background image

INSTALLATION AND

 OPERATING INSTRUCTIONS

POWER ACE

®

 CR 100, 150, 200 & 300

POOL PUMP

P/N 48841-6 Supersedes P/N 48841-5

Please pass these instructions on to the owner of this equipment.

– 2 –

Your Davey Pool Pump

Congratulations on your purchase of a quality product from the Davey range

of Pool and Sp

a Equipment.  Y

ou are assured of many years of reliable and

efficient performance from your Davey Power 

Ace

®

 CR Pool Pump backed

by Davey’s three year guarantee.

Davey Power Ace

®

 CR Pool Pumps have been designed to circulate

swimming pool and spa water in conditions set out in the Australian

Standard for swimming pool water quality (AS 3633) or equivalent.  They

should not be used for any other purpose without first consulting your Davey

Dealer or Davey Products Pty Ltd.

Davey design and build its own electric motors especially for its pumps.  The

matched motor and “pumping end” are designed to provide the quietest

possible operation while delivering maximum water flow.

Davey’s tot

ally enclosed fan-cooled motor incorporates “autostart” overload

protection with a built-in automatic thermostat designed to protect the motor

from overheating.

Every Davey Pool Pump is thoroughly water tested against a number of flow,

pressure, voltage, current and mechanical performance parameters.

Davey’s advanced pump manufacturing technology provides reliable and

efficient pumping performance that last

s and lasts.

INSTALLA

TION INSTRUCTIONS

Location

The pump should be located as close to the water as practicable and

mounted on a firm base in a well drained position, high enough to prevent

any flooding.  It is the installer

’s

 / owner’s

 responsibility to locate the pump

such that the nameplate can be easily read and it can be readily accessed

for service.

Where pumps and/or associated accessories have been installed by

authorised Davey Dealers or installers, end users should seek advice from

the original dealer/installer before making any site changes.

Weather Protection

It is recommended that the pump is protected from the weather.  Enclosures

should be ventilated to prevent condensation built-up and allow a free flow of

air for the fan cooled motor.

– 3 –

Power Connection

Davey Power Ace

®

 CR Pool Pumps are suitable for connection to a nominal 240

volt 50Hz power supply and are equipped with a flex and 3 pin plug.  If a power

outlet is not available within 3 metres of the pump, a 3 pin power point in a safe,

dry place, may need to be provided by an electrician.  Extension cords are unsafe

around pools, and should be avoided.  If the supply cord of this product is

damaged it must be replaced with Davey Supply Cord Part No. 43233-2.

Pipe Connections

Suction Piping

A barrel union is provided for connecting to the piping from the pool.  

The pumps

are designed to accept 40mm PVC pipe of the ID of the barrel union or 50mm

fittings on the OD of the barrel union.  50mm PVC pipe is required on the suction

side of the PACR300.  25mm or 32mm flexible hose can be used with the

PACR100 with the use of appropriate adaptor/s.  

The use of any pipe smaller than

those specified above is not recommended.  Suction piping should be free from

all air leaks and any humps and hollows which could cause suction dif

ficulties.

Discharge Piping

A barrel union is supplied for connecting the piping to the filter

.  The pump

s are

designed to accept 40mm PVC pipe on the ID of the barrel union or 50mm fittings

on the OD of the barrel union.  25mm or 32mm flexible hose can be used with the

PACR100 with the use of appropriate adaptor/s.  

The discharge piping from the

pump outlet should be connected to the inlet connection on the swimming pool

filter (usually at the filter control valve).

The installation of this product should be carried out by a person
knowledgeable in swimming pool plumbing requirements following the
Installation Instructions provided in this manual.

DAVEY PRODUCT GUARANTEE FOR AUSTRALIA & NEW ZEALAND

This Davey product is guaranteed to be free of material or manufacturing defects at the time

of original purchase.  Should any part fail as a result of such defects within three years of

original purchase, the product will be repaired free of charge.

TERMS AND CONDITIONS

1. This guarantee applies to all states and territories of Australia and New Zealand only and is

subject to the provisions of the Trade Practices Act (Aust.), the Goods and Consumer

Protection Legislation of the various Australian states and the Consumers Guarantee Act

1993 (NZ) as applicable.

2. The guarantee period commences on the date of original purchase of the equipment.

Evidence of this date of original purchase must be provided when claiming repairs under

guarantee.  It is recommended you retain all receipts in a safe place.

3. This guarantee covers parts and workshop labour only.  Goods should be forwarded, with

proof of date of original purchase, to an Authorised Davey Service Centre freight paid.  Any

travel and removal/reinstalling charges for goods repaired infield will be to the owners

account.  Guarantee may be denied on goods not readily accessible for service personnel

or mounted on exterior walls above single storey level.

4. This guarantee is subject to due compliance by the original purchaser with all directions

and conditions set out in the Installation and Operating Instructions.  Failure to comply

with these instructions, damage or breakdown caused by fair wear and tear, negligence,

misuse, incorrect installation, chemical or additives in the water, inadequate protection

against freezing, rain or other adverse weather conditions, corrosive or abrasive water,

lightning or high voltage spikes or through unauthorised persons attempting repairs are

not covered under guarantee.  The product must only be connected to the voltage shown

on the nameplate.

5. Without limiting the original purchaser’s entitlements under the Trade Practices Act (Aust.),

the Goods & Consumer Protection Legislation of the various Australian states, or the

Consumers Guarantee Act 1993 (NZ), Davey shall not be liable for any loss of profits or any

consequential, indirect or special loss, damage or injury of any kind whatsoever arising

directly or indirectly from the product or any defect.

6. Where the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of

the various Australian states and the Consumers Guarantee Act 1993 (NZ) does not apply,

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss,

damage or injury of any kind whatsoever suffered by the purchaser arising directly or

indirectly from the product or any defect and the purchaser shall indemnify Davey against

any claim by any other person whatsoever in respect of any such loss, damage or injury.

7. Nothing in this guarantee is intended to have the effect of contracting out of the provisions

of the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the

various Australian states and Consumers Guarantee Act 1993 (NZ) except to the extent

permitted by the various Acts, and this guarantee is to be modified to the extent necessary

to give effect to that intention.

8. Davey may be collecting personal information from you in order to provide you with a

service. Davey Pumps Pty Ltd promises only to use this information in accordance with the

Provisions of the Privacy Act 1988 (Cth) and the Privacy Policy of Davey Pumps Pty Ltd

which is available at www.davey.com.au.

®

Daveyand Power Ace are registered trademarks of Davey Products Pty Ltd.

©

Davey Products Pty Ltd 2000

In the interests of safety

, we advise that all brands and types of pool

pumps must be installed in accordance with AS3000 wiring rules or

equivalent.  Davey Power Ace

®

 CR Pool Pumps are supplied with a fixing

point to enable easy earthing / equipotential bonding when required.

Barrel unions need to be hand tightened only.  No sealant, glues or

silicones are needed.

If the pump and filter are located below pool water level, it is necessary

to fit isolating valves in the pipe between the pump and the skimmer

box and in the return pipe from the filter to the pool.

The fittings on this product are constructed of ABS.  Some PVC jointing

compounds are incompatible with ABS.  Check compound suitability

before use.

NOTE:

Power Ace

®

 CR Pool Pumps are fitted with an internal check valve to

prevent the reverse flow of water through the pump.

Davey Products recommends that all installations are fitted with earth

leakage or residual current protection devices.

Warning!  Ensure that an electrical isolation switch is located with easy

access so that the pump can be switched off in an emergency.

Davey Products Pty Ltd

Member of the GUD Holdings Ltd Group

ABN 18 066 327 517

Head Office and Manufacturing

6 Lakeview Drive,

Scoresby, Australia 3179

Ph:

+61 3 9730 9222

Fax:

+61 3 9753 4100

Website: www.davey.com.au

Customer Service Centre

Ph:

1300 367 866

Fax:

1300 369 119

E-mail: sales@davey.com.au

Interstate Offices

Sydney – Brisbane – Adelaide

Perth - Townsville

International

6 Lakeview Drive,

Scoresby, Australia 3179

Ph:

+61 3 9730 9121

Fax:

+61 3 9753 4248

E-mail: export@davey.com.au

Germany

Kantstrasse 47,

04275 Leipzig

Ph:

+49 341 301 0412

Fax:

+49 341 301 0413

E-mail: akrenz@daveyeurope.com

New Zealand

220A Bush Road,

North Harbour, Auckland 1330

Ph:

+64 9 914 3680

Fax:

+64 9 914 3685

Website: www.daveynz.co.nz

E-mail: sales@daveynz.co.nz

U.S.A.

1005 N. Commons Drive

Aurora, Illinois 60504

Ph:

+1 630 898 6976

Fax:

+1 630 851 7744

Website: www.daveyusa.com

E-mail: sales@daveyusa.com

Reviews: