background image

English

Air purifier

Floor standing type

Model

MC80ZBFVM

OPERATIONAL MANUAL

Streamer Air Purifier

For Internal Use only

3P690982-3A

•  Thank you for purchasing this air purifier.
•  Please read the operation manual carefully and follow it for correct use.

• 

Please read the "Safety Precautions" section before use.

 

 

Page 3-5

  Please keep the operation manual in a safe place for later reference.

Summary of Contents for MC80ZBFVM

Page 1: ...urifier For Internal Use only 3P690982 3A Thank you for purchasing this air purifier Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section...

Page 2: ......

Page 3: ...18 Changing the Airflow rate 19 Operating MODEs 19 AUTO FAN ECONO ANTI POLLEN CIRCULATOR Maintenance Quick Guide for Maintenance 27 Dust Collection Filter Replace 29 Streamer Unit Replace 30 When Not...

Page 4: ...wer supply plug or cord etc If the power supply plug or cord is damaged it must be replaced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard An electric s...

Page 5: ...r spray insecticide etc near the unit Do not wipe the unit with benzine or thinner An electric shock fire or cracking may result Immediately turn off and unplug the unit if there are any signs of abno...

Page 6: ...r have taken sleep medication should not operate the unit An electric shock injury or poor health may result Do not use combustion based heating devices in places directly exposed to airflow from the...

Page 7: ...netic cooker speakers etc The unit may not function correctly Do not expose to direct hot air from heating appliances or near combustion appliances The unit may not be able to indicate correct humidit...

Page 8: ...sensor Inside the air inlet right side Temperature sensor Humidity sensor Inside the air inlet right side PM2 5 sensor Inside the air inlet right side Page 9 23 24 27 33 35 Wireless LAN connection ada...

Page 9: ...ached Main Removable Parts Streamer unit cover Page 30 Streamer units 2 units Page 30 Pre filter Page 27 SSID KEY sticker can be checked if the pre filter is removed Dust collection filter white filte...

Page 10: ...ds regardless of humidity level PM2 5 sensor lamp Indicates the volume of ambient dust by 3 lamp colours Blue Orange Red Blue indicates clean air Lamp colour Blue Orange Red PM2 5 concentration g m3 0...

Page 11: ...d heating devices AIR MONITOR indicator white estimate values Indicates what setting is selected with to display Settings at time of purchase g m3 g m3 PM2 5 concentration Displays the concentration o...

Page 12: ...is unplugged when Child Proof Lock is active Child Proof Lock will turn off BRIGHTNESS button During operation each press cycles through operating panel lamp brightness levels Please use if lamp brigh...

Page 13: ...ress to cycle between FAN settings Page 19 Communication lamp Communication ON OFF button Used when operating the air purifier via smartphone Each press cycles between communication ON and OFF The Com...

Page 14: ...tion To avoid staining of walls position the unit in accordance with the positioning measurements in the illustration However please note that since this unit draws in dirty air certain types of wall...

Page 15: ...odorising filter With the deodorising filter installed Deodorising filter Gap on the left and right Dust from the deodorising filter may turn the dust collection filter black but it does not affect du...

Page 16: ...LAN equipment or microwave ovens may affect wireless LAN communication This product cannot be directly connected to the communication line of a telecommunications carrier Internet provider etc When c...

Page 17: ...ment Operation of the air purifier can be started and stopped by pressing the buttons on the air purifier itself even when it is being operated from outside the home Do not operate the air purifier re...

Page 18: ...lit Wireless LAN connection adaptor function is OFF If the unit air purifier can t be found with the app Perform connection settings again Move the router closer to the air purifier If you want to tur...

Page 19: ...sted to 4 positions Approx 80 Approx 70 Using the Air Purifying Operation turning operation ON OFF Cleans the air in the room Press Press again to turn OFF Attention Do not move the unit or attach or...

Page 20: ...w Standard Turbo About FAN settings Quiet A gentle breeze is emitted Recommended to use this during sleep hours To quickly eliminate odours from a room it is recommended that the FAN setting be set to...

Page 21: ...stops periodically Dust and odours are monitored The following functions are turned OFF to further reduce power consumption Streamer OFF If dust or odours are detected FAN setting switches automatical...

Page 22: ...he Streamer output be set to Normal as deodorising capacity is reduced when set to Low Can be performed either during operation or while operation is stopped Press for about 5 seconds and when a short...

Page 23: ...owever it is unlit during Monitoring mode It is unlit when the setting condition of Streamer is OFF Press A short beep sounds with the ANTI POLLEN MODE lamp blinking while the FAN lamp blinks accordin...

Page 24: ...n Release both and when a short beep sounds CIRCULATOR MODE lamp will light up after blinking Blinking Lit up According to the current setting the FAN lamp will turn from blinking to lit up Normal Low...

Page 25: ...etting is now complete Power supply plug Power socket If this procedure is not performed the unit will not return to the regular operation mode Settings are remembered even if the unit is unplugged Pr...

Page 26: ...p Quiet blinks then lights up Blinking Lit up According to the current setting the ECONO MODE lamp will be displayed as follows Blinking Lit up ON Unlit OFF Airflow rate range for AUTO FAN MODE 4 Leve...

Page 27: ...ply plug Power socket If this procedure is not performed the unit will not return to the regular operation mode Settings are remembered even if the unit is unplugged Press MODE to change the setting T...

Page 28: ...ards you to remove it 1 Place your finger on the top centre side of the pre filter and push down to remove the hook 2 Pull it towards you to remove Insert the hooks 2 places into the unit then press u...

Page 29: ...ghtly vacuum the dust on the surface that doesn t have the tag Be careful as the filter is easily damaged In case filter is damaged or holes are opened on the surface dust collecting performance decre...

Page 30: ...iation JEM1467 standard If the impurity content of the ambient air is high the filter will need more frequent replacement Replace the dust collection filter if the filter is failing to perform Purchas...

Page 31: ...Pull it out while pushing the hook The lock will not release unless the hook is pushed Breakage may result from forcibly pulling 4 Attach the new Streamer units 1 Pay attention to the direction of the...

Page 32: ...ed Period 1 Unplug the power supply 2 Clean the parts Page 28 29 In particular parts cleaned with water should be completely dry Mould may result from remaining moisture 3 Cover the air outlet and oth...

Page 33: ...the pre filters dust collection filter attached These lamps may blink if the unit is operated without a part attached If all parts are attached Electrical parts are faulty If one or more parts are not...

Page 34: ...sult Replace it or vacuum away dust with a vacuum cleaner if dirt buildup is severe Page 28 29 In some cases odour is stuck to the dust collection filter depending on the location where the unit is us...

Page 35: ...Low Page 21 22 Whistling and fluttering sound during operation Is there a buildup of dust on the pre filter Clean this part Page 27 Is the dust collection filter clogged up Please perform maintenance...

Page 36: ...ned by odour levels in the first minute approx after the power supply plug is inserted every time Page 10 To adjust the basic sensitivity of the odour sensor unplug the power supply when the air is cl...

Page 37: ...e room the unit was previously in may still be present Keep operating until the odour disappears Are odours coming from the deodorising filter or dust collection filter Please conduct maintenance on e...

Page 38: ...t switches to Monitoring mode during operation in ECONO MODE the fan turns on and off repeatedly Page 20 Are the pre filters filter fixing unit and dust collection filter attached before the unit is o...

Page 39: ...0V and 60Hz 220 230V Even when the power is off approx 1W 4 of power is consumed to run the microcomputer This appliance is designed to be used in residential or commercial areas A weighted emission s...

Page 40: ...tion filter made of polyester and polypropylene Disposal requirements Your product is marked with this symbol This symbol means that electrical and electronic products shall not be mixed with unsorted...

Page 41: ...MEMO...

Page 42: ...MEMO...

Page 43: ...MEMO...

Page 44: ...ail The manufacturer reserves the right to revise any of the specification and design contain herein at any time without prior notification All images are for illustration purposes only Lot 60334 Pers...

Reviews: