background image

 

 
 
 
 

 

 

 

 

 

SE425G/SX500G/SX550G/SX625G 

CP425G/CP425HG/CP500HG/CP550HG/CP625HG 

User

’s Manual 

K01-0000218-01

 

 
 

 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. 

Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component. 

CAUTION!

    Not for use in a computer room as defined in the Standard for the Protection of  Electronic Computer/Data Processing Equipment, 

ANSI/NFPA 75.

 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit  over  current  protection in 

accordance with the National Electric Code, ANSI/NFPA 70. 

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

CyberPower  Systems  does  not  sell  products  for  life  support  or  medical 

applications.   

DO NOT

 use in any circumstance that would affect operation and safety of life support equipment, any medical applications or 

patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation 

from the aquarium can cause the unit to short out. 

 
 

 

 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS unit (b) 

User’s manual (c) USB device cable (except for SE425G, CP425G)

 

*PowerPanel®  Personal Edition software is available on our website. Please visit www.cpsww.com and go to the Software Section for 

free download.

 

 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.

  Ensure that the equipment plugged into the UPS does not e

xceed the UPS unit’s rated capacity. If the rated capacities of the unit are 

exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.     

2.

  There are many factors that can affect the amount of power that your electronic equipment will require.    For optimal system performance 

keep the load below 80% of the 

unit’s rated capacity. 

 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to   

ensure the battery

’s maximum charge capacity, it is recommended that you charge the battery   

for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is   

plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or   

turned off. 

2.  With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the 

battery power supplied outlets. Plug the other peripheral equipment (eg. printer, scanner, speakers, etc.) into the full-time surge protection 

outlets.   

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical 

device into the 

“Battery and Surge Protected Outlets”. The power demands of these devices will overload and possibly damage the 

unit. 

3.  To protect a fax, phone, or modem line, connect a telephone cable from the wall jack outlet to the IN jack of the   

UPS. Connect a telephone cable from one of the UPS OUT jacks to the modem port on the computer. The other   

UPS OUT jack can be used to protect a telephone or fax machine. 

4.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is   

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air   

conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips,   

and surge strips in conjunction with the UPS unit. 

5.  Press the power switch to turn the unit on. The Power On indicator light will illuminate green 

and the unit will “beep” twice. 

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

8.  To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every 

three months to ensure optimal battery life. 

9.  Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility. 

 

 

 

 

 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

① 

Battery and Surge Protected Outlets 

The unit has four battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a 

power failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large 

electrical device into the 

“Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly 

damage the unit.) 

② 

Full-Time Surge Protection Outlets 

The unit has four surge suppression outlets. 

③ 

Power Switch 

To turn the UPS on, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after a 

short beep. 

To turn the UPS off, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after two 

short beeps. 

Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The default setting is for the Alarm 

On. To turn the Alarm Off, quickly press the power button twice. You will hear two short beeps when the Alarm is turned Off. To turn the 

Alarm back ON, quickly press the power button twice. You will hear a single short beep when the Alarm is turned On. *When the Alarm is 

turned Off, there will be no audible notification when the UPS reaches a low battery state. 

④ 

Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. 

⑤ 

Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 

this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will 

not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

⑥ 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11) 

⑦ 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker provides overload and fault protection.   

⑧ 

USB Port to PC (except for SE425G, CP425G) 

The port allows connection and communication between the USB port on the computer and the UPS unit.    The UPS communicates its 

status to the PowerPanel

®

 Personal Edition software.

 

⑨ 

Outlets Designed for AC Adapters 

The UPS unit has four widely-spaced outlets, so AC power adapters can be plugged into the UPS without overlapping or blocking adjacent 

outlets. 

 

 

 

 

 

 
 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has been tripped due 
to an overload. 

Turn the UPS off and unplug at least one piece of 
equipment.    Wait 10 seconds, reset the circuit breaker by 
pressing the button, and then turn the UPS on.

 

The UPS does not perform 
expected runtime. 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is worn out. 

Contact CyberPower Systems about replacement batteries 
at 

tech@cpsww.com

   

The UPS will not turn on. 

The on/off switch is designed to 
prevent damage from rapidly turning 
it off and on. 

Turn the UPS off.    Wait 10 seconds and then turn the UPS 
on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 110/120V 50/60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries 
at 

tech@cpsww.com

 

Mechanical problem. 

Contact CyberPower Systems at 

tech@cpsww.com

 

The frequency is outside of the 
operating range of 47-63Hz.. 

Turn the UPS off. Make sure the frequency range is within 
47-63Hz. Or you can turn the UPS on in battery mode. 

PowerPanel

®

 Personal Edition is 

inactive (all icons are gray). 
*except for SE425G, CP425G 

The USB cable is not connected. 

Connect the USB cable to the UPS unit and an open USB 
port on the back of the computer. 

The USB / serial cable is connected 
to a bad USB port. 

Check for a different USB port and plug the cable in. 

The unit is not providing battery 
power. 

Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the 
unit. 

Additional troubleshooting information can be found at 

“Support” at 

www.CPSww.com

 

 

 

 

DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS

 

 

 

 

Power ON 

 

Wiring Fault 

 

Alarm 

CONDITION 

On 

Off 

Off 

Normal 

On* 

Off 

Beep twice   

every 30 seconds 

Utility Failure- 

The UPS is providing power to battery power-supplied 

outlets from its battery. 

On* 

Off 

Rapid Beeping 

every 1/2 second 

Utility Failure-

 The UPS is providing battery power.    Rapid beeping 

indicates the unit will run out of power shortly. 

Off 

Off 

Constant tone 

Battery  Overload  -

  Occurs  when  connected  equipment  exceeds  the 

listed  capacity  of  the  UPS.    Turn  the  UPS  off,  unplug  at  least  one 

piece  of  equipment  from  battery  outlets,  wait  10  seconds,  reset  the 

circuit breaker and turn the unit on. 

On/Off 

On 

None 

Electrical Wiring Fault - 

This 

indicates a wiring  problem with the 

AC  outlet

  such  as  bad  ground,  missing  ground,  or  reversed  wiring.   

Disconnect  all  electrical  equipment  from  the  outlet  and  have  an 

electrician check the outlet to insure proper wiring. 

On* 

Off 

8 beeps 

Utility Failure- The frequency is beyond 47-63Hz. The UPS will not 

turn on in Line Mode. 

* When it beeps, the power on LED will flash accordingly. 

 

 

 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

TROUBLESHOOTING 

IMPORTANT SAFETY WARNINGS 

 

 

 

Reviews: