background image

Operation manual

Daikin Altherma – Low temperature split

English

Operation manual

Daikin Altherma – Low temperature split

EHVZ04S18DA6V(G)

EHVZ08S18DA6V(G)
EHVZ08S23DA6V(G)

EHVZ08S18DA9W(G)
EHVZ08S23DA9W(G)

Summary of Contents for Altherma EHVZ04S18DA6V

Page 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G...

Page 2: ...the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for futu...

Page 3: ...he screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Dia...

Page 4: ...ription Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water tempe...

Page 5: ...anges and proceed 3 3 Space heating control 3 3 1 Setting the space operation mode About space operation modes This unit is a heating only model The system can heat up a space but NOT cool down a spac...

Page 6: ...the next scheduled action to heat up the domestic hot water tank Then you can activate powerful operation The domestic hot water tank will start heating up the water to the Comfort temperature INFORM...

Page 7: ...You can program up to 6 actions each day 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon 4 Confirm the changes To copy the schedule to the other weekdays 1 Select Monday Mon Sat Wed Fri Thu Tue...

Page 8: ...n Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule INFORMATION Not all schedules can be renamed 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Se...

Page 9: ...ice C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minutes...

Page 10: ...er periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a prese...

Page 11: ...ature cannot be reached Increase the desired leaving water temperature in accordance with the heat emitter type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran ou...

Page 12: ...rs or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently venti...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P495247 1C 2018 11 Copyright 2017 Daikin 4P495247 1 C 00000003...