Summary of Contents for PowerScan PD9531-AR

Page 1: ...PowerScan PD9531 AR Industrial Corded Handheld Auto Range Area Imager Bar Code Reader Quick Reference Guide...

Page 2: ...u can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media...

Page 3: ...ce 4 Scancode Tables 7 Keyboard Interface 7 Country Mode 8 Caps Lock State 12 Numlock 13 Programming 14 Using Programming 2D Codes 14 Configure Other Settings 14 Resetting Product Defaults 14 Reading...

Page 4: ...ii PowerScan PD9531 AR NOTES...

Page 5: ...shall mean acquire under license End User is not entitled to receipt or use of the source code of any licensed Software 1 4 Portions of the Datalogic Product are protected by the relevant and applica...

Page 6: ...any and all claims actions suits or pro ceedings as well as any and all losses liabilities damages costs and expenses including reasonable attorney s fees arising out of or accruing from or related t...

Page 7: ...ion of the laws of the country in which End User obtained the license to govern interpret and enforce all of End User s and Datalogic s respective rights duties and obligations arising from or relatin...

Page 8: ...otherwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator will be the sole arbitrator provided that the arbi trator was validly an...

Page 9: ...ou simply aim the scanner and pull the trigger Since the PowerScan PD9531 AR is a powerful omni directional reader the orientation of the symbol is not important Decoding Thanks to powerful algorithms...

Page 10: ...he Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along the...

Page 11: ...be aimed over the code center to get the best reading performance By completely pressing the trigger the illumination area appears and the code scan ning starts Aiming Pointer Scan the following symb...

Page 12: ...on All models are multi interface and support RS 232 USB and Keyboard Wedge Information and programming options for each interface type are provided in this section For defaults and addi tional inform...

Page 13: ...terface Type Quick Reference Guide 5 RS 232 RS 232 standard interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard in...

Page 14: ...an PD9531 AR USB continued USB OEM can be used for OPOS UPOS JavaPOS USB OEM a Download the correct USB Com driver from www datalogic com USB Keyboard with standard key encoding USB KBD USB Keyboard w...

Page 15: ...trol character emulation for keyboard inter faces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard K...

Page 16: ...ed by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Co...

Page 17: ...nce Guide 9 COUNTRY MODE continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces liste...

Page 18: ...D9531 AR COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces list...

Page 19: ...uick Reference Guide 11 COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Cou...

Page 20: ...he format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected ENTER EXIT PROGRAMMING MODE Caps L...

Page 21: ...ption specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRA...

Page 22: ...e once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT code again to accept your changes which exits Programming Mode and returns the reader to normal operation Confi...

Page 23: ...isi tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at whic...

Page 24: ...scan on time 1 has elapsed Reading a label does not disable scanning Double Read Timeout1 pre vents undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan n...

Page 25: ...ating Modes Quick Reference Guide 17 Scan Mode ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always...

Page 26: ...ransmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a dif ferent Read Mode Pick Mode is automatically disabled Multiple Label Reading The re...

Page 27: ...Characteristics User Environment and Regulatory infor mation Item Description Physical Characteristics Dimensions Height 212 mm Length 110 mm Width 74 mm Weight without cable 400 gr without cable Elec...

Page 28: ...m reflectance Resolution Max resolution 1D 3 mils Max resolution 2D 4 mils Depth of Field Typical a Symbology Code 39 10 mils 15 160 cm 40 mils 50 1100 cm 55 mils 70 1150 cm 100 mils up to 2300 cm EAN...

Page 29: ...de RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Com posites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417 UPC A...

Page 30: ...eps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu rable via the feature Goo...

Page 31: ...label the soft ware shall turn the green spot on for the time specified by the configured value N A N A Image Cap ture When ready to capture image Blue light flashes 2 times when updating N A aExcept...

Page 32: ...bel Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A R...

Page 33: ...Exterior surfaces and scan windows exposed to spills smudges or debris require periodic cleaning to ensure best performance during scanning Use a soft dry cloth to clean the product If the product is...

Page 34: ...nship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period which...

Page 35: ...or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obliga tions under t...

Page 36: ...support through its website Log on to www datalogic com and click on the SUPPORT link which gives you access to Downloads by selecting your product model from the dropdown list in the Search by Produ...

Page 37: ...Support Through the Website Quick Reference Guide 29 NOTES...

Page 38: ...Support Through the Website 30 PowerScan PD9531 AR NOTES...

Page 39: ......

Page 40: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 68...