Summary of Contents for DES-1018P

Page 1: ...3...

Page 2: ...mperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rate...

Page 3: ...g the Rubber Feet 7 Provide for Adequate Ventilation 7 Step 4 Power on the Switch 7 Power Failure 7 Step 5 Connecting the Switch 7 Connect to an End Node 8 Connect to a Hub or Switch 8 Connect to Netw...

Page 4: ...otential property damage or personal injury Copyright and Trademarks Information in this document is subjected to change without notice 2014 D Link Corporation All rights reserved Reproduction in any...

Page 5: ...n This simplicity is useful for SOHO and SMB users who have limited budgets but require PoE capability in a switch Product Outlook Front Panel Figure 1 DES 1018P MP Front Panel LEDs LED Color Status D...

Page 6: ...o a PoE device and is powering the device properly Red Solid light The PoE port has failed possibly due to 1 PoE total power budget shortage 2 Over current Exceeds the power current of powered device...

Page 7: ...wer supply and system a 12 to 6 AWG copper conductor is required for U S installation Commercially available 6 AWG wire is recommended The length of the cable depends on the proximity of the Switch to...

Page 8: ...e follow the steps below to set up the Switch 1 Install the DES 1018P MP in a cool and dry place Refer to the Technical Specifications for the acceptable operating temperature and humidity ranges 2 In...

Page 9: ...y while the system resets Power Failure As a precaution in the event of a power failure unplug the Switch When power is resumed plug the Switch back in Step 5 Connecting the Switch Users can attach IE...

Page 10: ...o the hardware characteristics MDI MDIX speed duplex of the device to which it is connected Switch connected to an end node Observe the guidelines for cable quality stated at the beginning of this sec...

Page 11: ...Connect to Network Backbone or Server Ports 17 to 18 may be used to uplink the Switch to a network backbone or network server When linking to a 1000BASE T device the port operates in full duplex mode...

Page 12: ...ard Band DES 1018P MP has reserved a 3 watt Guard Band to prevent the power supply from exceeding the PoE power budget When the current PoE output has reached 80 or 246 4 watts the Power Max LED will...

Page 13: ...ow control IEEE 802 3z IEEE 802 3az IEEE 802 3af Physical Environment Dimensions 280 mm x 210 mm x 44 mm Internal Power Supply AC input 100 240 VAC 50 60Hz Acoustic DES 1018P 38dB DES 1018MP 36 8 dB A...

Page 14: ......