MACH 7 

Centrale di comando per cancelli ad ante 
Control panel for swing gates. 
Cuadro de maniobra para puertas de hojas  
Centrale de commande pour portails battants 

Summary of Contents for MACH 7

Page 1: ...6 78 36034 Malo Vi Italy tel 39 0445 602261 fax 39 0445 585035 www daspi it info daspi it MACH 7 Centrale di comando per cancelli ad ante Control panel for swing gates Cuadro de maniobra para puertas...

Page 2: ...IP SWITCH SW1 e SW2 deve sempre essere effettuata a centrale spenta non alimentata SW1 ON OFF 1 Funzionamento ad un solo motore usare uscita M1 Funzionamento a due motori 2 Spunto alla partenza disatt...

Page 3: ...ude motore M1 Contatto N C 12 14 Ingresso per fotocellule attive solo in chiusura Ferma e inverte Contatto N C 31 32 Uscita 230Vac per alimentazione del primario trasformatore 12 15 Ingresso pulsante...

Page 4: ...he entrance the gate will do as follow 1 with the residential system OFF will close 2 with the residential system ON will re open and will re close after 2 seconds if trimmer TCA is more then zero Fea...

Page 5: ...onic clutch is working properly and check whether leaves can be stopped by hands during their movement according to the actual rules Teach to professional people in charge of the automation s maintena...

Page 6: ...la el cierre autom tico de las hojas despu s del tiempo programado de 0 hasta 120 seg girando el trimmer TCA todo sobre el cierre autom tico se anula Accionando el mando de STOP durante el tiempo de c...

Page 7: ...fi et si n ont pas t prises toutes les pr cautions n cessaires pour viter de possibles accidents alimentation lectrique d branch e y compris d ventuelles batteries tampon Toute utilisation pas pr vue...

Page 8: ...ionner les moteurs et r gler le trimmer POWER de fa on que les vantaux du portail puissent tre arr t s tout moment en opposant une force non sup rieure quant indiqu par les normes en vigueur R glable...

Page 9: ...ur r duire au minimum tout risque Alimenter la centrale V rifier que tous les led de signalisation des contacts normalement ferm s N C soient allum s dans le cas contraire v rifier les contacts des di...