background image

 

 

 

   

   DI-704 

User Manual

 

 

 

 

 

RECYCLABLE 

Printed in Taiwan 

 

Summary of Contents for DI-704

Page 1: ...DI 704 User Manual RECYCLABLE Printed in Taiwan ...

Page 2: ...nd materials from the date of original retail purchase of the Hardware for the period set forth below applicable to the product type Warranty Period if the Hardware is used and serviced in accordance with applicable documentation Product Type Warranty Period Product excluding power supplies and fans if purchased and delivered in the fifty 50 United States or the District of Columbia USA As long as...

Page 3: ...ith software that substantially conforms to D Link s functional specifications for the Software Except as otherwise agreed by D Link in writing the replacement Software is provided only to the original licensee and is subject to the terms and conditions of the license granted by D Link for the Software The Warranty Period shall extend for an additional ninety 90 days after any replacement Software...

Page 4: ...NY TERRITORY WHERE A PRODUCT IS SOLD THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO NINETY 90 DAYS EXCEPT AS EXPRESSLY COVERED UNDER THE LIMITED WARRANTY PROVIDED HEREIN THE ENTIRE RISK AS TO THE QUALITY SELECTION AND PERFORMANCE OF THE PRODUCT IS WITH THE PURCHASER OF THE PRODUCT Limitation of Liability TO THE MAXIMUM EXTENT PERMITTED BYLAW D LINK IS NOT LIABLE UNDER ANY CONTRACT NEGLI...

Page 5: ...tände oder Flüssigkeiten in das Gerät gelangen Dies könnte einen Brand bzw Elektrischen Schlag auslösen 14 Öffnen Sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden 15 Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen a Netzkabel oder Ne...

Page 6: ...ences radio auquel cas l utilisateur devrait prendre les mesures adéquates Attenzione Il presente prodotto appartiene alla classe B Se utilizzato in ambiente domestico il prodotto può causare interferenze radio nel cui caso è possibile che l utente debba assumere provvedimenti adeguati FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursu...

Page 7: ...VII Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help VCCI Warning ...

Page 8: ...Network Settings 6 Chapter 4 Configuring The DI 704 8 4 1 Start up and Log in 8 4 2 Status 9 4 3 Tools 10 4 4 Setup 11 4 5 DHCP Server 13 4 6 Virtual Server 14 4 7 Special AP 15 4 8 Access Control 16 4 9 Misc Items 17 Appendix A Console Mode 18 Appendix B TCP IP Configuration for Windows 95 98 19 B 1 Install TCP IP Protocol into Your PC 19 B 2 Set TCP IP Protocol for Working with the DI 704 20 App...

Page 9: ...he DI 704 1 1 Functions and Features Broadband modem and IP sharing Connects multiple computers to a broadband cable or DSL modem or an Ethernet router to surf the Internet Auto sensing Ethernet Switch Equipped with a 4 port 10 100Mb auto sensing Ethernet switch VPN supported Supports multiple PPTP sessions and allows setup of a VPN server and VPN clients Firewall All unwanted packets from outside...

Page 10: ...requiring multiple connections like Internet gaming video conferencing Internet telephony and so on then the DI 704 can sense the application type and open a multi port tunnel for it DMZ Host supported DMZ Host fully exposes a networked computer to the Internet Use this feature when the special application sensing tunnel feature does not allow an application to function properly 1 2 Packing List O...

Page 11: ...ding port is sending or receiving data 10 100 10 100 status indicators Green The LED flickers when the corresponding port is transmitting or receiving data in 10 or 100Mbps Port 1 4 LAN port socket RJ 45 These are where you will connect to device on your local area network for example HUB and switch RESET To reset system settings to factory defaults please follow the steps 1 Power off the device 2...

Page 12: ...ay cause damage to the DI 704 2 2 Installation Requirements The DI 704 can be positioned at any convenient place in your office or house No special wiring or cooling requirements is needed However you should comply with the following guidelines to install Place the DI 704 on a flat horizontal surface Keep the DI 704 away from excessive heat Do not place the DI 704 in a dusty or wet environment The...

Page 13: ...backbone Figure 2 4 illustrates the WAN connection Figure 2 4 Setup of WAN connections for DI 704 3 Power on Connect the power cord to power inlet and turn the power switch on The DI 704 will automatically enter the self test phase When in the self test phase the indicators M1 and M2 will be lighted ON for about 5 seconds and then M1 and M2 will flash three times to indicate that the self test ope...

Page 14: ...r installing the TCP IP communication protocol you can use the ping command to check if your computer has successfully connected to the DI 704 The following example shows the ping procedure for Windows 95 platforms First execute the ping command ping 192 168 0 1 If the following messages appear Pinging 192 168 0 1 with 32 bytes of data Reply from 192 168 0 1 bytes 32 time 2ms TTL 64 A communicatio...

Page 15: ...N LED of the DI 704 and the link LED of network card on your computer must be lighted 2 Is the TCP IP environment of your computers properly configured Tip If the IP address of the DI 704 is 192 168 0 1 the IP address of your computer must be 192 168 0 X and default gateway must be 192 168 0 1 ...

Page 16: ...he IP address of the DI 704 into the exceptions box Then type the DI 704 s IP address for example default setting http 192 168 0 1 in the Location for Netscape or Address for IE field and press ENTER After the connection is established you will see the web user interface of the DI 704 To log in as an administrator enter the system password the factory setting is admin in the System Password field ...

Page 17: ...e DI 704 s working status A WAN Port Status If the WAN port is assigned a dynamic IP there may appear a Renew or Release button on the Sidenote column You can click this button to renew or release IP manually B Modem Status C Firmware version and WAN s MAC Address ...

Page 18: ...sword view the log and clone the MAC address You can also reboot the DI 704 by clicking the Reboot button Note We strongly recommend that the system password be changed for security reasons If you forget the system password please refer to Appendix A to reset a new one ...

Page 19: ...ess is 192 168 0 1 You can change it to your need 2 WAN Type WAN connection type of your ISP You can click the Change button to choose a correct one from the following four options A Static IP Address ISP assigns you a static IP address B Dynamic IP Address Obtain an IP address from ISP automatically C PPP over Ethernet Some ISPs require the use of PPPoE to connect to their services D Dial up Netw...

Page 20: ...the service name if your ISP requires it 3 Maximum Idle Time the maximum time the connection is idle before you are disconnected from your ISP and your PPPoE session is terminated 4 4 4 Dial up Network 1 Dial up Telephone Account and Password assigned by your ISP If you don t want to change the password keep it empty 2 Primary and Secondary DNS automatically assigned if they are configured as 0 0 ...

Page 21: ... configure your computers as automatic IP allocation mode then when your computer is powered on it will automatically load the proper TCP IP settings from the DI 704 The settings of DHCP server include the following items 1 DHCP Server Choose Disable or Enable 2 Range of IP Address Pool Whenever there is a request the DHCP server will automatically allocate an unused IP address from the IP address...

Page 22: ...irtual Server Mapping A virtual server is defined as a Service Port and all requests to this port will be redirected to the computer specified by the Server IP For example if you have an FTP server port 21 at 192 168 0 1 a Web server port 80 at 192 168 0 2 and a VPN server at 192 168 0 6 then you need to specify the following virtual server mapping table Service Port Server IP Enable 21 192 168 0 ...

Page 23: ...insufficient to allow an application to function correctly try DMZ host in the Misc Items options 1 Trigger the outbound port number the application issued first 2 Incoming Ports when the trigger packet is detected the inbound packets to the specified port numbers are allowed to pass the firewall The DI 704 provides some predefined settings in the gray pad on the bottom of the web page Choose the ...

Page 24: ... all members of the Default Group Second you have to assign the access rights of each group Access rights can allow or block users to access specified TCP and UDP ports For example Group Members Access Right Comments Default Allow No access right allow nothing Group 1 100 199 Allow 25 53 80 110 Can browse 80 receive 110 and send 25 email only Group 2 50 99 Block 21 119 Cannot read net news 119 and...

Page 25: ...Administrator Host In general only Intranet users can browse the built in web pages to perform administrative tasks This feature enables you to perform administrative tasks from a remote host If this feature is enabled only the specified IP address can perform remote administration If the specified IP address is 0 0 0 0 any host can connect to the DI 704 to perform administrative tasks When this f...

Page 26: ...l program such as the Hyper Terminal of MS Windows 95 The connection parameters should be set to 19200 8 N 1 And reboot the DI 704 When the M1 indicator starts flashing regularly you can press the Enter key of the keyboard several times there should be some messages and console prompt appears in the terminal In the console mode you may reset the IP address and the system password of the DI 704 Ple...

Page 27: ...please refer to your network card manual Moreover the Section B 2 tells you how to set TCP IP values for working with the DI 704 correctly B 1 Install TCP IP Protocol into Your PC 1 Click Start button and choose Settings then click Control Panel 2 Double click Network icon and select Configuration tab in the Network window 3 Click Add button to add network component into your PC 4 Double click Pro...

Page 28: ...tton to return to Network window 6 The TCP IP protocol shall be listed in the Network window Click OK to complete the install procedure and restart your PC to enable the TCP IP protocol B 2 Set TCP IP Protocol for Working with the DI 704 1 Click Start button and choose Settings then click Control Panel ...

Page 29: ...t the TCP IP line that has been associated to your network card in the Configuration tab of the Network window 3 Click Properties button to set the TCP IP protocol for the DI 704 4 Now you have two setting methods A Get IP via DHCP server ...

Page 30: ...22 a Select Obtain an IP address automatically in the IP Address tab ...

Page 31: ...23 b Don t input any value in the Gateway tab ...

Page 32: ...24 c Choose Disable DNS in the DNS Configuration tab ...

Page 33: ...ally a Select Specify an IP address in the IP Address tab The default IP address of the DI 704 is 192 168 0 1 So please use 192 168 0 xxx xxx is between 1 and 253 for IP Address field and 255 255 255 0 for Subnet Mask field ...

Page 34: ...26 b In the Gateway tab add the IP address of the DI 704 default IP is 192 168 0 1 in the New gateway field and click Add button ...

Page 35: ...27 c In the DNS Configuration tab add the DNS values which are provided by the ISP into DNS Server Search Order field and click Add button ...

Page 36: ...BASE TX Fast Ethernet IEEE 802 3x Flow Control ANSI IEEE 802 3 NWay auto negotiation Management Web Based Ports 4 x NWay 10BASE T 100BASE TX Fast Ethernet LAN 1 x 10BASE T WAN 1 x RS 232 DB 9 LED s Power WAN Activity LAN Activity M1 M2 Power DC 5V 2A Operating Temperature 5 C 55 C Humidity 10 90 ...

Page 37: ...0 4000 toll free REPAIR LINE 00800 7250 8000 E MAIL info dlink de INDIA D LINK INDIA Plot No 5 Kurla Bandra Complex Road Off Cst Road Santacruz E Bombay 400 098 India TEL 91 22 652 6696 FAX 91 22 652 8914 URL www dlink india com E MAIL service dlink india com ITALY D LINK ITALIA Via Nino Bonnet No 6 b 20154 Milano Italy TEL 39 02 2900 0676 FAX 39 02 2900 1723 URL www dlink it E MAIL info dlink it ...