PLANNING

GUIDE

DRT304S, DRT366S

Distinctive

®

 

30” and 36” Wide,

Slide-in Gas Rangetops

Document # PG04-003

Revised 10/17/14   Page 1/4

A

ELECTRIC CIRCUIT REQUIREMENTS

Circuit Required

Total Connected Load

120 Vac 60Hz, 15 Amp. (3 wire)

1.0 Amp @ 120 Vac, 60 Hz.

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type

Manifold Pressure

Minimum Gas Supply 

Pressure

Natural Gas

5” Water Column

6” Water Column

Propane (LP)

10” Water Column

11” Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

Installation of a non-combustible material* (up to the hood) or a backsplash 

is always recommended, and mandatory if the distance to the back 

wall from the rangetop is less than 2 1/2” (Figure 2). When installing a 

backguard, use only Dacor model number  AEB3609.

SIDE VIEW WITHOUT BACKGUARD

SIDE VIEW WITHOUT BACKGUARD

SIDE VIEW

Product Dimensions

Electrical and Gas Supply Requirements

Cabinet and Countertop Layout

RANGETOP WIDTH (A)

DRT304S

29 7/8” (75.9 cm)

DRT366S

35 7/8” (91.1 cm)

Product tolerances: 

±1/16” (±1.6 mm) 

unless otherwise noted

 WARNING

•  Observe all governing codes and ordinances during planning 

and installation. Contact your local building department for 

further information. 

•  This appliance must be installed in accordance with the 

accompanying installation instructions.

4” (10.2 cm)

5/8” (1.6 cm)

7 3/4”

 (19.7 cm)

Trim:

1/2”

 (1.3 cm)

thick

25 7/8” (65.7 cm)

1 5/8” (4.1 cm) cooking surface

height (grate level) above

countertop

3/4” gas inlet, connects to regulator from

bottom or rear of unit, end is recessed

2” (5.1 cm) from chassis bottom

28 1/8” (71.4 cm)

Power cord

32” (81.3 cm) long

Combustible

rear wall

Backguard mandatory if

gap from back of cooktop

to combustible wall is less

than 2 1/2”

Combustible

rear wall

2 1/2” (6.4 cm) min. to

combustible rear wall