background image

Summary of Contents for EPICURE EH30

Page 1: ...EH30 EH36 EH42 EH48 EH54 MH30 MH36 and MH48 Instructions APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI UL 507 STANDARD FOR ELECTRIC FANS AND...

Page 2: ...customer Customer Keep these installation instructions for future reference and the local electrical inspector s use If You Need Help If you have questions or problems with installation contact your D...

Page 3: ...acent cabinets or areas WARNING If the information this manual is not followed exactly a fire or explosi0n may result causing property damagei personal injury or death WARNING to preven t power from b...

Page 4: ...hood switch power off at the fuse box circuit breaker and lock the electri cal panel door to prevent power from being switched on accidentally When the electrical panel cannot be locked securely faste...

Page 5: ...ecific Model Number EH48 MH48 EH42 EH30 MH30 EH54 EH36 MH36 Lights 3 2 2 Filters 4 3 2 Exhaust 2 1 1 Outputs Fan Rating 1200 CFM 600 CFM 600 CFM Weight Specifications Model EH3012 MH3012 EH3018 MH3018...

Page 6: ...e exhaust models Standard 8 duct connection M _ I I I I I S S _ 9 7 8 _ 25 1 cm 19 50 2 cm I _ I II l I II I Front of hood 6 1 8 15 6 cm f Top Dimensions 3 7 6 cm 4 10 2 cm 1_9 cm i_1 Electrical acces...

Page 7: ...cm 25 1 2 64 8 cm 26 7 8 68 3 cm 25 1 2 64 8 cm 12 3 8 31 4 cm 18 45 7 cm See diagram on facing page 4 1 2 11 4 cm 6 1 8 15 6 cm 32 81 3 cm 4 _ 34 9 cm Dimensions of Optional AHT10 Transition For dua...

Page 8: ...minimum dimensions are met or exceeded Dimensions shown provide minimum clearances unless otherwise noted All contact surfaces between the hood and any cabi nets or walls must be solid and at right an...

Page 9: ...duct outlet may also be required Make sure duct work does not interfere with floor joists or wall studs On dual exhaust models the two 8 exhausts may be merged into one 10 duct using Dacor transition...

Page 10: ...ting block between the studs behind all hood mounting locations You may attach screws directly to the studs and cabinets if they line up with the mounting holes in the back and top of the hood If moun...

Page 11: ...ce The owner is responsible to make sure the hood is properly installed Start by removing the filters from the bottom of the hood Put them in a safe location so that they will not be damaged If the ho...

Page 12: ...d back so that it lays on its back with the front pointing up Remove the filters from the under side of the hood Locate the wiring harness Cut the cable tie that takes up the slack in the cable It is...

Page 13: ...ring harness to the brace inside the hood on the right side using two 2 supplied cable ties 1 16 Use a cable tie to take up any remaining slack that may 2 exist in the wiring harness Stow the harness...

Page 14: ...rness cable ties Disconnect both wiring harness connectors from the blower motors While supporting each blower from below remove the four 4 nuts that hold the blower and mounting plates in place Remov...

Page 15: ...4 screws and the cover plate that covers the hole on the back of the hood Duct collar Cover plate IMPORTANT For proper operation route and secure the harness exactly as shown Cable tie if necessary 17...

Page 16: ...Stow the harness behind the plate on the right side Securing any slack will reduce additional noise due to vibration Cable clamps Wiring harness Cable ties 10 Insert the opening on the blower motor i...

Page 17: ...om the hood 10 Insert the opening of each blower motor into the holes inside the back of the hood The connector on the motors must be toward the bottom of the hood Attach them with four 4 nuts each 4...

Page 18: ...te a 3 4 flange around the base IMPORTANT On 12 high hoods modified to exhaust out the rear leave one of the long edges unbent Q Q 9 IMPORTANT For proper operation route and secure the harness exactly...

Page 19: ...ood center line drawn on the wall before making the duct cut out The distance from the center line depends on the model See the chart below TEMPORARY BRACKET CENTER LINE DISTANCE Models F EH3012 EH301...

Page 20: ...the hood working toward the outside vent Observe the specifications on page 7 Fasten all joints with sheet metal screws and seal with duct tape or certified silver tape 6 Lift the hood into its final...

Page 21: ...an Make sure all wire used is capable of handling the total connected load See page 3 1 Turn off power to the hood electrical circuit at the circuit 3 breaker or fuse box Feed the wiring through the w...

Page 22: ...ction box UL CSA approved NEMA strain relief To range hood Grounding the Hood Wiring Using an External Cold Water Pipe No 4 copper wire Meter Clamps Bare metal Insulated Pipe Jumper if necessary Light...

Page 23: ...337 3226 Do not attempt to repair the appliance yourself If you need service be sure to have the model and serial numbers available when you call See the inside cover for location Do not attempt to r...

Page 24: ...20V EACH _7 _ 7 W Y B_R O LL W W J J J 1098765432 11P2 K3 K2 K1 HOOD POWER AND CONTROL BOARD HOOD KEYPAD MEMBRANE MICROPROCESSOR PROGRAMMING HEADER 2 4681o 1357 9 P3 CHASSIS GROUND 11 10987654321 IP2...

Page 25: ...OD LIGHT 75W 120V HOOD LIGHT 75W 120V I _OBB 1wlw 11098765432 lIP2 K3 K2 K1 DDD HOOD POWER AND CONTROL BOARD Ill 10987654321 W W W MICROPROCESSOR PROGRAMMING HEADER 246810 1357 9 P3 B B GI B G B CONNE...

Page 26: ...24 c_acar...

Page 27: ...Family Owned American Made Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com The Life of the Kitchen...

Reviews: