background image

INSTRUCTION BOOK FOR

 

Tensioned Contour

®

 Electrol

®

Summary of Contents for TENSIONED CONTOUR ELECTROL

Page 1: ...INSTRUCTION BOOK FOR Tensioned Contour Electrol ...

Page 2: ...nce with the wiring rules 4 Rated for indoor use only 5 Use copper rated conductors rated 167 F 75 C or higher 6 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid hazard 7 Supplied drive is only intended for use in Da Lite screen models Advantage Contour and Cosmopolitan 8 Position the cord so that it will not b...

Page 3: ...ket 5 Tighten the two stop screws against the wall mount bracket using a 2 Phillips screwdriver Figure 1 Ceiling Flush Mount 1 The ceiling hook brackets are attached to the top side of the housing They must be removed prior to ceiling flush mount NOTE Do not remove the wall mount bracket even if you are not using it for mounting This provides structural stability to the case 2 Using a 2 Phillips s...

Page 4: ...gure 4 Ceiling Hook Mount 1 The ceiling hook mount brackets are tied together and attached to the ceiling flush mount bracket at one end of the case Remove the ceiling hook mount brackets 2 Remove the ceiling flush mount brackets using a 2 Phillips screwdriver See Figure 3 Retain four 1 4 x 5 8 screws NOTE Do not remove the wall mount bracket even if you are not using it for mounting This provides...

Page 5: ...20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection t...

Page 6: ...k Orange Purple Brown 220V Wiring Diagram with Operation Limit Adjustment Wall Switch 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party contr...

Page 7: ...switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Hot Brown Common Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Down o...

Page 8: ... from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI NOTE When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Theref...

Page 9: ...ch will turn off the motor will return to run mode and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment NOTE All screens except Parallax standard with 12 black drop at the top Screens with Parallax surface standard with 2 of black drop at the top 4 To adjust the up limit switch press and hold the up tactile button until the LED on...

Page 10: ...ure across the common up and down wires will be a stop command Operation of Screen Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 Press UP button on screen switch and screen will retract upward into case Up Button Stop Button Down Button U...

Page 11: ...Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment See installation instructions Incorrect stopping position in upward direction Lost roller wrap See instructions below Up limit switch...

Page 12: ...RRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the five 5 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICA...

Reviews: