background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation manual for 

 

DM800 ECDIS G2 

 

Document Number  DBS11427 
Version Number 

2.1 

 

 

Date 

 

December 2016 

 

 

P/N (hard copy) 

9303423-21 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DM800

Page 1: ...Installation manual for DM800 ECDIS G2 Document Number DBS11427 Version Number 2 1 Date December 2016 P N hard copy 9303423 21...

Page 2: ...BS11427 21 Page 2 67 Revision record Version Date Description 1 0 November 2015 Original issue of document 2 0 September 2016 Updated for DM800 ECDIS G2 version 3 xx and IEC61174 Ed 4 2 1 2016 12 02 U...

Page 3: ...g of other cables 15 3 6 Tool for opening the wire clamps inside the Wago connectors 15 3 7 Termination resistors for IEC 61162 2 16 4 RECOMMENDED STANDARD CONFIGURATION 17 5 SYSTEM CONFIGURATION 18 5...

Page 4: ...chart update 46 7 3 Configuration of virtual data lines via TCP IP 47 8 SERVICE MENU 48 8 1 Service panel 49 8 2 Replacement of defective DPU 50 8 2 1 Replacement of defective DPU with intact SSD 50...

Page 5: ...MISSIONING 59 13 MAINTENANCE SCHEDULE 59 14 LIST OF SPARE PARTS 59 15 APPENDIX A INSTALLATION DRAWING FOR MAIN UNIT 60 16 APPENDIX B INSTALLATION DRAWINGS FOR EK 03 001 KEYBOARD 61 17 APPENDIX C INSTA...

Page 6: ...ose Installation manual for DM800 ECDIS G2 1 1 References DBS11425 User manual for Danelec Marine ECDIS software P N 9303396 DBS11426 User manual for DM800 ECDIS G2 hardware P N 9303424 1 2 Terms and...

Page 7: ...m overview A DM800 ECDIS G2 system consists of the following parts ECDIS DM800 G2 DPU Monitor Keyboard DVD drive and External USB port Alarm panel USB 5 USB 6 USB 7 AP DVI HW KEY USB 8 2 x IEC 61162 2...

Page 8: ...ith USB port The DVD drive is used when installing software and updating charts The USB port on the DVD enclosure may also be used for updating charts There must be easy user access to the DVD drive a...

Page 9: ...ticker showing symbols for the hot key functionality is mounted on the keyboard E g sticker mounted on Cortron keyboard 2 4 Alarm panel The alarm panel includes A buzzer Keys for controlling the volum...

Page 10: ...installation will in most cases consist of a number of systems a cluster In order to ensure redundancy each ECDIS must be connected to two other systems if the cluster contains more than two systems C...

Page 11: ...be possible have redundant network connections if the DM800 ECDIS G2 and DM700 ECDIS are used together Cluster containing 1 x DM700 ECDIS and 1 x DM800 ECDIS G2 Cluster containing 2 x DM700 ECDIS and...

Page 12: ...ECDIS G2 1 2 or 3 Backup ECDIS computers DM700 ECDIS or DM800 ECDIS G2 1 2 or 3 Route planning stations DM700 ECDIS or DM800 ECDIS G2 The maximum cluster size consists of 4 x DM700 ECDIS or DM800 ECD...

Page 13: ...DPU and DVD drive 2 Keyboard w trackball 1 2303578 2301514 2301927 2301514 EK 03 001 KEYBOARD Cortron 564 0094 Cortron 564 0095 KSLM106F1USB WLED 3 ECDIS alarm panel in cabinet 1301365 4 Monitor 1 130...

Page 14: ...ith Item 1 4 IEC AC power connector 1 For connecting AC power to the power supply in the DPU 5 Holder for IEC connector 1 Mount this over the IEC power connector for added support 6 M3 x 10 Pan head P...

Page 15: ...nsumption for the DPU is 60W The power consumption for the Monitor is 50W 3 4 Grounding of data cables All data cables terminated with a Wago terminal block must be shielded with a braid screen Ground...

Page 16: ...16 67 3 7 Termination resistors for IEC 61162 2 Termination resistors may be switched on if needed Key 1 Key 2 Termination resistor On On On On Off Undefined Off On Undefined Off Off Off Termination r...

Page 17: ...data to any ECDIS computer in the cluster With a few exceptions there is no reason to connect a sensor to more than one port in the cluster A GPS Gyro Speed log or devices that can provide similar inf...

Page 18: ...the backup ECDIS 8 Same procedure as for Master ECDIS Initial Configuration of the planning station 9 Same procedure as for Master ECDIS Final configuration of the Master ECDIS 10 Configuration of acc...

Page 19: ...M800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 19 67 5 2 Initial configuration of the Master ECDIS After the startup sequence an ECDIS from the factory will show the configuration wizard...

Page 20: ...tor to be used The wizard will automatically try to detect the monitor connected Select the correct monitor in the drop down list and click on Apply If the resolution looks ok click on Keep changes Cl...

Page 21: ...nstallation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 21 67 Not OK The border of the image should have 3 white lines all the way around OK Not OK Click on Next to continu...

Page 22: ...tion of cluster size Enter the size of the cluster i e how many ECDIS s are to be installed on the vessel Press Next to continue Select node ID and the role of this ECDIS This information must appear...

Page 23: ...rt 3 and 4 are for general purpose It is possible to use the external port for the following features 1 Receiving data typical NMEA strings via TCP IP 2 Transmitting images to a VDR via IEC61162 450 3...

Page 24: ...uipment Transmission of images via IEC61162 450 and synchronization of charts from a NavBox are configured here It requires at least one external network interface to be enabled to work correctly See...

Page 25: ...ble the port 2 Fill in Name with text that identifies the sensor 3 The communication parameters for the serial interface are set according to general accepted standards but can be changed if needed 4...

Page 26: ...ne A S DBS11427 21 Page 26 67 Configuration parameters for an IEC 61162 2 serial port SI00 SI01 Configuration parameters for an IEC 61162 1 serial port with TX SI02 SI03 Configuration parameters for a...

Page 27: ...DIS G2 Copyright Danelec Marine A S DBS11427 21 Page 27 67 5 2 7 Saving the initial configuration Click Apply to save the initial configuration When finished all tasks will be marked with a green chec...

Page 28: ...anual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 28 67 A dialog box for how to utilize ports on other ECDIS s will be displayed but leave this ECDIS for now and configure the rem...

Page 29: ...alizing the configuration The final configuration requires all ECDIS s to have an initial configuration to be operative and to be connected to the cluster 5 3 1 Configuration of access to remote port...

Page 30: ...ent If this is not the case check that all ECDIS s have an initial configuration are operative and connected to the cluster Only ports from other DM800 ECDIS G2 can be shown used Select which ports th...

Page 31: ...uration wizard continue by finalizing the configuration of the remaining ECDIS s 5 4 Configuration of USB hardware key If multiple ECDIS s are used in a cluster one of the USB hardware keys must be se...

Page 32: ...key and make will automatically be made a secondary key in the cluster If charts have been pre ordered make sure to select as primary key the USB hardware key with the same USERPERMIT as used when ord...

Page 33: ...re b Specifying precise positions of sensors onboard The following step must also be performed but may be synchronized between nodes Refer to DBS11425 User manual for Danelec Marine ECDIS software for...

Page 34: ...enu button in the lower left corner of the Chart View 2 The Main Menu panel opens where you can access ECDIS functions and settings 6 3 Service Technician Access Most of the settings that the service...

Page 35: ...es is processed and presented in the ECDIS software Data can also be transmitted to other devices such as autopilot ARPA display and others output devices For the data to be received and transmitted b...

Page 36: ...he sensor is added to the panel and indicators of its main NMEA sentences appear in the Sensors panel 5 Select the sensor to open the sensor parameters panel 6 Set new values for sensor parameters 7 T...

Page 37: ...sition of the sensor between the conning station and the bow a negative Y value indicates the position of the sensor between the conning station and the stern g Mnemonic NMEA sentences to listen to h...

Page 38: ...e sensor parameters panel opens 3 Press the Delete button 4 You are prompted for the MASTER password use the SERVICE password 6 4 4 Available sensors In the table below you can see a list of sensors a...

Page 39: ...l for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 39 67 Sensor Messages Image Radar targets TTM TLL TLB TTD TXT Alert ALR ACK TXT ALF ACM ALC ARC HBT Autopilot APB Navtex NRX NRM TXT...

Page 40: ...on Also the position of the conning station is the starting point of the vessel s velocity vectors and past track 1 Go to Main Menu Settings Vessel Vessel particulars Vessel dimensions and performance...

Page 41: ...n port field 5 Press OK to apply the settings 6 You are prompted for the MASTER password use the SERVICE password Certain ECDIS functions for example manual observation require additional information...

Page 42: ...urce identifier field Source identifier is the talker ID of the primary GPS device used for positioning the own vessel 7 Set the DTE indicator switch to the On position to indicate to an application o...

Page 43: ...DBS11425 User manual for Danelec Marine ECDIS software for description and explanation of how of import IHO certificate permit and ENC chart data 6 8 Displaying of chart data Newly imported data is t...

Page 44: ...ernet port 3 on the DPU may be used to access a local area IP network on the vessel Ethernet port 4 may be used to access a general purpose IP network on the vessel Note that access to a default gatew...

Page 45: ...chart updates 7 2 1 IEC61162 450 Image output The ECDIS supports transmitting a screenshot of the display to a VDR every 15 seconds in accordance with IEC61996 1 Ed 2 Appendix E and the chart informa...

Page 46: ...d the network IEC61996 1 Ed 2 defines the following 1 ECDIS node 1 transmit at time offset 8 seconds 2 ECDIS node 2 transmit at time offset 12 seconds 3 ECDIS node 3 transmit at time offset 2 seconds...

Page 47: ...n to the sensor or as a server the sensor is responsible for establishing the connection to the ECDIS Note TCP IP connections will be disconnected by the ECDIS if no data is received transmitted for 3...

Page 48: ...the ECDIS software To open the panel do the following 1 Open the Main Menu by clicking the menu icon in the bottom left corner 2 In the Main Menu select Settings 3 In the Settings menu select the Sys...

Page 49: ...ial ports Remote I O Section 5 3 1 Configuration of access to remote port USB hardware key management Section 5 4 Configuration of USB hardware key Mouse Trackball configuration Section 5 2 2 Configur...

Page 50: ...SD and the original USB hardware key in the main cabinet do not connect any cables to the Ethernet ports at this time Restore the backup made from the failed ECDIS Connect the cables to the Ethernet p...

Page 51: ...21 Page 51 67 3 Select the USB stick to save the dump for support to 4 Click OK 8 3 2 From the Service Menu 1 Insert a USB stick in the USB port adjacent to the DVD drive 2 Open the Service menu 3 Se...

Page 52: ...scribed below must be executed without hesitation 1 The service CD is needed for re installation of the ECDIS software Power the DPU off and on operate the AC breaker As soon as beeps are heard from t...

Page 53: ...DBS11427 21 Page 53 67 4 After approximately 1 minute this menu will be displayed 9 1 Install ECDIS Boot the system from the service CD as described in section 9 Re installation of ECDIS Click on Ins...

Page 54: ...r the installation to finish You can follow the progress in the info window After the installation is complete the following message is shown Click on Yes The ECDIS will reboot and revert to the facto...

Page 55: ...t parameters Transmission groups Re transmittable binary image transmission group 1 239 192 0 26 60026 Default SFI EI0001 10 4 Supported transmission groups Re transmittable binary image transfer tran...

Page 56: ...through 5 and IEEE 802 3 25 The 8 way modular connector specified in IEC 60603 7 is the 8P8C type that has commonly been used in desktop computer LAN connections and incorrectly but widely referred t...

Page 57: ...tor DVI USB1 USB2 USB3 USB4 USB5 USB6 USB7 USB8 DVD drive External USB port HW KEY Alarm panel AP COM1 1 2 6 5 4 3 ETH1 ETH2 ETH3 ETH4 SI00 SI01 SI02 SI03 SI04 SI05 SI06 SI07 SI08 SI09 SI10 SI11 ECDIS...

Page 58: ...ontains multiple pairs Utilize the galvanic isolated shield if needed C Termination resistors may be switched on see section 3 7 Termination resistors for IEC 61162 2 The cable must be shielded with a...

Page 59: ...ct flash 2303483 EK 03 001 keyboard with 2 trackball kit for stand alone 2303847 EK 03 001 keyboard with 2 trackball kit for console 2303876 Cortron keyboard with 2 trackball table mount kit 2303128 C...

Page 60: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 60 67 15 Appendix A Installation drawing for main unit...

Page 61: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 61 67 16 Appendix B Installation drawings for EK 03 001 keyboard...

Page 62: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 62 67...

Page 63: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 63 67 17 Appendix C Installation drawings for Cortron keyboard Keyboard with brackets for table top mounting...

Page 64: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 64 67...

Page 65: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 65 67...

Page 66: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 66 67...

Page 67: ...Installation manual for DM800 ECDIS G2 Copyright Danelec Marine A S DBS11427 21 Page 67 67 18 Appendix D Installation drawings for Alarm panel...

Reviews: