ELECTRICAL PRECAUTIONS 

Always use a properly grounded outlet. Do not immerse plug in water. DO NOT REACH INTO WATER TO 

RE­MOVE PLUG. TURN OFF CIRCUIT FIRST. A "drip loop" should be provided. The "drip loop" is a loop in the 

cord below the level of the receptacle or plug that prevents water from traveling along the cord. The 

National Electric Code requires that a ground fault circuit interrupter  (GFCI) be installed in the branch 

circuit supplying fountain or pond equipment. Your dealer can supply GFCI units. NEVER REMOVE 

GROUND PIN FROM PLUG.  WARNING; FOR YOUR PROTECTION  ALWAYS UNPLUG THE UNIT FROM ITS POWER 

SOURCE BEFORE INSTALLING OR SERVICING. SHOULD THE UNIT  APPEAR TO BE NOT WORKING DO NOT 

REACH, REMOVE OR DISASSEMBLE UNIT BEFORE YOU DISCONNECT POWER. 

CAUTION 

The pump is intended to pump water only. It cannot  be used to pump oils, solvents, or gasoline. Although 

the pump will continue  to run if  there is  no water,  after 30 minutes damage may occur if allowed to run 

dry. 

ZG140  Rev. B    03/18

1)

Disconnect power to pump

2)

Remove pump from water.

3)

Position pump with volute inlet facing upwards

4)

Pour PumpGuard into volute inlet until full.

5)

Allow to soak for 2 to 3 minutes.

6)

Thoroughly rinse with clean water.

7)

Place pump back into service.

PUMPGUARD

TM

 pump maintenance solution is available in three si

z

es: 

4

 o

z

---------

Impeller/Volute Treatment 

------------------

Item 

#

 03

9

05 

32 o

z

-------

Soak/Dunk 

&

 Impeller treatment

-----------

Item 

#

 03

9

0

7

12

8

 o

z

-----

Commercial Si

z

--------------------------------  

Item 

#

 03

9

0

9

 

CARE AND OPERATING INSTRUCTIONS FOR 

MAGNETIC DRIVE 24/36 AND PONDMASTER® 24/36 PUMPS 

ITEM# 02740, 02745, 02750, 02755, 40140, 40145

FEATURES 

The  pump is a  magnetically driven centrifugal  water pump. It has no seals to wear and contains no oil. 

The  pump can be used  submerged  or  inline.  lnline means connections  are made directly  to the pump 

inlet and  outlet ports,  which  have  1" NPT threads. All electrical components are encapsulated in epoxy 

with no seals to wear or break. The energy used is approximately  1 /2 of regular motor  driven pumps. The 

prefilter screen is  provided  for  use  in  situations  where deposits  in  the  water could clog or  damage  the 

pump. This helps give uninterrupted service. 

INLINE PIPING 

Centrifugal pumps cannot pull water from a lower level. In order to start, pump must be below water level 

and filled with water. Unless the air can escape from the outlet,  the pump will not start. Do not use glues 

or solvents to connect the pumps threaded fittings. Use Teflon pipe tape. The pump cover is not designed 

to support long pipe runs or correct pipe misalignment. 

SERVICE AND MAINTENANCE 

The  pump  cover  should  occasionally  be  removed  to  clean  and  inspect  the  impeller  assembly.  The 

impeller is the only serviceable item and can be pulled out of the body. Do not take the impeller apart. If 

it  is worn or broken the entire impeller assembly should be replaced. This  will  restore the pump to original 

capacity. Pumps taken out of service for an extended period with fluid inside run the risk of forming a crust 

which may prevent subsequent starting. Saltwater should be flushed out with fresh  water. Always check 

cord for sharp bends which can cause premature cracking. Do not use power cord to lift or move pump. 

Magnet impeller assembly must be routinely cleaned to remove accumulations of scale or calcium. This procedure 

should be done at least once every three months 

-

 or more often if the water conditions require it. Salt water and hard 

water environments require more frequent cleaning. 

Pondmaster

®

 PUMPGUARD

TM

 WATER PUMP MAINTENANCE SOLUTION (sold separately) will instantly loosen scale, lime, rust 

and other detritus from moving parts and impeller chamber.  Most build

-

up can be removed without disassembling the 

pump.