Products available from DANLERS

•  PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers 
•  Photocells  •  Radio  remote  controls  • Time  lag  switches  •  Outdoor  security  switches 
•  Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products

Please call for more information or a free catalogue, or visit our website.

This product conforms to BS EN 60669-2-1.
Please ensure the most recent edition of the appropriate local wiring regulations are observed 
and suitable protection is provided e.g. 6 amps over current, 1kV over voltage. Please ensure 
that this device is disconnected from the supply if an insulation test is made. 
This product is covered by a warranty which extends to 5 years from the date of manufacture.

Precautions and Warranty 

Installation notes

  Ceiling Surface PIR occupancy switches

 

  CESF PIR

DANLERS ceiling surface passive infra-red  occupancy switches (CESF 
PIR) can be ceiling mounted on a square pattress box (DANLERS 
code: PABO).
The CESF PIR incorporates a passive infra-red quad sensor to detect 
movement of a warm body within its detection zone (diagram A) and 
a photocell to monitor the ambient light level.
Upon detecting movement, if the ambient light is dark enough, the 
CESF PIR will switch the load on. The ambient threshold can be set 
by the user to between approximately 100 lux and infinite lux (photocell 
inactive) via the LUX adjuster (diagram B).
If no more movement is detected within a pre-selected time, then 
the CESF PIR will switch the load off. This time lag can be set via 
the TIME adjuster to 10 seconds, 20s, 40s, 1 minute 15 seconds, 
2m 30s, 5m, 10m, 20m or 40 minutes (diagram B).
CESF PIR also incorporates a sensitivity adjuster, labelled ‘SENS’, 
to reduce the range and sensitivity of detection (diagram B).

Loading

DANLERS CESF PIR units can switch up to 6 amps (1500W) of: 

•  Fluorescent lamps, high frequency or switch start 
•  Incandescent or mains halogen lamps

 (recommended with integral safety fuse) 

•  Electronic or wire wound transformers.

They can also switch up to: 

•  1 amp (250W) of metal halide lamps or fans.

14/05/10

INS944 CESF PIR

Variants

As DANLERS design and manufacture in the UK, variants can be supplied, 

coded by the following suffixes and applied in this order:
•  12V or 24V   

12V or 24V (ac or dc) operation 

•  VF 

 

 

Volt Free contacts 

•  GOLD or LG 

Gold or Logic Gold contacts 

•  NC 

 

 

Normally Closed contacts

Variant details are covered in an enclosed addendum sheet if applicable.

Troubleshooting

 

The load will not switch on:

 

•  The LUX adjuster is set too low and is inhibiting the switch. 

•  The SENS adjuster is set too low. 

•  The moving body is not emitting more IR than the background. 

    (Person wearing insulating clothing in a warm environment) 

•  Person is too far from the PIR switch, see detection diagram. 

•  Person is moving unusually slowly (perhaps when testing).

The load switches on when nobody is present: 

•  Heater causing infra-red variations in a cold small room or ceiling void  

  drafts, fans, or sealed doors causing air movement. 

    Reduce the sensitivity adjuster or consider using the CESF PIR 2D  

    double detection version. 

•  Please contact DANLERS for further technical support.