background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operator’s Manual

 

 

For the DM100-2014 VDR 

 

Document Number  DBS11011 

Version Number 

1.2 

                           

Date 

 

June 2014 

 

 

P/N (hard copy) 

9302721-12 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DM100-2014

Page 1: ...Operator s Manual For the DM100 2014 VDR Document Number DBS11011 Version Number 1 2 Date June 2014 P N hard copy 9302721 12 ...

Page 2: ...al for the DM100 2014 VDR Copyright Danelec Marine A S Revision record Version Date Description 1 0 April 2014 Original issue of document 1 1 May 2014 Minor revision 1 2 June 2014 Minor revision DBS11011 12 Page 2 27 ...

Page 3: ...dge Control Panel 9 3 1 1 Alarm display 9 3 1 2 Self test Operational Performance Test 9 3 1 3 Setting the display brilliance level to default 9 4 OPERATION OF THE DM100 DAU 10 4 1 Data Processing Unit DPU 11 4 1 1 Power LEDs 11 4 1 2 AC breaker 11 4 1 3 AC inlet 11 4 1 4 Battery switch 12 4 1 5 VDR status LED 12 4 1 6 Main CPU LED 12 4 1 7 LEDs in the Ethernet connectors 12 5 OPERATION OF THE NON...

Page 4: ...16 6 1 6 MR address 16 7 OPERATION OF STANDARD RVI 02 004 AND RVI 02 004D POE 17 7 1 Operation of RVI with AC power supply 18 7 1 1 RVI address 18 7 1 2 Ethernet ports 18 7 1 3 ST LED 18 8 ERROR CODES 19 8 1 Error codes 19 9 SERVICE AND MAINTENANCE 27 9 1 Verification of the VDR functionality following service on any sensor 27 9 2 List of most common spare parts 27 DBS11011 12 Page 4 27 ...

Page 5: ...00 2014 VDR DBS10919 Installation Manual for Remote Video Interface with PoE RVI 02 004 RVI 02 004D 9200327 Installation Manual for DM400 DM500 VDR Sensor Interface Unit 9200331 Installation Manual for Remote Video Interface for DM200 DM300 DM400 DM500 1 2 Terms and Abbreviations BCP Bridge Control Panel BMU Bridge Microphone Unit DAU Data Acquisition Unit DPU Data Processing Unit located inside t...

Page 6: ...st be carried out regularly VDR system errors will also be shown here as a caution steady yellow light 2 1 3 Bridge Microphone Units BMU A number of BMUs must be installed on the bridge console ceiling or bulkhead mounted Watertight outdoor BMUs for the bridge wings are available BMU BMU BMU BMU BMU DAU Fixed Capsule BMU SIU Digital inputs 64 BCP Ethernet STP CAT5 VHF 6 x BMU Serial inputs 8 Video...

Page 7: ...ple a RADAR which is unable to send images to the VDR using Ethernet i e typically older equipment The RVI must be installed indoors normally close to the RADARs It must be connected to the DAU with a cable which may be up to 100m in length 2 1 7 Sensor Interface Unit SIU The SIU is optional equipment An SIU is needed if for example door status cannot be provided using a serial or Ethernet interfa...

Page 8: ...below Type of input Maximum configuration Ethernet interfaces 7 on DAU Serial inputs 40 12 on DAU 3 modules Analog inputs 32 2 modules Digital inputs 128 8 modules Audio inputs 14 10 on DAU 4 on RAI Video inputs 4 2 RVIs For configuration of the VDR acquiring network data and acquiring image data The VDR records up to 8 image tracks Four of these tracks may be used for recording images acquired by...

Page 9: ...wledged Alarm messages will be cleared and the caution indicator turned off when the cause of error is resolved 3 1 2 Self test Operational Performance Test An Operational Performance Test OPT of the VDR must be carried out regularly and always after service and maintenance which may affect the operation of the VDR An OPT is best done while the vessel is en route and all navigation equipment is sw...

Page 10: ...l is only relevant during installation and service VDR status LED AC inlet Program memory I F to IAS I F for BCP Service console Ethernet ports VGA interface Audio interfaces DPU AC breaker Power status LEDs Battery switch Interfaces for serial data Termination resistors for SI00 SI03 Main CPU status LED Service mode switch I F for capsule I F for RDI I F for RVI I F for SIU I F for float free DBS...

Page 11: ...AC power failed Error ERR LED red Steady light The internal power control circuit has failed Error Off The internal power control circuit is operating OK OK LED blue Steady light Power to DPU present OK Off No power to the DPU Error note 1 4 1 2 AC breaker The AC breaker is a combination of a fuse and a manually operated switch i e it can be used to manually switch off the AC power sources but it ...

Page 12: ...ormation displayed contains information about system errors which prevent normal operation Contact a service agent if the problem cannot be rectified Error 4 1 6 Main CPU LED The main CPU LED is controlled by the power control circuit which will become active as the first circuit after power is applied The power circuit uses the LED to show information about the main CPU OFF The power circuit has ...

Page 13: ...AC is present 5 1 2 AC breaker The AC breaker is a combination of a fuse and a manually operated switch i e it can be used to manually switch off the power source but it will also pop out automatically if too much current is drawn from the power source Serial I F Analog I F Digital I F Ethernet port UR address AC inlet Uni Rack AC Breaker AC LED Ethernet link and activity indicators DBS11011 12 Pa...

Page 14: ... activity indicators The LINK LED right will be illuminated yellow when a communication link is established to the DAU The ACT LED left will flicker green depending on the traffic load 5 1 4 UR address Must be set to 0 for the first SIU and 1 for an additional second SIU DBS11011 12 Page 14 27 ...

Page 15: ...has detected a module in the corresponding slot 6 1 3 AC breaker The AC breaker is a combination of a fuse and a manually operated switch i e it can be used to manually switch off the power source but it will also pop out automatically if too much current is drawn from the power source Link indications for slots Ethernet ports MR address Serial I F module Analog I F module Digital I F modules AC i...

Page 16: ... Please notice that the behavior of the LEDs is different from other parts of the system for example the DAU 6 1 5 Allocation of system labels for digital interfaces Card number in VDR configuration Interface number in VDR configuration and VDR Explorer Digital I F module in Slot 3 1 DI00 DI15 Digital I F module in Slot 4 2 DI16 DI31 Digital I F module in Slot 5 3 DI32 DI47 Digital I F module in S...

Page 17: ...2 004D for image capture Another type exists see section 7 1 which may be used if the Power over Ethernet ports on the DPU are used for other purposes RVI 02 004 RVI 02 004D RVI 02 004 D rear panel Ethernet link and activity Green Ethernet link and speed Yellow Ethernet port with PoE RVI address Must be set to 0 for the first RVI and 1 for a second RVI DBS11011 12 Page 17 27 ...

Page 18: ... for the first RVI and 1 for a second RVI 7 1 2 Ethernet ports ETH A must be connected to the DAU Note that the LEDs in the Ethernet connectors RJ45 are inactive for this unit 7 1 3 ST LED The Status LED Yellow will flash 1Hz after power on and then become steady if a communication link is established to the DAU The LED will always be switched off after one minute RVI address Ethernet port ST LED ...

Page 19: ... cable for microphone s reported as faulty Test the inputs on the audio interface module with a spare microphone Replace microphones which are reported faulty if no other error is discovered 058 AUDIO Power short circuit One or more microphones are using too much power The cabling and microphones must be checked 060 STATUS UTC timeout The system is not receiving UTC from the GPS Check that GPS is ...

Page 20: ...1 following system startup The most probable cause is that the power to the RVI is switched off the cable to the RVI from the DPU is disconnected the internal Ethernet cable in the RVI is disconnected or the video interface module is defective 110 AUDIO module 1 Not started The audio data interface module on the SAP board in the DPU cannot be detected following system startup If the error persists...

Page 21: ... on the DPU which is specified in the VDR configuration 152 VIDEO Module in wrong slot The VDR configuration is not consistent with the physical configuration of the VDR for example the additional remote video interface is not connected to the port on the DPU which is specified in the VDR configuration 160 EXTERNAL BACKUP Not recording The system is unable to record data to the extended external b...

Page 22: ...no signal is present check the cable and make sure that the configuration is correct 441 SERIAL module 2 Missing SI08 12 For a DM100 the second serial module is integrated on the SAP board in the DPU The most probable cause is that the SAP board in the DPU is defective 442 ANALOG module 1 Missing AN00 15 If only one module is affected A module has been removed or has failed Check that the module i...

Page 23: ...h the DAU and the SIU power off and then on If the error persists the DPU or the Module rack Uni rack is probably defective 501 DIGITAL module 5 Missing DI64 79 502 DIGITAL module 6 Missing DI80 95 503 DIGITAL module 7 Missing DI96 111 504 DIGITAL module 8 Missing DI112 127 505 SERIAL module 3 Missing SI16 23 506 SERIAL module 4 Missing SI24 31 550 STORAGE Dataset incomplete One or more types of d...

Page 24: ...ause is serious communication problems or a defective fixed capsule 708 CAPSULE Verification failed The VDR found too many data errors within a given interval when verifying the data written to the fixed capsule The fixed capsule is probably defective 709 CAPSULE Record too big The amount of data collected for a 15 second period exceeds the maximum allowed size for the fixed capsule This is typica...

Page 25: ...float free capsule This is typically caused by receipt of too much image data Use the Analysis of recorded data utility on the BCP or in the configurator tool to determine the cause If the problem relates to image data carry out an OPT and check the recorded images 730 FLOAT FREE Record data too big The amount of data received by the VDR has exceeded the capacity of the float free capsule This is ...

Page 26: ...arry out an OPT and check the recorded images 750 LONG TERM Record data too big The amount of data received by the VDR exceeds the capacity of the VDR data disk This is typically caused by receipt of too much image data Use the Analysis of recorded data utility on the BCP or in the configurator tool to determine the cause If the problem relates to image data carry out an OPT and check the recorded...

Page 27: ...58 RVI with PoE for DM100 2 x 5 x BNC 1302365 RVI with PoE for DM100 2 x DVI I 1302373 MK4 capsule with cradle beacon and 50m cable 1302379 VDR Bridge Control Panel BCP 1302389 MK1 float free capsule with 50m cable and junction box 1302646 BMU 003 Bridge Microphone Unit Indoor BMU I 2014 1302647 BMU 004 Bridge Microphone Unit Outdoor BMU O 2014 1302662 Cradle for MK4 capsule 1302726 DM100 DPU DPU ...

Reviews: