INSTALLATION AND

OPERATION MANUAL

EKMBUHBA6V3

Heater kit for air to water heat pump system

4PW58903-1A_digital.book  Page 1  Friday, September 17, 2010  11:37 AM

Summary of Contents for EKMBUHBA6V3

Page 1: ...INSTALLATION AND OPERATION MANUAL EKMBUHBA6V3 Heater kit for air to water heat pump system 4PW58903 1A_digital book Page 1 Friday September 17 2010 11 37 AM...

Page 2: ...2 170 350 376 266 500 85 220 575 1 230 535 3 200 300 500 250 350 NOTES 2 1 3 4PW58903 1A_digital book Page 1 Friday September 17 2010 11 37 AM...

Page 3: ...l Installer Technical skilled person who is qualified to install products as per the subject of this manual User Person who is owner of the product and or operates the product Service company Qualifie...

Page 4: ...e a fire Where the air contains high levels of salt Where voltage fluctuates a lot such as that in factories In vehicles or vessels Where acidic or alkaline vapour is present DANGER ELECTRICAL SHOCK S...

Page 5: ...eat exchanger 3 Pump 4 Shut off valve 5 Heater kit 6 Motorized 3 way valve optional 7 Domestic hot water tank optional 8 Collector field supply 9 By pass valve field supply 10 Radiator field supply 11...

Page 6: ...ation Therefore it is advisable to install the heater kit on a firm wall and not in nor close to a sound sensitive environment e g bedroom Do not install the heater kit in places with high humidity e...

Page 7: ...d wiring 2 1 1 3 4 1 1 NOTICE Be careful not to deform the heater piping by using excessive force when connecting the piping Deformation of the piping can cause the heater to malfunction NOTICE Make s...

Page 8: ...n International Technical Standard setting the limits for voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 75 A Item Cable bundle...

Page 9: ...7 START UP AND CONFIGURATION 7 1 Pre operation checks After the installation of the heater kit check the following before switching on the circuit breaker Filled with water Make sure that the heater...

Page 10: ...inspections on the heater kit and the field wiring have to be carried out at regular intervals This maintenance should be carried out by your local Daikin technician The described checks must be execu...

Page 11: ...ut any maintenace or repair activity always switch off the circuit breaker on the supply panel or remove the fuses Do not touch water pipes during and immediately after operation as the pipes may be h...

Page 12: ...4PW63549 1 08 2010 Copyright 2010 Daikin 4PW58903 1A_digital book Page 1 Friday September 17 2010 11 37 AM...