GX1500U 

User’s Manual 

K01-0000844-00 

 

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at 

www.cyberpowersystems.com/registration/. Registration certifies your product's warranty, confirms your 

ownership in the event of a product loss or theft and entitles you to free technical support. Register your 

product now to receive the benefits of CyberPower ownership. 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during 

installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or 

operate your UPS. 

CAUTION!    To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area free of conductive contaminants.    (Please see specifications for acceptable temperature and 

humidity range). 

CAUTION!    To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn 

off and unplug the unit before servicing the batteries. There are no user serviceable parts inside except for 

the battery. 

CAUTION!    Hazardous live parts inside can be energized by the battery even when the AC input power is 

disconnected. 

CAUTION!    The UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do 

not plug into an outlet that is not grounded.    If you need to de-energize this equipment, turn off and unplug 

the unit. 

CAUTION!    To avoid electric shock, turn off the unit and unplug it from the AC power source before 

servicing the battery or installing a computer component. 

CAUTION!    Not for use in a computer room as defined in the Standard for the Protection of Electronic 

Computer/Data Processing Equipment, ANSI/NFPA 75. 

CAUTION!    To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch 

circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70. 

CAUTION!    DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!    DO NOT use in any 

circumstance that would affect the operation and safety of life support equipment, medical applications, or 

patient care. 

CAUTION!    DO NOT USE WITH OR NEAR AQUARIUMS!    To reduce the risk of fire or electric shock, do not 

use with or near an aquarium.    Condensation from the aquarium can cause the unit to short out. 

CAUTION!    DO NOT USE THE UPS ON ANY TRANSPORTATION!    To reduce the risk of fire or electric shock, 

do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused 

during transit and the damp environment can cause the unit to short out. 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: (a) UPS unit (b) User’s manual (c) USB 

A+B type cable (d) Function Setup Guide 

*PowerPanel®  Personal software is available on our website. Please visit www.cyberpower.com and go to the 

Software Section for free download. 

SUPPORTS ACTIVE PFC POWER SUPPLIES 

This CyberPower UPS system delivers sine wave output, which is ideal for seamless operation of computers 

using high efficiency switching power supplies with Active Power Factor Correction (Active PFC), home 

entertainment systems, and other sensitive electronics. 

OVERVIEW 

The GX1500U provides complete power protection from utility power that is not always consistent. The 

GX1500U features 1445 Joules of surge protection. The unit provides long lasting battery backup during 

power outages with maintenance free batteries. The GX1500U ensures consistent power to your computer 

system and includes software that will automatically save your open files and shutdown your computer 

system during a utility power loss. 

SYSTEM BLOCK DIAGRAM 

 

AUTOMATIC VOLTAGE REGULATOR 

The GX1500U uses Automatic Voltage Regulation (AVR) to stabilize inconsistent utility power voltage to 

levels that are safe for connected equipment. AVR safeguards hardware and important data files by 

automatically increasing low utility power to a consistent and safe output voltage while preserving battery 

power for outages.   

DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.

 

Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity 

(1500VA/900W for GX1500U). If the rated capacities of the unit are exceeded, an overload condition 

may occur and cause the UPS unit to shut down or the circuit breaker to trip. 

2.

 

There are many factors that can affect the amount of power that your computer system will require.   

It is suggested that the load placed on the battery outlets not exceed 80% of the unit’s capacity. 

HARDWARE INSTALLATION GUIDE

 

1.

 

Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure 

the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 

hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, 

the battery will automatically charge whether the UPS is turned on or off. Note: This UPS is designed 

with a safety feature to keep the system from being turned on during shipment. The first time you turn 

the UPS on, you will need to have it connected to AC power or it will not power up. 

2.

 

With the UPS unit turned off and unplugged, connect your computer, monitor, and any other 

peripherals requiring battery backup into the battery power supplied outlets. DO NOT plug a laser 

printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical devices 

into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload 

and damage the unit. 

3.

 

Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the 

wall branch outlet is protected by a fuse or circuit breaker and does not service 

equipment with large electrical demands (e.g. air conditioner, copier, etc…). The 

warranty prohibits the use of extension cords, outlet strips, and surge strips.

 

 

4.

 

Press the power switch to turn the unit on. The Power On indicator light will 

illuminate and the unit will “beep”. If an overload is detected, an audible alarm will sound and the unit 

will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment 

from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the 

UPS on. 

5.

 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

6.

 

To store the UPS for an extended period, cover it and store with the battery fully charged.    While in 

storage, recharge the battery every three months to ensure battery life. 

7.

 

Ensure the wall outlet and UPS are located near the equipment being attached for proper 

accessibility. 

 

 

1

 

Power Switch: Used as the master on/off 

switch for equipment connected to the 

battery power supplied outlets. 

2

 

Power On Indicator: This LED is illuminated 

when the utility power is normal and the 

UPS outlets are providing power, free of 

surges and spikes.   

3

 

LCD module display: High resolution and 

intelligent LCD display shows all the UPS 

information using icons and messages.   

For more information please review the 

“Definitions for Illuminated LCD Indicators” 

section below. 

4

 

Down/Display button: The button can be 

used to select the LCD display contents 

including Input Voltage, Output Voltage, 

and Estimated Run Time. Short press the 

button to scroll down the function menu. 

Pressing the button for 2 seconds will keep 

the LCD display always on or turn the LCD 

display off while in AC/Utility power mode. 

For more information about the 

Down/Display Button, please refer to the 

Function Setup Guide

5

 

Up/Mute button: Short press the button to scroll up the function menu. Holding the button for more 

than 2 seconds will silence the alarm. For more information about the Up/Mute Button, please refer to 

the 

Function Setup Guide

6

 

Enter/Setup Button: Press the button for 2 seconds to enter the setup menu and then select the 

functions for configuration. For more information about the Enter/Setup Button, please refer to the 

Function Setup Guide

7

 

USB Charging Ports: The USB charging ports (Type A and Type C) provide DC 5V 3.1A power output 

with battery backup. 

8

 

Battery and Surge Protected Outlets: The unit has 6 battery powered/surge suppression outlets for 

connected equipment to ensure temporary uninterrupted operation of your equipment during a 

power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump 

or other large electrical devices into the “Battery and Surge Protected Outlets”. The power demands 

of these devices may overload and damage the unit.) 

9

 

Full-Time Surge Protected Outlets: The unit has 6 surge suppression outlets. 

10

 

Circuit Breaker: Located on the back of the UPS, the circuit breaker serves to provide overload and 

fault protection.   

11

 

Serial/USB Ports to PC: The USB port allows connection and communication between the USB port 

on the computer and the UPS unit. 

12

 

Wiring Fault Indicator (red): This LED indicator will illuminate to warn the user that a wiring problem 

exists, such as bad ground, missing ground or reversed wiring.    If this is illuminated, disconnect all 

electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The 

unit will not provide surge protection without being plugged into a grounded and properly wired wall 

outlet. 

13

 

Communication Protection Ports (RJ45): Bi-directional communication ports provide surge 

protection to a 10/100/1000 Ethernet connection. 

14

 

Outlets Designed for AC Adapters: The unit has 2 outlets spaced to allow AC power adapter blocks to 

be plugged into the UPS without blocking adjacent outlets. 

 

Replacement of batteries located in an OPERATOR ACCESS AREA. When replacing batteries, replace with 

the same number of the following battery: CyberPower / RB1290X2 for the GX1500U. 

CAUTION!    RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED 

BATTERIES ACCORDING TO LOCAL REGULATIONS. 

CAUTION!    Risk of Energy Hazard, 24 V, maximum 9 Ampere-hour battery. Before replacing batteries, 

remove conductive jewelry such as chains, wrist watches, and rings. High energy conducted through these 

materials could cause severe burns. 

CAUTION!    Do not dispose of batteries in a fire. The batteries may explode. 

CAUTION!    Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be 

toxic. 

CAUTION:    A battery can present a risk of electrical shock and high short circuit current. The following 

precautions should be observed when working on batteries: 

(1)

 

Remove watches rings, or other metal objects. 

(2)

 

Use tools with insulated handles. 

BATTERY REPLACEMENT PROCEDURE

 

1.

 

Turn off and unplug all connected equipment. 

2.

 

Turn the UPS off and unplug it from the AC power source. 

3.

 

Turn the UPS on its side. 

4.

 

Remove the front panel retaining screws located on the bottom of the UPS. 

5.

 

Slide the front panel completely off of the unit. 

6.

 

Remove the fixed stand from the upper battery. 

7.

 

Remove the batteries from the compartment. 

8.

 

Disconnect the battery wires from the batteries. 

9.

 

Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color 

connectors from both the upper and lower battery pack. Note: Only use new batteries for 

replacement and both batteries should be replaced at the same time to ensure maximum life span. 

10.

 

Put the batteries back into the compartment and reattached the fixed stand. 

11.

 

Slide back the battery compartment cover and tighten the retaining screws. 

12.

 

Recharge the UPS for 8-16 hours to fully charge the battery. 

 

REMINDER:    Batteries are considered HAZARDOUS WASTE and must be disposed of properly.    Most 

retailers that sell lead-acid batteries collect used batteries for recycling, as required by local regulations. 

 

Advanced Energy-Saving Design 

The GreenPower UPS™ has a high-efficiency charger, which makes it the most 

energy-efficient UPS in its class. The advanced high-frequency charging system 

significantly improves charging efficiency and conserves energy. As a result of this 

advanced design, the GreenPower UPS™ uses less energy compared to competitive 

models. The GreenPower UPS™ is manufactured in accordance with the Restriction on 

Hazardous Substances (RoHS) directive making it one of the most 

environmentally-friendly UPS on the market today. 

 

FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause undesired operation. 

Note:

 This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures: 

-

 

Reorient or relocate the receiving antenna. 

-

 

Increase the separation between the equipment and receiver. 

-

 

Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. 

-

 

Consult the dealer or an experienced radio/TV technician for help. 

Important

: Changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment. 

Canadian Compliance Statement CAN ICES-3 (B)/NMB-3(B) 

 

PRODUCT REGISTRATION 

IMPORTANT SAFETY INSTRUCTIONS 

INSTALLING YOUR UPS SYSTEM 

BASIC OPERATION 

BATTERY REPLACEMENT 

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY 

FCC COMPLIANCE STATEMENT 