USE WITH LASER PRINTERS The powe...

Page 3: ...mains during battery mode Refer to Definitions for Illuminated LED Indicators section for details AC outlet The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes USB Port to PC This port allows connection and communication from the USB port on the computer to the UPS unit The UPS communicates its status t...

Page 4: ...e long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 7 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 8 To maintain optimal battery charge leave the UPS plug...

Page 5: ...ing every 1 2 second Utility Failure The UPS is providing battery power Rapid beeping indicates the unit will run out of power shortly Fault Constant Tone Battery Overload Occurs when connected equipment exceeds the listed capacity of the UPS Turn the UPS off unplug at lease one piece of equipment from battery outlets reset the circuit breaker and turn the unit on Battery Capacity OFF 3 LED 75 100...

Page 6: ...ection Lightning Surge Protection Yes Physical Total of UPS outlets 3 Battery Backup Surge Protected Outlets Maximum Dimensions LxWxH 235 x 90 x 190mm Weight kg 2 7 3 4 3 9 Battery Sealed Maintenance Free Lead Acid Battery 12V 4 5Ah x1 12V 7Ah x1 12V 8 5Ah x1 Typical Recharge Time 8 hours Status Indicators Indicators Using AC Using Battery Fault Battery Capacity Audible Alarms On Battery Low Batte...

Page 7: ... replacement batteries at service cyberpower eu com The UPS will not turn on Mechanical problem Contact CyberPower Systems at service cyberpower eu com The USB cable is not connected Connect the USB cable to the UPS unit and an open serial port on the back of the computer You must use the cable that came with the unit PowerPanel Personal Edition is inactive The unit is not providing battery power ...