Summary of Contents for altherma EJHA04AAV3

Page 1: ...Operation manual Daikin Altherma hybrid monobloc Heat pump module English Operation manual Daikin Altherma hybrid monobloc Heat pump module EJHA04AAV3...

Page 2: ...om The system is making gurgling noises after commissioning 12 9 Disposal 12 10 Glossary 12 1 About this document Thank you for purchasing this product Please Read the documentation carefully before o...

Page 3: ...omestic hot water tank a b c e f d B C A Gas boiler third party instant domestic hot water not for Switzerland a b c e f d B C A A Living room B Bedroom C Technical room Example Garage a Outdoor unit...

Page 4: ...ce operation mode Heating Not available Icon Description Heat pump compressor operation or boiler operation This symbol is related to the home page Desired room temperature preset value Comfort daytim...

Page 5: ...oom temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or permanent To set the overrule period Prerequisite...

Page 6: ...Detailed 15 20 60 C Storage comfort Tank Mon 15 20 60 C 00 00 Mon Tue Tank Storage comfort To read out and adjust the desired reheat temperature in scheduled and reheat mode 1 Go to 7 4 3 3 User sett...

Page 7: ...or Monday Use and to select an entry Use and to change the value of an entry To copy from one day to another 1 Select the day from which you want to copy and press Example Monday 2 Select Copy day and...

Page 8: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of meas...

Page 9: ...ontact helpdesk number 4 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for elec...

Page 10: ...ace itself based on an internal calculation consumed gas only in case of HY2KOMB28 32AA gas boiler calculated by the interface itself based on an internal calculation 5 1 To view the energy statistics...

Page 11: ...rce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside th...

Page 12: ...s will appear on the user interface Possible cause Corrective action Heat pump is damaged Press to view a description of the problem Press again Select to allow the gas boiler to take over the entire...