PLANNING
GUIDE
DRT304S, DRT366S
Distinctive
®
30” and 36” Wide,
Slide-in Gas Rangetops
Document # PG04-003
Revised 10/17/14 Page 1/4
A
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
1.0 Amp @ 120 Vac, 60 Hz.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
Installation of a non-combustible material* (up to the hood) or a backsplash
is always recommended, and mandatory if the distance to the back
wall from the rangetop is less than 2 1/2” (Figure 2). When installing a
backguard, use only Dacor model number AEB3609.
SIDE VIEW WITHOUT BACKGUARD
SIDE VIEW WITHOUT BACKGUARD
SIDE VIEW
Product Dimensions
Electrical and Gas Supply Requirements
Cabinet and Countertop Layout
RANGETOP WIDTH (A)
DRT304S
29 7/8” (75.9 cm)
DRT366S
35 7/8” (91.1 cm)
Product tolerances:
±1/16” (±1.6 mm)
unless otherwise noted
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
4” (10.2 cm)
5/8” (1.6 cm)
7 3/4”
(19.7 cm)
Trim:
1/2”
(1.3 cm)
thick
25 7/8” (65.7 cm)
1 5/8” (4.1 cm) cooking surface
height (grate level) above
countertop
3/4” gas inlet, connects to regulator from
bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
28 1/8” (71.4 cm)
Power cord
32” (81.3 cm) long
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (6.4 cm) min. to
combustible rear wall