Page 1: ...USER GUIDE FOR ICONNECTOR 3G INTEGRATED WIRELESS CO ORDINATOR STHC ISG02DB WS433 CL 04 USER GUIDE FOR ICONNECTOR 3G STHC B ISG02DB 03 Smart IoT Gateway iConnector ...

Page 2: ... diagnostics as well as remote monitoring and control via any IIoT platform It is able to configure the parameters for all end nodes in the network By the Sub Ghz technology from Texas Instruments it is easy to establish multiple networks in same area without interference or channel conflict One co ordinator can handle maximum of 40 end nodes in its network LOS transmission distance up to 6000m The ...

Page 3: ...imension H106 x W73x D42 mm excluded antenna Net weight 190 grams Box dimension W160 x D150 x H100 mm Gross weight 300g After the power supply will have 5 minutes to add nodes value enb_auto_add_sensors 1 in 5 minutes then 0 push button function and hall sensor are only available in the first 5 minutes Push Button or Hall sensor for the first 5 minutes when power is available Press and hold the pu...

Page 4: ... the power the iConnector wait a few minute and try again Node id added in this way will be written to thesmallest node_id_n address which is 0 Set Rssi_threshold see RF MODE CONFIG in the Modbus Memmap of WS433 CL FW_V1 9 default 25 The case if Co ordinator is on high position and need to add node sensor We set the sensor as close as possible and set the Rssi_threshold to 80 90 or 100 to increase...

Page 5: ...s displays disconnected to connected It means the WS433 CL 04 is being connected with computer Next we need to import the configuration file for WS433 CL 04 by importing the csv file Go to MENU FILE Import New select the file with name Template_WR433_V1 6 csv This file is attached in the zip file WS433 CL H16 png Step 2 Check information of sensor after adding S N of each sensor iConnector 3G uses...

Page 6: ...o LOS condition However the two modules still communicate each other but the distance will be reduced significantly Therefore to maximize the transmission distance please pay attention to the following conditions DO NOT install the wireless module inside a completemetallic box or housing The signal can not pass through metallic wall This wireless module would be installed a semi metallic box becau...

Page 7: ...F frequency data rate of iConnector and the node 3 Read modbus normal health values but read the data of the node all are 0 The modbus 4 command only supports FW 1 9 old FWs can t read command 4 Check the FW of WS433 CL in iConnector if it is older than 1 9 then use command 3 to read data and other registers 4 The node s data has no data of prm1 and prm2 The sensor attached to the node is loose Fo...

Page 8: ... 4143 2288 Mobile 012 376 7181 Fax 603 4143 3388 Distributor in Australia and New Zealand temploggerlogo png Templogger Pty Ltd Tel 1800 LOGGER Email contact templogger net Manufacturer logo jpg Dai Viet Controls Instrumentation Company Ltd No 11 Street 2G Nam Hung Vuong Res An Lac Ward Binh Tan Dist Ho Chi Minh City Vietnam Tel 84 28 6268 2523 4 ext 122 Email info daviteq com www daviteq com ...

Page 9: ... Primary battery 3 6V suitable for applications where no grid power like Water pipeline water network In addition STHC B is also powered by external power supply 7 48VDC or Solar panel system STHC B has built in 1 Pulse input to read the Pulse from flow meter and 01 Digital input can connect to Pressure sensor Level Temperature Humidity Data will be sent back to server for data logging data analyt...

Page 10: ...ing 9 digits Digital Sensor Input 1 x Digital sensor input for DULP sensor type Digital Ultra Low Power M12 connector IP67 Battery Supply 1 x D size battery holder 3 6VDC External Power Supply 7 48VDC avg 200mA peak 1 5A Back up battery Lithium Super Capacitor to alert shortage of power supply On board logging 2MB Flash SIM slot 01 x micro SIM Operating Temperature 20 85 degC refer temperature wor...

Page 11: ... save energy If we supply external power through M12 connector iConnector will run realtime After reading the sensor value the raw data isX it can be scaled to any technical value by the following formula Y aX b Where X the raw value from sensor Y the calculated value for parameter 1 s value or parameter 2 s value a constant b constant So if there is no user setting fora and b Y X The Y value will...

Page 12: ...the formula R W 914 392 4 float I2C prm1_b The b constants after calculation according to the formula R W 918 396 4 float I2C prm1_hi_cut Cut the upper threshold of I2C e g If prm1_scaled_value prm1_hi_cut then prm1_scaled_value prm1_hi_cut R W 922 39A 4 float I2C prm1_lo_cut Cut the lower threshold of I2C e g If prm1_scaled_value prm1_lo_cut then prm1_scaled_value 0 R W 9398 24B6 1 uint8 I2C sens...

Page 13: ...Step 1 Open the cover of the iConnector Step 2 Connect the Configuration Cable to the UART Port in iConnector ...

Page 14: ...Step 3 Power the iConnector via M12 male connector on iConnector Step 4 Connect the USB port of the Configuration Cable to the Computer ...

Page 15: ...1PxD Unzip file and run file application iconnector_config Choose COM Port the Port which is USB cable plugged in Set the BaudRate 9600 Parity none Click Connect untill the Status displays disconnected to connected It means the iConnector is being connected with computer Configuration parameters 5 3 2 Configuration tool ...

Page 16: ...splayed in theValue column shows the corresponding data the configuration is completed iConnector 3G uses micro SIM and needs to be configured to use the data network 1 Open iConnector cover and install the SIM card 2 Based on the information of the mobile carrier that provides the SIM card we configure data such as APN username password on the 2G 3G tab 5 4 SIM configuration ...

Page 17: ... e g 200 ms I2C num_of_sample The number of ADC samples taken in a reading of sensor data the more samples the longer the sensor reading time For example 8 samples with each sample have a reading time of 10ms then the total sampling time is 80ms I2C prm1_a The a constants after calculation according to the formula 5 5 Configure sensor parameters on the iConnector 5 5 1 Configure I2C_Sensor tab ...

Page 18: ...or value read from I2C When iConnector only works with D type battery 3G network will turn off only when the 3G data sending cycle is turned on to send data after sending it will turn off Not sending a ping leads to iConnector not running realtime unable to sync from the server Unable to configure from iConfig software When iConnector is connected to 7 48VDC power source 3G network is always on ru...

Page 19: ...Install the sensor as shown below 6 2 IO Wiring Sensor installation ...

Page 20: ...Step 1 Open the back cover of the sensor Step 2 Wiring to sensors ...

Page 21: ...Step 3 Connect Sensor to Input 4 20mA port of iConnector via M12 connector ...

Page 22: ...ilerun daviteq com wl id lT9lfZuEQUQksWLhFgSoQrs28sEGY0Kt Connect 7 48VDC power supply to iConnector via M12 Male connector Use M12 female connection cable to connect to iConnector 6 3 Power Supply Battery installation 6 3 1 Power Supply of iConnector ...

Page 23: ...Steps for battery installation Step 1 Using Flat Tip Screwdrivers to open the cover Step 2 Carefully pull out the top plastic housing 6 3 2 Battery installation ...

Page 24: ...Step 3 Insert the type D battery 3 6VDC please take note the poles of battery Step 4 Insert the top plastic housing and locking by Flat Tip Screwdrivers No Phenomena Reason Solutions 7 Troubleshooting ...

Page 25: ...he sever No power supply The network information of the SIM card data is incorrect No SIM card inserted Check the power supply Check that the battery is empty or not installed correctly Check the sim card configuration section 3 The battery drains quickly Turn On Off tab configuration is incorrect Check the configuration of the Turn On Off tab ...