background image

Control Manual

CLIV  Series

Air Cooled Fixed Compressor Chiller 

Water  Generator Unit

Model
3, 5 y 10  TR 
Refrigerant HFC-410A
50/60 Hz

CM

Group: Chiller

Part Number: CM CLIV 

Date: 10 November 2022

Summary of Contents for Clima-Flex CLIV Series

Page 1: ...Control Manual CLIV Series Air Cooled Fixed Compressor Chiller Water Generator Unit Model 3 5 y 10 TR Refrigerant HFC 410A 50 60 Hz CM Group Chiller Part Number CM CLIV Date 10 November 2022...

Page 2: ...escription 4 Features Benefits 5 Control 7 2022 Clima Flex Illustration and data cover the Clima Flex product at the time of publication and we reserve the right to make changes in design and construc...

Page 3: ...tial choking danger as the refrigerant will displace air in the immediate area Be sure to follow all applicable published industry related standards and local state and federal statutes regulations an...

Page 4: ...120 000 AIR DISCHARGE HD Horizontal Discharge OPERATION C Cooling Only H Heat Pump UNITS 1 Stand alone CONDENSER FAN A Axial Fixed ANTICORROSION C Coat in Condenser I Coat in Components M Total Coati...

Page 5: ...t All main components are rigorously tested and validated before being installed Each designed unit has undergone long hours of rigorous testing to ensure the efficiency safety durability and quality...

Page 6: ...eas of the coating surface with no bridging of material between fins Therefore ES2 pigments are suitable for even the most Spray for coating hvac r products Ideal applications for Insitu spray applied...

Page 7: ...hows 3 digits with a decimal point between them only the decimal point will be shown in the range from 99 9 to 99 9 outside this range the values will be shown without decimal point using the 3 digits...

Page 8: ...larm The Flow Alarm is activated when Low Flow is detected to reset the alarm and correct the problem Reset the unit Turn the unit off and on A1 Freeze Alarm Temperature sensor B3 measures a temperatu...

Page 9: ...nnectivity with mobile devices and comes integrated on panel mounted models and is purchased separately on DIN rail mounted models The CAREL APPLICA app available on Google Play for the Android operat...

Page 10: ...lization At startup the user terminal briefly displays the text NFC which indicates the presence on the user terminal of the NFC interface for communication with mobile devices and then the standard d...

Page 11: ...maintenance intervention is required the alarm code indicates which device is concerned The reset of some alarms can be configured through a parameter The configurable alarms are High pressure switch...

Page 12: ...ontrol will be mentioned below These alarms will depend on the electrical configuration and the model of the equipment and depending on these configurations the alarms shown below may or may not depen...

Page 13: ...ress DOWN the unit on off command UnSt appears Press DOWN the command to change the cooling mode so Clo at Assistance level and for A W reversible units appears heating H ModE only for heat pump units...

Page 14: ...l address Electrical diagram label Name ID1 IF Flow sensor ID2 C H Heating cooling switch ID3 AP High pressure switch ID4 BP Low pressure switch ID5 System DAC HDunit ON OFF switch Tabla 2 Digital inp...

Page 15: ...cm cliv cf eng www clima flex com 15 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...cm cliv cf eng www clima flex com...

Reviews: