background image

English

Français

Español

OPERATION MANUAL

MODEL

REYQ72XATJU

REYQ96XATJU

REYQ120XATJU

REYQ144XATJU

REYQ168XATJU

REYQ192XATJU

REYQ216XATJU

REYQ240XATJU

REYQ264XATJU

REYQ288XATJU

REYQ312XATJU

REYQ336XATJU

REYQ360XATJU

REYQ384XATJU

REYQ408XATJU

REYQ432XATJU

REYQ456XATJU

REYQ72XAYDU

REYQ96XAYDU

REYQ120XAYDU

REYQ144XAYDU

REYQ168XAYDU

REYQ192XAYDU

REYQ216XAYDU

REYQ240XAYDU

REYQ264XAYDU

REYQ288XAYDU

REYQ312XAYDU

REYQ336XAYDU

REYQ360XAYDU

REYQ384XAYDU

REYQ408XAYDU

REYQ432XAYDU

REYQ456XAYDU

REYQ72XAYCU

REYQ96XAYCU

REYQ120XAYCU

REYQ144XAYCU

REYQ168XAYCU

REYQ192XAYCU

REYQ216XAYCU

REYQ240XAYCU

REYQ264XAYCU

REYQ288XAYCU

REYQ312XAYCU

REYQ336XAYCU

REYQ360XAYCU

REYQ384XAYCU

REYQ408XAYCU

REYQ432XAYCU

Read these instructions carefully before installation. 
Keep this manual in a handy place for future reference. 
This manual should be left with the equipment owner.

Regarding the operation procedures of the remote controller, 
refer to the manual included to the corresponding remote controller.

VRV  

System air conditioner

3P477778-8G

00_CV_3P477778-8G.indd   1

12/12/2018   3:29:15 PM

Summary of Contents for REYQ72XATJU

Page 1: ...REYQ384XAYDU REYQ408XAYDU REYQ432XAYDU REYQ456XAYDU REYQ72XAYCU REYQ96XAYCU REYQ120XAYCU REYQ144XAYCU REYQ168XAYCU REYQ192XAYCU REYQ216XAYCU REYQ240XAYCU REYQ264XAYCU REYQ288XAYCU REYQ312XAYCU REYQ33...

Page 2: ...eakage electric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a professional Contact your dealer to move and r...

Page 3: ...result in incomplete combustion or deformation of the unit due to the heat Do not expose the controller to direct sunlight The LCD display can become discolored and may result in fail to display the...

Page 4: ...unless you are licensed to do so Consult with your local dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure to use...

Page 5: ...REYQ144XAYCU REYQ168XAYCU REYQ192XAYCU REYQ216XAYCU REYQ240XAYCU REYQ264XAYCU REYQ288XAYCU REYQ312XAYCU REYQ336XAYCU REYQ360XAYCU REYQ384XAYCU REYQ408XAYCU REYQ432XAYCU Contents Safety Considerations...

Page 6: ...inal cooling Maximum capacity Btu h 72 000 96 000 120 000 144 000 168 000 Nominal heating Maximum capacity Btu h 81 000 108 000 135 000 162 000 188 000 Dimensions H W D inch mm 66 11 16 1694 48 7 8 12...

Page 7: ...Note The Cool Heat selector cannot connect to the multi Branch Selector unit Operation Range COOLING HEATING Outdoor temperature 23 to 110 FDB 5 to 43 CDB 13 to 60 FWB 25 to 16 CWB Indoor temperature...

Page 8: ...ler For more information see the operation manual that came with the remote controller Operation Procedure Operation procedure varies according to the combination of outdoor unit and remote controller...

Page 9: ...icates the available operating modes of the other indoor units on the system based upon the selected mode of the master indoor unit When the master indoor unit is set to The other indoor units in the...

Page 10: ...t Filter Indicator Air Flow Direction Ventilation Schedule Off Timer Celsius Fahrenheit 1 2 Cool Set to Cool 74F Press buttons to select Reset Filter Indicator on the main menu screen and press Menu O...

Page 11: ...r code and model name or code Precautions for Group Control System or Two Remote Controller Control System This system provides two other control systems beside individual control one remote controlle...

Page 12: ...temperature We recommend starting the operation in advance using schedule operation Seasonal Maintenance Caution Do not touch the air inlets or aluminum fins of the outside or indoor units Touching th...

Page 13: ...utomatically restarts when the noise goes away Cool heat cannot be changed over When the display shows MASTER CONTROLLED It shows that this is a slave remote controller When the Cool Heat selector swi...

Page 14: ...e make this noise A low sound like dripping water is heard while the indoor unit is stopped When the other indoor unit is in operation this noise is heard In order to prevent oil and refrigerant from...

Page 15: ...oblem after checking all the above items contact your local dealer Let them know the symptoms system name and model name 1 If the system does not operate at all Check if there is no power failure Wait...

Page 16: ...ate and installation date Malfunction Inform the staff of the defective details Malfunction code being displayed on the remote controller Name address telephone number Repair after the warranty term i...

Page 17: ...n locations where power fluctuation voltage frequency wave distortion etc is high Cannot be used if it is outside the allowable range 3 When installed and used in locations where bumps and vibrations...

Page 18: ...aler for discarding this unit since it is required by law to collect transport and discard the refrigerant in accordance with chlorofluorocarbon collection and destruction law Where to call For after...

Page 19: ...3P477778 8G EM18A016 1901 HT 00_CV_3P477778 8G indd 2 12 12 2018 3 29 15 PM...