Summary of Contents for PWR-480W

Page 1: ......

Page 2: ...ed in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogi...

Page 3: ...ALLATION CHECKLIST 4 3 MECHANICAL INSTALLATION 5 3 1 Cabinet Mounting 5 3 2 Cable Insertion 6 3 2 1 Cable Entry Plate 6 3 2 2 Cable Compression Connector 7 4 ELECTRICAL CONNECTIONS 8 4 1 DC Voltage Te...

Page 4: ...his symbol alerts the user they are about to perform an action involving either a dangerous level of voltage or to warn against an action that could result in damage to devices or electrical shock It...

Page 5: ...ce Downloads Product Certifications link where you can search your specific product certification SUPPORT THROUGH THE WEBSITE Datalogic provides several services as well as technical support through i...

Page 6: ...ir Intake Filtered Cooling Fan Out AC Line Input Compression Connector Cable Entry Plate Thermal magnetic circuit breaker Monophase Switching Power Supply Low voltage thermal magnetic circuit breakers...

Page 7: ...the direct connection block is protected by the internal power supply features the current limiting block is protected by three Miniature circuit breakers MCB 4 A 1p C Char Two output power supply st...

Page 8: ...vided where overload power is supplied as explained in the examples below Example 1 Up to 120 power overload The overload is supplied for approximately 12 seconds and then is reduced Voltage and Curre...

Page 9: ...This procedure is repeated until the excessive current overload is resolved Figure 5 Overload Protection at 125 Example 3 150 power overload The overload is supplied for approximately 4 seconds and t...

Page 10: ...e cables through the Cable Entry Plate as described in par 4 4 Connect your devices to the PWR according to the information in par 4 2 SYSTEM WIRING AC INPUT 5 To comply with EN 60950 1 2007 par 1 7 2...

Page 11: ...nt the bracket to the cabinet 2 Mount the cabinet to the frame Figure 7 Mounting Brackets IMPORTANT The cabinet must be installed vertically in such a way that the upper key lock is no higher than 1 9...

Page 12: ...mets that can be inserted into the plate Follow these instructions to correctly insert the cables 1 Determine the number and size of the cables coming into and leaving the PWR 480W 2 Take one cable en...

Page 13: ...ion connector see Figure 2 item 4 is used for AC connection Pass the cable through the compression connector and make sure there is enough length to easily reach the AC Terminal Block see Figure 2 ite...

Page 14: ...s are pre installed on one end in the PWR 480W terminal block as shown in Figure 10 The other end of the F10 cable must be inserted in the left contact hole of the connector available in the DC3000 pa...

Page 15: ...sioners However the Dimensioner motors start up slowly so that there is no significant peak current draw See the Dimensioner manual for consumption data Two Head Dimensioning System Devices Use Device...

Page 16: ...PWR 480W INSTALLATION MANUAL 10 4 Figure 12 Connecting PWR 480W to Two Head Dimensioning System AC in Laptop PC for configuration 11 4 3 1 2 5 6 7 8 9 10 12 13...

Page 17: ...0 Head 2 Slave 7 24 Vdc Power from Terminal Block to DM3610 Power M12 5 pin CS A1 03 U 10 or AS I cable plus branch 8 DM3610 Slave I O M12 17 pin to CBX M12 8 pin CAB 3605 Encoder Tach 9 Encoder Tach...

Page 18: ...protection For primary wiring use a 3 conductor cable between 2 5 mm2 4 mm2 13 AWG 11 AWG for every conductor Choose the overall cable diameter and UL Listed conduits accordingly The AC input cable mu...

Page 19: ...an it with compressed air or replace it with new filter material The filter type material to use is Class G3 according to norm EN 779 3 Reinsert the clean filter and close the filter grill 6 2 COOLING...

Page 20: ...vercurrent 20 A 22 A up to 40 C ambient temp ENVIRONMENTAL FEATURES Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 25 to 70 C 13 to 158 F Humidity 5 95 non condensing Protection Class...

Page 21: ...LECTRICAL DIAGRAMS 15 A A ELECTRICAL DIAGRAMS PWR 480W ELECTRICAL DIAGRAM The PWR 480W components are electrically connected as displayed in the following diagram Figure 14 PWR 480W Electrical Diagram...

Page 22: ......