background image

 

 

 

 

 

 

 

 

Summary of Contents for DGS-1224TP - Web Smart Switch

Page 1: ......

Page 2: ...anagement Utility 4 Supported Web Browsers 4 Connecting to the Switch 4 Login Web based Management Utility 5 Smart Wizard 5 Web based Management Utility 5 SmartConsole Utility 5 Product Introduction 7...

Page 3: ...ing 34 Configuration Power Saving 35 Power over Ethernet PoE PoE Port Settings Only for DGS 1224TP 35 Power over Ethernet PoE PoE System Settings Only for DGS 1224TP 36 QoS 802 1p DSCP Priority Settin...

Page 4: ...Table of Contents D Link Web Smart Switch User Manual iii QoS Quality of Service 3 Security 3 Management 3...

Page 5: ...ser you may have to append http in the web address For the latest information about the Web Smart Switches visit Resource Website D Link www dlink com Technical Support support dlink com Terms Usage I...

Page 6: ...lation and operation it is recommended that you Visually inspect the power cord to see that it is secured fully to the AC power connector Make sure that there is proper heat dissipation and adequate v...

Page 7: ...e rack or chassis Step 3 Plugging in the AC Power Cord Users may now connect the AC power cord into the rear of the switch and to an electrical outlet preferably one that is grounded and surge protect...

Page 8: ...Utility you don t need to change the IP address of your PC and it is easy to start the initial setting of multiple Smart Switches Please refer to the following detailed installation instructions for t...

Page 9: ...is will automatically load the web configuration in your web browser When the following login box appears enter the password then press OK to entering the Web based Management Utility The default pass...

Page 10: ...nt of your PC and use the SmartConsole Utility to discover the Smart Switches Option 2 Follow these steps to install the SmartConsole Utility manually 1 Insert the Utility CD into your CD Rom Drive 2...

Page 11: ...k Asymmetric VLAN is implemented in these switches for a more efficient use of shared resources such as server or gateway devices Network Security D Link s innovative Safeguard Engine function protect...

Page 12: ...anel Figure 10 DGS 1224T Front Panel Power LED The Power LED flashes when the Switch is connected to a power source CPU LED When the CPU LED is blinking then the switch is in the normal condition If t...

Page 13: ...hat one or multiple fans are working abnormally Mode Button To select the mode of port LED the Link Act and PoE LED under the mode button will solid green to indicate which mode is selected Port LED 1...

Page 14: ...Front Panel Power LED The Power LED flashes when the Switch is connected to a power source CPU LED When the CPU LED is blinking then the switch is in the normal condition If the CPU LED is off or stay...

Page 15: ...3 Product Introduction D Link Web Smart Switch User Manual 11 Rear Panel Figure 15 DGS 1248T Rear Panel Power The power port is where to connect the AC power cord...

Page 16: ...y SmartConsole Settings The SmartConsole Settings at the left has five icons Utility Settings Log Trap File and Help Utility Settings By clicking on this icon the Utility Settings window will pop up R...

Page 17: ...nsole Log Trap By clicking on this icon the Trap window will pop up Click View Trap to show the events of the SmartConsole Utility and the device Date Time indicates when the trap was received IP indi...

Page 18: ...List as default for the next time the SmartConsole Utility is used Monitor Save As To record the setting of the Device List in an appointed filename and file path Monitor Load To manually load a Devic...

Page 19: ...device buttons for the Device List Device Settings Select a switch from the Device List then clicking on this icon the Device Settings window will pop up Here you can configure the Product Name IP Add...

Page 20: ...se then input the correct password of device and click Upgrade and wait the upgrade successfully message pop up to complete the firmware upgrade Figure 24 Firmware Upgrade CAUTION Do not disconnect th...

Page 21: ...may also get into the Web based Management Utility by double clicking the device in the device list Add Delete and Discover the device By pressing the Discovery button all the Web Smart devices locate...

Page 22: ...to Please check if the power or the cable of this device is disconnected IP Address Shows the current IP addresses of devices MAC Address Shows the device MAC Address Protocol version Shows the versi...

Page 23: ...gement Utility When The Smart Wizard will guide you to quick configure some functions If you don t plan to change anything click Exit to exit the Wizard and enter the Web Interface Password Settings P...

Page 24: ...P function description please see Setup Menu System SNMP Settings The default SNMP Setting is Disabled Click Enabled the Apply to configure Community Settings Public Read only privilege allows authori...

Page 25: ...default setting of System IP address is DHCP Figure 31 Configure System IP address in Smart Wizard NOTE Changing the system IP address will disconnect you from your internet connection please enter th...

Page 26: ...creen The main configuration screen will show the current status of your Switch by clicking the model name on top of the function tree At the upper right of the screen you can see your username and cu...

Page 27: ...p settings file you want to restore Note To restore the configuration the switch will restart and all current configurations will be lost Firmware Backup and Upload Allow for the firmware to be saved...

Page 28: ...DHCP mode the Switch will first look for a DHCP server to provide it with an IP address network mask and default gateway before using the default or previously entered settings By default the IP sett...

Page 29: ...estination IP address of the managing station that will receive trap information Figure 41 System Trap Setting You can choose which event to send to the managing station System Event Monitors the syst...

Page 30: ...rity settings in Qos 802 1p Default Priority NOTE When the Combo Fiber port and the Copper ports are both connected the Fiber port will take precedence over the Copper ports meaning the Fiber port wil...

Page 31: ...ilege allows authorized management stations to retrieve and modify MIB objects Trap Setting Traps are messages that alert network personnel of events that occur on the Switch Such events can be as ser...

Page 32: ...s though they were in the same area VLANs can be easily organized to reflect department groups such as R D Marketing usage groups such as e mail or multicast groups multimedia applications such as vid...

Page 33: ...in different VLANs to communicate with the servers firewalls or other shared resources in the shared VLAN This configuration is accomplished in three steps Enabling Asymmetric VLAN function Creating s...

Page 34: ...hared VLAN ports and the set of ports to be separated from the other subset VLANs For example port 5 VLAN 3 and 4 are then configured to include shared ports and the set of ports to be separated from...

Page 35: ...d larger bandwidth Up to six Trunk groups may be created each supporting up to 8 ports Add a Trunking Name and select the ports to be trunked together and click Apply to activate the selected Trunking...

Page 36: ...ue results in reduced time to detect the loss of the last member of a group Default is 1 second Host Timeout System assigned This is the interval after which a learnt host port entry will be purged Fo...

Page 37: ...signed to prevent network loops that could cause a broadcast storm When physical links forming a loop provide redundancy only a single path will be forwarding frames If the link fails STP activates a...

Page 38: ...maximum amount of time that the root device will wait before changing states The default is 15 seconds Root Bridge Displays the MAC address of the Root Bridge Root port Displays the root port Root Pat...

Page 39: ...r Saving Power over Ethernet PoE PoE Port Settings Only for DGS 1224TP DGS 1224TP supports Power over Ethernet PoE as defined by the IEEE 802 3af specification Ports 1 24 can supply 50VDC power to PDs...

Page 40: ...ower feeding is temporary shut down because of PD suddenly require more power which over the maximum power limitation defined on corresponding port Please disconnect the PD and check if there is damag...

Page 41: ...rtant functions that require a larger bandwidth or that might have a higher priority such as VoIP voice over Internet Protocol web browsing applications file server applications or video conferencing...

Page 42: ...ty level has reached its egress weight the system will process the packets in the next level even if there are remaining packets D Link Smart Switch system s weight of priority levels are 8 Highest 4...

Page 43: ...ine D Link s Safeguard Engine is a robust and innovative technology that automatically throttles the impact of packet flooding into the switch s CPU This function helps protect the Web Smart Switch fr...

Page 44: ...curity select enabled and set the 802 1X Global Settings for the Radius Server and applicable authentication information Authentication Port sets primary port for security monitoring Default is 1812 K...

Page 45: ...earning for any of the uplink ports press On to enable this feature and select the port s for auto learning to be disabled The Static Mac Address Setting table displays the static Mac addresses connec...

Page 46: ...uccessfully TxError Number of transmitted packets resulting in error RxError Number of received packets resulting in error To view the statistics of individual ports click one of the linked Port numbe...

Page 47: ...cured during cable diagnostics Please select the same port and test again Cable Fault Distance meters Indicates the distance of the cable fault from the Switch port if the cable is less than 2 meters...

Page 48: ...ction which will create a flexible foundation for the next generation of network technology products Fast Ethernet Technology The growing importance of LANs and the increasing complexity of desktop co...

Page 49: ...rting category 5 5e up to 100 Meters PoE will provide power to PoE compatible devices such as IP telephones wireless LAN access points and IP security cameras PoE is already widely adopted in the mark...

Page 50: ...211 100BASE FX WDM Transceivers Supported DEM 330T TX 1550 RX 1310nm DEM 330R TX 1310 RX 1550nm DEM 331T TX 1550 RX 1310nm DEM 331R TX 1310 RX 1550nm Physical Environment AC input 100 240 VAC 50 60Hz...

Page 51: ...chnical Specifications D Link Web Smart Switch User Manual i ii i Port access control Web based configuration backup restoration Web based firmware backup upload Firmware upgrade using SmartConsole Ut...

Page 52: ......

Reviews: