background image

 
 

      IPS-AM 

 

 

 

 

 

            ORDERCODE D6503 

 

 
 

Summary of Contents for IPS-AM

Page 1: ...IPS AM ORDERCODE D6503...

Page 2: ...d You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work ha...

Page 3: ...structions Operating Determinations Connecting to the mains Description Features Overview Front panel Overview Back panel Operation Connecting the device Linking more units Using the active up down sw...

Page 4: ...connect this system to a dimmer pack Do not switch the system on and off in short intervals as this would reduce the system s life Do not open the device and do not modify the device Do not open this...

Page 5: ...all components connected to the DSA have sufficient power ratings Otherwise distortion will be generated because the components are operated at their limits Avoid ground loops Always be sure to connec...

Page 6: ...90 SLAVE3 controls CH91 CH120 E g SLAVE 3 LED and CH12 LED light both up This indicates that alarm CH102 is active 3 Alarm Status Display Turn on the power switch alarm LEDs 1 30 light up green which...

Page 7: ...unit will recognize an alarm signal as either a logic 1 high or as a logic 0 low signal A logical 1 signal should range between 5V and 24V Input current draw is less than 3mA 14 Activate DOWN Switch T...

Page 8: ...25 pin sockets are used to output the alarm signals Pin 1 10 are live terminals indicated by LED 11 20 Pin 14 23 are com Pin 11 13 and pin 24 25 are not connected The alarm output sockets will be acti...

Page 9: ...WPT Check that all foam and plastic padding is removed Secure the equipment into a 19 rack Connect all cables Connecting the device Below an example of a possible setup NOTE Always turn off and discon...

Page 10: ...e linked only the OR GATE OUT of the HOST is valid Using The Active Up Active Down Dipswitches Using the active up active down DIP switches allows you to link up to 4 neighbor zones to an alarm channe...

Page 11: ...mple 2 We want to Link 3 alarms up and 4 alarms down to each incoming alarm The DIP switches should be set according the following diagram In case of alarm on channel 14 an alarm will also be sent to...

Page 12: ...oduct will not function whatsoever If this happens follow the directions below to do so 1 Unplug the unit from electric power source 2 Insert a screwdriver into the slot in the fuse cover Open the fus...

Page 13: ...ption Less then 18W Alarm Output Channel 30ch Input Logic Level 5 24V High Level Signal or 0V selectable Alarm Output Level 0V Short Link Up Down 4 Channel Extension Weight 6 73kg 14 84lb Dimension Lx...

Page 14: ...2007 DapAudio...