background image

 
 
 
 
 
 
 

User’s Manual 

Step-Down Transformer

 

OL6KRT2UTFHWIO 

OL10KRT2UTFHWIO 

OL6KRT2UTFHWIOR 

OL10KRT2UTFHWIOR 

 

 

 

 

 

CyberPower Systems (USA), Inc. 

4241 12th Avenue East Suite 400 Shakopee, MN 55379 

Phone: 877-297-6937 

Fax: 952-403-0009 

www.CPSww.com

 

 

 

 

K01-0000362-01 

Summary of Contents for OL10KRT2UTFHWIO

Page 1: ...own Transformer OL6KRT2UTFHWIO OL10KRT2UTFHWIO OL6KRT2UTFHWIOR OL10KRT2UTFHWIOR CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403 0009 www CPSww com K01 0000362 01 ...

Page 2: ...he UPS and connected equipment from any outside utility line fluctuations or interference 2U Step Down and Isolation Transformer User s manual Registration card Rackmount left rail Rackmount right rail Tie plate 1 1 set 2U Rackmount ears Stands 2 1 set Input output terminal block cover 1 Flat head screws M5X8L 8 1 set Pan head screws M5X12L 12 1 set Plastic washers 8 1 set Screw hole dust covers 1...

Page 3: ...ches deep Select the proper holes in the rack for positioning the Step Down Transformer in the rack The 2U Step Down Transformer takes up position 1 through position 6 The 3U Step Down Transformer takes up position 1 through position 9 Step 3 Adjust rackmount rails to fit your rack Attach the rackmount rail to your rack with two M5X12L screws and two plastic washers at the front of the rack Locate...

Page 4: ...module Step 3 Attach dust covers Insert dust covers into the rackmount ear screw holes that are not being used SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidity controlled indoor area free of conductive contaminants Do not install this UPS where excessive moisture or heat is present Please see specifications for acceptable temperature and humidity range CA...

Page 5: ...RING Check wiring dimensions with the following table Step Down and Isolation Transformers with hardwire Wiring AWG Wiring mm 2 OL6KRT2UTFHWIO OL6KRT2UTFHWIOR 10 AWG 5 5 mm 2 OL10KRT2UTFHWIO OL10KRT2UTFHWIOR 6 AWG 14 0 mm 2 Step 1 Separate the top and bottom covers Loosen the four screws to separate the top and bottom covers Step 2 Fix the bottom cover on the terminal block Tighten the two screws ...

Page 6: ...figuration Insert the input output cables through the appropriate cable gland Hardwire the input output terminals as shown in the following terminal block identification and configuration table Step 4 Fix the top cover on the bottom cover Tighten the four screws to fix the top cover on the bottom cover ...

Page 7: ...t Voltage L1 L2 200Vac L1 N L2 100Vac 0 100Vac L1 L2 200Vac L1 L2 220Vac L1 N L2 110Vac 0 110Vac L1 L2 220Vac L1 L2 230Vac L1 N L2 115Vac 0 115Vac L1 L2 230Vac Input Voltage AC Output Connection Output Voltage L1T L2 208Vac L1 N L2 120Vac 0 120Vac L1 L2 240Vac L1 L2T 208Vac Input Voltage AC Output Connection Output Voltage L1 L2 240Vac L1 N L2 120Vac 0 120Vac L1 L2 240Vac L1 L2T 208Vac ...

Page 8: ...Copyright 2014 CyberPower Systems Inc HARDWIRING THE INPUT OUTPUT TERMINALS 7 POWER CABLE CONNECTION OL6000RT3UTF OL6000RT3UPDUTF OL8000RT3UTF OL10000RT3UTF OL8000RT3UPDUTF OL10000RT3UPDUTF ...

Page 9: ...o UPS outlet output terminal block 3 Battery Backup Surge Protected Outlets 120Vac Provides battery backup and surge protection They ensure power is provided to connected equipment over a period of time during a power failure 4 Output Circuit Breaker 120Vac Provides output overload and fault protection OL6KRT2UTFHWIO OL10KRT2UTFHWIO OL6KRT2UTFHWIOR OL10KRT2UTFHWIOR OL6KRT2UTFHWIOR OL10KRT2UTFHWIOR...

Page 10: ...Inc Model OL6KRT2UTFHWIOR OL6KRT2UTFHWIO OL10KRT2UTFHWIOR OL10KRT2UTFHWIO Configuration Maximum Output Power VA 6000VA 10000VA Maximum Output Power W 6000W 10000W Form Factor Rackmount Tower Input Nominal Input Voltage 200 208 220 230 240Vac Input Voltage Range 200 240Vac Input Current Rating 30A 50A Input Frequency 50 60Hz Output Nominal Output Voltage 100 110 115 120Vac or 200 208 220 230 240Vac...

Page 11: ...he Purchase Date and each item of Connected Equipment 2 Email us at tech cpsww com or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated purchase receipt or invoice How Do You Open A Connected Equipment Claim 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail m...

Page 12: ... 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T...

Page 13: ...l interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits This document is believed to be accurate but CyberPower reserves the right to change or correct the contents and does not assume any responsibility for omissions or errors Need Additional Help Fe...