background image

Installation Instructions

Distinctive

 Electric Range

Part No. 105906 Rev. B

Models: DR30ES, DR30EIS, DR30EFS and DR30EIFS

Summary of Contents for Distinctive DR30E

Page 1: ...Installation Instructions Distinctive Electric Range Part No 105906 Rev B Models DR30ES DR30EIS DR30EFS and DR30EIFS...

Page 2: ...16 Re installing the Oven Door 16 Verifying Proper Operation 17 Customer Service Information If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Daco...

Page 3: ...ages in the oven bottom or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause a fire hazard Aluminum foil linings may also trap heat caus...

Page 4: ...owner is responsible to make sure this appliance is properly installed This appliance must not be used in combination with surface countertop ventilation systems The use of an overhead hood or Dacor r...

Page 5: ...talled by a licensed electrician The appliance may be connected one of the following ways Using conduit A 4 wire conduit connected to a 4 wire junction box or A 3 wire conduit where local code permits...

Page 6: ...lat stainless trim piece in place of a backguard A backguard may be purchased as an optional accessory Add an additional 1 16 inch to depth dimensions above when installing a backguard on models DR30E...

Page 7: ...is to be provided directly above the range the risk of personal injury may be reduced by installing a range hood The range may be installed flush to the rear wall Dacor recommends installing a non com...

Page 8: ...ountertop front Top View Slide In Self Rimming Installation 3 Side Panels Installed Top View Slide In Self Rimming Installation 3 Side Panels Removed Self Rimming Installation Cutout Options Models DR...

Page 9: ...les above counter both sides 22 3 4 57 8 cm 2 5 8 6 7 cm 24 3 8 61 9 cm max Countertop front Self Rimming Installation with Raised Vent Cutout Options Models DR30EIS and DR30EIFS Only Countertop heigh...

Page 10: ...quired The minimum full thread depth portion of screw threaded into wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See the table below to select the correct screw size Sub Floor Type Floor...

Page 11: ...thod may not be used and the floor mounting method must be suitable or the wall must be modified so that the base plate is above the notches 4 To install the bracket place it against the wall in the m...

Page 12: ...ance Dacor is not responsible for damages resulting from improper installation This range must be connected to a grounded metallic permanent wiring system Alternatively a grounding conductor should be...

Page 13: ...in relief inside the box Tighten into place 6 Connect the white wire to the neutral terminal in the box 7 Connect the black wire to the L1 power supply terminal 8 Connect the red wire to the L2 power...

Page 14: ...appliance to the junction box 2 Connect the white wire from the appliance to the neutral white supply wire in the junction box 3 Connect the black wire from the appliance to the black L1 power supply...

Page 15: ...Conduit Junction Box Connection with External Ground Separate No 10 minimum copper grounding wire Wire nut 4 places Conduit to appliance Conduit to appliance Wire nut 3 places Junction box Junction b...

Page 16: ...Do not connect the green appliance wire to the neutral white supply wire unless local building codes permit 1 Remove the range electrical access cover from the back of the range 2 If using a 4 wire c...

Page 17: ...umper link Link removed Ground screw L2 terminal L2 terminal L1 wire L1 wire White wire White wire Green wire L2 wire L2 wire Strain relief Strain relief 3 Wire Appliance Cord Connection Where Local C...

Page 18: ...loor to the countertop and adjust the leveling legs as required to position the top frame at the desired height based on the cabinet and countertop installation 2 Carefully slide the range into positi...

Page 19: ...repair the appliance yourself If you need service be sure to have the model and serial numbers available when you call See the inside cover for location Dacor is not responsible for the cost of corre...

Page 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: