Please order bracket sets separately 

VCD 204-Z-TMS+ A

VCD 204-K-TMS+ B

With built-in power supply 

230 VAC
50 Hz

Summary of Contents for DYER VCD 204-K-TMS+ Set

Page 1: ...VCD 204 K TMS Set instructions Please order bracket sets separately VCD 204 Z TMS A VCD 204 K TMS B With built in power supply 230 VAC 50 Hz ...

Page 2: ...y that if one drive is cut off due to overload the other drivewillsimilarlybecutoff During the learning phase the activated stroke is transferredtothetandemdriveviatheTMS function TMS function Maintenance and cleaning Maintenance work is only allowed when the device is in a de energized condition Inspection and maintenance has to be carried out according to D H maintenance notes Only original D H ...

Page 3: ...ondary closing edge Secondary closing edge Type VCD 204 K TMS Set Power supply 230 VAC 10 15 50 60 Hz Power consumption 22 W 30 VA Nominal force 2x 200 N Nominal locking force approx 2x 2000 N Excluding bracket Service life 20 000 double strokes Duty cycle 30 With cycle time 10 minutes Housing Zinc diecasting powdercoated Ingress protection IP30 Temp range 0 60 C Emission sound pressure level LpA ...

Page 4: ...ly interrupted or the drives continues to the full stroke length please return to point 1 and start again 3 appr 100 m m learning mode appr 2 sec 2 Both drives must be electrically connected in order to set the stroke Only one drive needs to be switched to the stroke learning mode with the magnet V C D 2 0 4 K T M S B 24 VDC 230 VAC STOP Electrical devices accessories batteries and packa ging shou...

Page 5: ... SKS PinAssigment VCD 204 K VCD 204 K TMS B VCD 204 Z TMS A 230 VAC 24 VDC BN L BK L YE GN BU N s r WH 24 V YE TMS BN GN GY PK BN L BK L YE GN BU N BN L BK L YE GN BU N BN L BK L YE GN BU N max 50 V 0 5 A VCD 204 K TMS B VCD 204 Z TMS A 230 VAC 24 VDC WH 24 V YE TMS BN GN n c WH 24 V YE TMS BN GN n c WH 24 V YE TMS BN GN n c Optional signals mains supply Junction box ...

Page 6: ...E BN BK BU GN YE L N PE 230 VAC 50 Hz Connection WH BN YE 24 V TMS Patch cable BN brown BK black BU blue YE yellow GN green WH white PK pink GR grey L L N WH BN YE 230 VAC 24 VDC 24 V TMS VCD 204 K VCD 204 K TMS B VCD 204 Z TMS A ...

Page 7: ...mm 4 7 m m 240 mm 240 mm Dimensions Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 161 491 4840 E Mail enquiry dyerenvironmental co uk www dyerenvironmental co uk ...