www.smartlockdigital.com

1.

Enter “Zero” six times

DUAL CODE

2.

Enter your existing six (6) digit code once

Two combinations required to open

3.

Enter your NEW six (6) digit code two times

TI ME DELAY

4.

If a mistake is made wait thirty (30) seconds and repeat steps 1-3

Delay period 1-99 minutes

5.

test lock operation several times before closing the door

Open period 1-19 minutes

39E ComboGard Pro

4300M swingbolt/ 6040M squarebolt/ 6034 springbolt instructions

Operating Guide

_

Factory default code is open on ‘1’ (see keypad only setup instructions before operating lock)

Opening the Lock

1.

Enter valid six (6) digit combination. The lock will emit a double beep if

valid code has been entered.

2. Within 3.5 seconds of entering the valid code the lock can be opened-

either turn the keypad or handle (depending on how the lock has been
installed. Please ask your installer for further details)

3.

Pull door open.

INVALID CODE ENTRY

– Triple beep after six (6) digits are entered

VALID CODE ENTRY

- double beep after six (6) digits are entered

Opening the Lock with Time delay

(feature must be pre-enabled)

1.

Enter valid six (6) digit combination. Delay period starts. LED flashes
RED at one (1) second intervals

2.

At end of delay period open period starts. LED flashes RED at ½ second

intervals. During open period enter valid code to open

1.

If valid code entered during delay, delay restarts

2.

If invalid code entered during delay, delay aborts

3.

If invalid code entered during open period, open period continues

Dual Combination Operation

(feature must be pre-enabled)

1.

Second user must be added in  setup  stage  of  lock  and  dual  mode

turned on. Second user cannot then be disabled or removed.

2.

If time delay is active, one valid code will start the delay period. Both

codes must then be entered to open the lock during the open period

3.

To open, enter both codes, one after the other

Time Delay Override Operation

(feature must be pre-enabled)

1.

User 9 must be added in setup stage of lock and TDO mode turned

on, User 9 cannot then be disabled or removed

2.

Entry of override code during Delay period will open the lock

3.

Entry of override code at any time will immediately open the lock

Silent Signal Alarm

(feature must be pre-enabled, duress interface required)

1.

Enter code as normal but enter the last digit one number HIGHER or
LOWER

EXAMPLE: code = 123456. Duress code is 123455 or 123457
The lock will open without any indication duress has been sent.

Changing your code

Always perform operation with the door open
If lock is enabled for dual code each code must be changed
independently

STANDARD
FEATURES

WRONG TRY
PENALTY

Four (4) consecutive invalid codes initiates
five minute delay period.

LOW BATTERY WARNING

Repeated audio and visual signal (LED
flashing and repeated beeping) during
opening indicates battery low.

AUDIO AND VISUAL SIGNAL

Double signal (LED flashes and unit beeps)
indicates entry is valid or accepted.
Triple signal indicates invalid or not
accepted.

PROGRAMMABLE FEATURES

ACTIVE

MANAGER CODE

Add/remove second user
Enable/disable second user

USER CODE

Open lock
Change Code

TIME DELAY OVERRIDE

VALID CODE ENTRY

- double beep after valid six (6) digits are entered

INVALID CODE ENTRY

– Triple beep after six (6) digits are entered and

old code is still valid

SILENT SIGNAL ALARM

Duress signal if last number of code (s) is

entered using one number higher or one
number lower

DISABLE LOCK

Input signal disables opening of lock by

valid code

Smartlock Digital – a division of Davcor Pty Ltd ABN 95 003 562 598 PH +61-2 9612 4774 Fax +61-2 9612 5774 email sales@smartlockdigital.com