Product number 6810 and 6805
USER
MANUAL
Davis Instruments, 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. • 510-732-9229 • www.davisinstruments.com
R
Ethernet
Gateway
and
Node
Page 1: ...Product number 6810 and 6805 USER MANUAL Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisinstruments com R Ethernet Gateway and Node...
Page 2: ...er s authority to operate this equipment FCC ID IR2DWW6805 IC 3788A 6805 Contains FCCID 2AC7Z ESPWROOM02 IC 21098 ESPWROOM02 The antenna used for this transmitter must be installed to provide a separa...
Page 3: ...way This manual will show you how to set up both the EnviroMonitor Gateway and Nodes If you are just installing a Node and have already installed the Gateway you can skip to page 9 Set Up Nodes and Se...
Page 4: ...r will block signals If transmitting under a canopy or in an orchard range will be reduced Mount the devices as high above the ground or the highest crop height as possible The higher they are mounted...
Page 5: ...lation to get an idea of where the Gateway and Nodes should go SAMPLE FARM Vegetables Almonds East Almonds West Peppers H w y 1 0 Davis Rd Strawberries G N N N N N N N N N N N N Diablo Creek Gateway N...
Page 6: ...either two or more other Nodes or the Gateway and another Node A Node can even be installed simply to transmit data from more distant Nodes to the Gateway without any sensors installed in it By planni...
Page 7: ...ntents of Gateway Ethernet Gateway Requirements Tools Wi Fi or router Ethernet internet connection Wi Fi password Smartphone 4 AA batteries not included Ethernet Gateway AC Adapter Blue LED Capacitive...
Page 8: ...or app will guide you through creating an account on WeatherLink com adding the Gateway adding Nodes to the Gateway and adding sensors to the Node EnviroMonitor App EnviroMonitor App Guides you throug...
Page 9: ...n the cable Note The Gateway is powered by AC power with battery backup AC power is required it cannot be set up or run on batteries alone It is highly recommended that you install batteries to preven...
Page 10: ...a message appears that an upgrade has been detected select Upgrade Upgrading can take several minutes Tip The blue LED flashes to show that the Gateway s BLE is on If it is not flashing press the rece...
Page 11: ...tery in hardware kit Solar Panel Cable Mesh status LED Bluetooth status LED Solar Panel Jack Sensor Ports Mesh Antenna Lithium Battery Battery Compartment Door Door Tabs 1 4 Lock Washers 1 4 Hex Nuts...
Page 12: ...sure the EnviroMonitor app has been installed on the smartphone you will be using to install the Node It will guide you through adding Nodes to the Gateway that has already been installed Power Up the...
Page 13: ...mission Using the app you will be see this Node s serial number appear on the list for the Gateway You will know the Node has found its mesh parent a Gateway or another Node when you see the Bluetooth...
Page 14: ...an RJ plug on its cable use the Davis RJ Adapter product number 6860 Or you can remove the plug and strip the wires Try not to strip the covering back so far that the bare wires can touch each other w...
Page 15: ...Hemisphere or north in the Southern Hemisphere Tip Mounting the Node may be easier if done by two people Mounting On a Fence Post or Pole Mount the Node onto a fence post or a pole with an outside di...
Page 16: ...d manage your data You can also use view and manage your data on your smartphone with the Mobilize app Find the app by searching for Davis Mobilize in the iOS App Store or Google Play Store You can al...
Page 17: ...g connection Make sure the green sensor adapters in the Node are aligned properly and not offset Make sure the screws on the sensor adapters are very tight Make sure none of the sensor cables are pinc...
Page 18: ...Radio LED The radio LED has timed out to save power Close then open the door to activate the radio LED Radio LED is solid amber for 3 seconds when powering up The Node is powering up Radio LED is blin...
Page 19: ...ntact Davis Technical Support We ll be glad to help Online www davisinstruments com See the Weather Support section for copies of user manuals product specifications application notes software updates...
Page 20: ...Power 2402 2480 MHz less than 1mW Certifications FCC CE IC Sensor Data internal sensors Barometric Pressure Resolution and Units 0 01 Hg 0 1 mm 0 1 hPa 0 1mb user selectable Range 16 00 to 32 50 Hg 4...