CODE SELECTION
EAN/UPC disable
AA0
EAN 8/EAN 13/UPC A/UPC E enable
AA1
AA5
AA8
without ADD ON
with ADD ON
with and without ADD ON
EAN 8/EAN 13 enable
AA3
AAK
AAL
AA6
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
UPC A/UPC E enable
AA4
AAM
AAN
AA7
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
EAN 8 enable
AAG0
AAG1
check digit transmission disable
check digit transmission enable
EAN 13 enable
AAH0
AAH1
check digit transmission disable
check digit transmission enable
UPC A enable
AAI0
AAI1
check digit transmission disable
check digit transmission enable
UPC E enable
AAJ0
AAJ1
check digit transmission disable
check digit transmission enable
Code 39 disable
AB0
Code 39 Standard enable
AB11
xxyy
AB12
xxyy
AB13
xxyy
no check digit control
check digit control and transmission
check digit control without transmission
Code 39Full ASCII enable
AB21
xxyy
AB22
xxyy
no check digit control
check digit control and transmission
Code 2/5 family disable
AC0
Interleaved 2/5 enable
AC1
1xxyy
AC1
2xxyy
AC1
3xxyy
no check digit control
check digit control and transmission
check digit control without transmission
Normal 2/5 5 bars enable
AC2
1xxyy
AC2
2xxyy
AC2
3xxyy
no check digit control
check digit control and transmission
check digit control without transmission
Industrial 2/5 (IATA) enable
AC3
1xxyy
AC3
2xxyy
AC3
3xxyy
no check digit control
check digit control and transmission
check digit control without transmission
Matrix 2/5 3 bars enable
AC4
1xxyy
AC4
2xxyy
AC4
3xxyy
no check digit control
check digit control and transmission
check digit control without transmission
Codabar family disable
AD0
Codabar standard enable
AD111
xxyy
AD112
xxyy
AD121
xxyy
AD122
xxyy
AD212
xxyy
no start/stop character equality control - nor transmission
no start/stop character equality control but transmission
start/stop character equality control but no transmission
start/stop character equality control and transmission
ABC Codabar no start/stop character equality control but transmission
Code 128 family disable
AI0
Code 128 enable
AI11
xxyy
control without transmission of check digit
EAN 128 enable
AI21
xxyy
control without transmission of check digit
Code Length
AILxxyy
Code 93 family disable
AK0
Code 93 enable
AK1
xxyy
control without transmission of check digit
PDF417 disable
AR0
PDF417 enable
AR1
Pharmacode disable
AQ0
Pharmacode enable
AQ1xxyy
AQ2xxyy
forward code tx direction
reverse code tx direction
Overflow ratio
AQAzz
xxyy
= ASCII numbers that define:
xx
= min. acceptable code length
yy
= max. acceptable code length
zz
= overflow ratio value
The minimum code length must always be less than or equal to the maximum.
For more detailed information on the TC1100 programmability and complete parameter list, please refer to the
TC1100 Reference Manual.
N2468
821000676 (Rev. H)
TC1100
CCD Scanner
Quick Reference Guide
The TC1100 is a linear CCD Scanner for OEM applications. It is available in two different versions:
Model Description
Order
Number
TC1100-1100
CCD scanner for linear codes
939501020
TC1100-1200
CCD scanner for linear and PDF417
939501030
Technical Specifications
Power supply
5 Vdc
±
5%
Consumption 1.5
W
Interfaces
RS232, WEDGE, PEN Emulation
Max Scans/sec
270
Max resolution
0,076mm (3mils)
Readable codes:
EAN/UPC, Code 39, 2/5 family, Codabar, Code 128, EAN 128, ISBT 128, Code 93,
pharmaceutical codes, Delta IBM, Code 16K, Code 49, (Telepen, MSI/Plessey, Pharmacode
only TC1100-1100), (Codablock-A, Codablock-F Std, Codablock-F EAN, PDF417 only
TC1100-1200)
Default Configuration
Power Save
270 scans/sec, sleep disabled, standby disabled
Reading Parameters
On-Line
Code Selection
Enabled codes
(Only TC1100-1200)
•
Interleaved 2 of 5: Check Digit transmitted, length: min 4, max 99
•
Code EAN8, EAN13, UPCA, UPCB: without ADD ON, Check Digit transmitted, no conversions
•
Code 39: length: min 1, max 99
•
Code 128: Check Digit not transmitted, length: min 1, max 99
•
PDF417
Data Format
Code ID disabled, Header = <STX>, Terminator = <CR> <LF>, no Field Adjustment, Code
length TX disabled, character replacement disabled, No Read Character = <CAN>
Decoding Parameters
Ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver
™
disabled, decoding safety = 1 read
Enabled interface
RS232, 9600, N, 8, 1, no handshaking, ACK/NAK disabled, RX timeout 100 ms, FIFO
enabled, inter-character delay disabled
Reading Diagrams
-160
-140
-120
-100
-80
-60
-40
-20
0
20
40
60
80
100
120
140
160
0
20
40
60
80
100 120
140 160 180 200 220
240 260
280 300
320
0.13 mm
(5 mils)
0.30 mm
(12 mils)
0.50 mm
(20 mils)
0.20 mm
(8 mils)
0.20 mm
mm
-90
-80
-70
-60
-50
-40
-30
-20
-
10
0
10
20
30
40
50
60
70
80
90
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150 160 170 180
0.17 mm
(6.6 mils)
0.38 mm
(15 mils)
0.25 mm
(10 mils)
mm
Reading Diagram TC1100-1100 (code 39)
Reading Diagram TC1100-1200 (PDF417)