background image

DHOS-CS-IM-2107004D 

          

 

 

 

 

 

 

 

Reiri for Home  

(Lite Version) 

 

 

Installation Manual 

 

Model 

DCPH02

 

 

 

 

 

 

 

 

 

 

Reiri for Home (Lite Version) Lite is smart centralised controller that provide AC solution for 
residential application. It offers full control of Daikin air-conditioning system in one screen through 
Reiri for Home (Lite Version) mobile app. 

Summary of Contents for Reiri for Home Lite

Page 1: ...on Manual Model DCPH02 Reiri for Home Lite Version Lite is smart centralised controller that provide AC solution for residential application It offers full control of Daikin air conditioning system in...

Page 2: ...be met 4 2 2 Connecting a LAN cable 5 2 2 1 Terminal Location and Conceptual Connection Diagram 5 2 2 2 Requirements that must be met 5 2 3 Connecting to Modbus device s by USB Ports 5 3 Reiri Control...

Page 3: ...DHOS CS IM 2107004D 4 DCPA01 Installation to ODU IDU 39 5 Finding Network Information Gateway DNS Subnet 41...

Page 4: ...located Check that an appropriate space for installing the Reiri for Home Lite Version is available 1 1 Checking that all accessories are included Based on the following accessory list check that all...

Page 5: ...DHOS CS IM 2107004D 2 1 2 Understanding external dimensions Top face OF Reiri for Home Lite Version Rear face of Reiri for Home Lite Version...

Page 6: ...priority USB 2 0 Type A port B2 USB 2 0 2nd priority USB 2 0 Type A port C LAN 1 GbE speed LAN D RS485 1 x RS485 port E Micro USB Micro USB power connector 5V DC power input NOTE Please connect all t...

Page 7: ...eptual Diagram Connect DCPA01 to Reiri for Home Lite Version via the RS485 port Take note of the polarity of the ports as shown in the picture below Connect a pair of RS485 cable from the port to DCPA...

Page 8: ...rements that must be met Applicable cable standard CAT 5 5e 6 Connector standard RJ 45 2 3 Connecting to Modbus device s by USB Ports Reiri for Home Lite Version comes with 2 USB ports for connection...

Page 9: ...devices and settings to connect the devices to Reiri controller 4 Customise the point attributes for the projects Chapter 3 4 Please ensure that the following ports are opened before setting up Reiri...

Page 10: ...o download app a Connect the smartphone by WiFi to the router with internet access b Launch the app c Reiri Setup Tool start up page will show up Tap on target controller to login If the controller is...

Page 11: ...controller with username and password For first time login use setup as username and no password This special account will disappear once a user account is created e Tap User Account Management then t...

Page 12: ...h Controller settings is important for the setting the identification of this controller in Reiri user app Tap Controller Settings in the main menu after login Refer to Chapter 3 5 2 Controller Settin...

Page 13: ...sed information such as history scheduling etc Tap on Time Date to enter Refer to Chapter 3 5 3 Time and Date for details Set Controller Name Location and Floor Size for identification of this control...

Page 14: ...DHOS CS IM 2107004D 11 j Activate controller to release the controller for use by user app Tap on Activate Controller to enter Refer to Chapter 3 5 4 Activate Optional Function for details...

Page 15: ...ed at customer s site Chapter 3 5 4 Activate Optional Function can be done at other locations where access to internet is available Bring controller back to customer site after completion of Chapter 3...

Page 16: ...the Reiri controller Plug the USB adaptor back and power back the controller For Reiri for Home Lite Version these are the connectable devices 1 DCPA01 DTA116A51 for DIII Net enabled air conditioning...

Page 17: ...nt devices provide various types of information forming the points Points will need to be customised to identify the use easily Chapter 3 7 Point Settings will explain the point attributes for customi...

Page 18: ...class is used when other Reiri controller access Reiri for Home using Reiri Controller function NOTE Admin account can also be created in the user app Connection Class Settings 3 Enter Password and r...

Page 19: ...word Only logged in user can change the account password 1 Tap on username to delete Password at least 10 characters A mixture of uppercase lowercase numbers and special characters Minimum 2 types Do...

Page 20: ...ection is disabled app connects to this controller by Local Area Network LAN Recommend to enable This setting will only take effect after a reboot NOTE Internet access MUST always be available on the...

Page 21: ...ttings get the static address subnet mask gateway DNS of the LAN from a person who manage this LAN Otherwise refer Chapter 5 Finding Network Information Gateway DNS Subnet This setting will only take...

Page 22: ...at login screen and in Multi Site Management MSM This setting will only take effect after a reboot 3 Domain name of this SMTP server For example for Gmail is gmail com 4 Enter username and password o...

Page 23: ...lable on the connected network for Internet Time Synchronization with Internet Time Server If controller have no internet access cannot access internet time servers user can manually set the date and...

Page 24: ...cations where access to internet is available Bring controller back to customer site after completion of Chapter 3 5 4 Activate Optional Function 1 Set Activator Account An activator account has to be...

Page 25: ...This function is to activate the controller to use with the user app NOTE Internet access MUST be available on the connected network for activation 1 Tap Activate Controller 2 Tap Ok to continue Cont...

Page 26: ...e option feature this QR code has to be scanned first Then tap scanned software ID to activate the option NOTE Internet access MUST be available when activating options 2 Present the QR code for optio...

Page 27: ...ng option ID is activated the activated option can be deactivated from controller and the deactivated ID can be reused 3 Upon successful scan of the QR code the software ID will be listed in the List...

Page 28: ...equired to be used by other activators the option key will need to be removed from the app 2 Tap Ok to continue Option will be removed from controller 1 Tap on the Option name Finally Option Key ID is...

Page 29: ...bled the menu bar of Reiri for Office Mobile and Windows App will show the IAQ Monitoring icon IAQ Monitoring room configuration can be added in the Reiri for Office User App Refer to the document Rei...

Page 30: ...l required devices first before rebooting Management points will show up in Point Settings only after reboot Tap below respective devices to open the connection details input for the device 1 Enter de...

Page 31: ...DTA116A51 first using the DIP switches DS1 DS2 as shown below DS1 Communication Parameters Fixed Default Values Baud Rate 19200 Parity Even Stop Bit 1 DS2 Address Setting Only 1 DCPA01 can be connecte...

Page 32: ...nfirm and save changes 2 Tap to select 1 for the address Only 1 DCPA01 allowed 3 Select the connected RS 485 which is port 1 1 ID is to identify the port location of the device Set the value to 1 4 Va...

Page 33: ...ule is the Wi Fi control module for residential air conditioning units from DAMA factory Refer to DAMA IOT module manual to setup the module Confirm the DAMA cloud login account and password after reg...

Page 34: ...ze the point attributes to use the data correctly Name Display icon and other parameters can be customized to indicate the behavior of the point To go manage individual points 2 Tap on point name to v...

Page 35: ...he point types and usage Device Point Type Point Usage Air conditioner inclusive AHU Ac ac HRV Hrv hrv Temperature Measurement Value temp Relative Humidity measurement Value humi CO2 measurement Value...

Page 36: ...ult is Disabled E g WAGO IO points that are not connected with any device can be set to Point Not In Use Record to History All Status change information is stored in History DB Store Data to DB All Op...

Page 37: ...ll not convert In case of WAGO Ai or Ao is used min and max have to set actual min and max value For example CO2 sensor which min value is 400 and max value is 5000 Then min has to set to 400 and max...

Page 38: ...DHOS CS IM 2107004D 35 AC Management Point Delete point only when point is no longer in use Irreversible action FINALLY Tap Save to save changes...

Page 39: ...ainly used when users wanted to replicate controller settings into a set of other controllers Do note that these functions work only on Windows software Backup 1 Tap Backup to enter 2 Tap Please selec...

Page 40: ...D 37 Restore 1 Tap Restore to enter 2 Tap Please select data backup folder to select destination folder for restoring 3 Tap Start on either Settings or Database or both to restore 4 Tap OK 5 Restore i...

Page 41: ...This tool can be found on the main page of the setup tool when you open the software refer to the picture below Note this function only available on the Windows version 1 Select controller to remove...

Page 42: ...on to ODU IDU The DCPA01 adaptor is an interface device to translate between DIII Net and Modbus protocols for DIII Net enabled indoor unit monitoring and control Through Modbus communication Reiri ca...

Page 43: ...ty Stop Bit 2 Non Parity 4 Parity Even Odd Parity setting will enable when DS1 3 is off DS2 1 4 Slave Address 0 No Modbus communication 1 15 Slave Address 1 15 OFF 0 ON 1 1 off 2 off 3 off 4 on 0001 i...

Page 44: ...ng a computer In Windows run command prompt At the command line enter ipconfig all and press enter Look for the connected device WiFi adaptor card or Ethernet card and record the details for controlle...

Reviews: