background image

CMSI-4H4CV/CMSI-8H8CV

HDBaseT™ 4×4/8×8 HDMI Matrix over CAT5e/6/7

Operation Manual

Operation Manual

Summary of Contents for CMSI-4H4CV

Page 1: ...CMSI 4H4CV CMSI 8H8CV HDBaseT 4 4 8 8 HDMI Matrix over CAT5e 6 7 Operation Manual Operation Manual ...

Page 2: ... product Never push an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk o...

Page 3: ... 6 Operation Controls and Functions 3 6 1 Front Panel 3 6 2 Rear Panel 4 6 3 Side Panel 5 6 4 Remote Control 5 6 5 IR Cable Pin Assignment 6 6 6 RS 232 Pin Assignment 7 6 7 RS 232 and Telnet Commands 8 6 8 Telnet Control 9 6 9 Web GUI Control 11 7 Connection Diagram 13 8 Specifications 15 9 Acronyms 16 ...

Page 4: ...ital Plus and DTS HD Master Audio as well as 3D content that can be displayed when connecting a 3DTV and 3D source Power over Ethernet PoE support means that compatible receivers do not need their own power supplies allowing for greater flexibility in installations 2 APPLICATIONS HDMI Matrix System Video TV wall display and control Security surveillance and control Commercial advertising display an...

Page 5: ...on the output display EDID settings Supports PoE Power over Ethernet on compatible receivers only Supports HDMI input up to 15 meters at 8 bit resolution or 10 meters at 12 bit resolution Supports bi directional IR from input and output locations Supports RS 232 remote control on panel control and IP Control Telnet Web GUI 2U size design Supports external and internal EDID settings Supports LPCM 7...

Page 6: ... 4 IR IR Receiver window accepts the remote control signal of this device only with IR frequency of 38kHz 5 MENU Press this button to access the LCM menu system from here EDID settings can be managed and IP system settings are displayed 6 1 8 A H and OUT IN Press the OUT or IN button to select the output or input mode and then press the required number button to make the selection accordingly For ...

Page 7: ...ll blaster out all signal received from the IR IN at the receiver sides 4 ALL IR IN Connect to the IR extender for IR signal reception Ensure that remote being used is within the direct line of sight of the IR extender for it will send out the signal to all receiver s IR OUT 5 SERVICE Manufacturer use only 6 IR OUT A H Connect to the IR blasters for IR signal transmission Place the IR blaster in d...

Page 8: ... port 6 3 Side Panel 1 1 Fan Ventilator These are air ventilation areas DO NOT block these areas or cover it with any object Please allow adequate space around the unit for air circulation 6 4 Remote Control 1 POWER Press this button to switch on the device or set it to standby mode 2 IN Input ports selection 1 8 3 OUT Output ports selection A H Note This remote control can also be used from the r...

Page 9: ...6 6 6 5 IR Cable Pin Assignment 3 1 3 1 2 2 Power 5V IR Blaster Signal NC IR Signal Power 5V Grounding IR Extender IR Blaster ...

Page 10: ... Remote Control Console PIN Assignment PIN Assignment 1 NC 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate 19200 bps Data Bit 8 bit Parity None Stop Bit 1 bit Flow Control None Domestic HDMI Matrix System ...

Page 11: ...nfiguration was reset to factory defaults DHCP IPCONFIG Display the current IP config P0 Power Off P1 Power On I1 I8 Switch all the output to 1 8 ST Display the current matrix state and firmware version RS System Reset to H8 EM Setting EDID MODE 1 STD 2 TV Display all available commands QUIT Exit Telnet only Note 1 Any commands will not be executed unless followed by a carriage return Commands are ca...

Page 12: ... the PC Laptop are connected to the active networks To access the telnet control in Windows 7 click on the Start menu and type cmd in the Search field then press enter Under Windows XP go to the Start menu and click on Run type cmd with then press enter Under Mac OS X go to Go Applications Utilities Terminal See below for reference ...

Page 13: ... us into the device which we wish to control Type HELP to list the available commands Type IPCONFIG To show all IP configurations To reset the IP type RSTIP and to use a set static IP type SETIP For a full list of commands see Section 6 7 Note Any commands will not be executed unless followed by a carriage return Commands are case insensitive If the IP is changed then the IP Address required for Te...

Page 14: ...same active network as the Matrix open a web browser and type device s IP address on the web address entry bar The browser will display the device s status control and User setting pages Click on the Control tab to control power input output ports EDID and reset mode ...

Page 15: ...s you to reset the IP configuration The system will ask for a reboot of the device every time any of the settings are changed The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entry bar ...

Page 16: ... HDMI IN 2 HDMI IN 3 HDMI IN 4 HDMI IN 5 HDMI IN 6 HDMI IN 7 HDMI IN 1 2 3 4 5 6 7 RX ZONE B Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE C RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE D RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE E RX Power Extender Blaster IR 2 IR 1 RS232...

Page 17: ...F G H T CAT5e 6 OUT IR OUT IR IN CAT5e 6 OUT IR OUT IR IN CAT5e 6 OUT MAIN 24V POE 24V 6 HDMI IN 7 HDMI IN 8 HDMI IN 1 2 3 4 V GND GND GND V 6 8 7 X Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE E...

Page 18: ...R Blaster IR Frequency 30 50kHz Audio Sampling Rate Up to 192kHz ESD Protection Human body Model 8kV Air gap discharge 4kV Contact discharge Power Supply 24V 6 25A DC US EU standards CE FCC UL certified Dimensions 438mm W 255mm D 93mm H Weight 4238 g 4H4CV 4458 g 8H8CV Chassis Material Metal Silkscreen Color Black Operating Temperature 0 ºC 40 ºC 32 ºF 104 ºF Storage Temperature 20 ºC 60 ºC 4 ºF 14...

Page 19: ...D Video 4K2K 30Hz video formats 9 ACRONYMS ACRONYM COMPLETE TERM CLI Command Line Interface DTS Digital Theater System DVI Digital Visual Interface EDID Extended Display Identification Data GUI Graphical User Interface HDCP High bandwidth Digital Content Protection HDMI High Definition Multimedia Interface HDTV High Definition Television LCM Liquid Crystal Module USB Universal Serial Bus VGA Video Gr...

Page 20: ...Home page http www cypress com tw CYPRESS TECHNOLOGY CO LTD 20120518 MPM CMSI8H8CV ...

Reviews: