Page 1: ...1...
Page 2: ...sure that necessary conditions are provided for safety operation of the device Energy must be provided to device with suitable cable section determined inside this manual Residual Current Device and g...
Page 3: ...f the device OFF position Close taps both heating and hot water network Discharge heating installation and boiler cycle for preventing freezing Device cannot be used by children or disabled people wit...
Page 4: ...ositioned properly For sensing room thermostad ambient temperature correctly that it placed it should be positioned far and proper height from window object or heat source Ventilation of heated enviro...
Page 5: ...CONFIGURATION OF DEVICE Capacity 10 24 KW 30 48 KW 72 96 KW a 700 700 900 b 400 450 600 c 220 320 290 d 58 83 100 e 122 147 f 277 302 g 342 367 500 h 65 75 100 i 200 225 300 j 150 175 200 k 100 100 2...
Page 6: ...6...
Page 7: ...ical Heating and Hot Water UKDAX 6EDM 6 700 400 220 23 5 7 3 4 UKDAX 10EDM 10 700 400 220 23 5 7 5 8 UKDAX 12EDM 12 700 400 220 23 5 7 6 9 UKDAX 16EDM 16 700 400 220 25 0 7 9 2 UKDAX 18EDM 18 700 400...
Page 8: ...Specificitions Radiator Tap Water Min Operation Pressure bar 1 0 5 Max Operation Pressure bar 3 10 Min Setting Temperature oC 10 35 Max Setting Temperature oC 80 55 Connections inch ETP Model Connect...
Page 9: ...device Installation must not be made on the cooker or similar cooking devices Do not leave combustion products inside device installed room Heating sensitive walls for example wooden walls must be pro...
Page 10: ...rying the weight of the device 5 2 Wall Installation of Device Drill installation holes to chosen place according to conditions stated above and fasten fixing plugs Control durability of device by scr...
Page 11: ...valve if there is decrease 5 2 1 2 Filling Heating System for ETT ve ETM Models For UKDAX xxETT and UKDAX xxETM models this process is made with filling valve which will install to heating system Beca...
Page 12: ...it can be decrease at heating system water pressure Make sure that heating system water pressure is between 1 1 5 bar If decreases complete it by opening filling tap After filling radiator installatio...
Page 13: ...be made for device authorized person Grounding must be controlled if it is operative or not by authorized personnel in determined period Fuse must be located near the device there must be cable after...
Page 14: ...45 5 1 50 3 6 UKDAX 12EDM 12 1 54 6 1 63 3 10 UKDAX 16EDM 16 1 72 8 1 80 3 16 UKDAX 18EDM 18 1 81 9 1 100 3 16 Model Power kW Drawn Current A Fuse and Residual Current Device A Section 3 400 V 50 Hz E...
Page 15: ...or Days Of Week Time programming Can be made 3 pcs time programming Hour Capacity Indicator Ready to operation indicator Hot Water Heating Indicator Radiator Heating Indicator Over Temperature Indicat...
Page 16: ...sible from damages and accidents which can be occur because of wrong connection Follow following points for operation of device Make sure that device water and radiator valves are open Make sure that...
Page 17: ...ode of device is set as hot water before OFF positon shower is seen and device passes to standby mode If hot water tap turn on device starts to heat tap water When operation mode of device is set as t...
Page 18: ...iator heating is seen with heating word after pump operates about 1 min device starts to radiator heating is seen Warning beep is heard after process of pressing knob For long time pressing knobs fore...
Page 19: ...19 6 4 Operation Parameter Setting 6 4 1 Day and Hour Setting Switch of the device Hold button 5 6 seconds Days start to blink...
Page 20: ...20 Days are set by pressing with one second intervals to or buttons Press button hour blinks By pressing or one second interval hour is set between 0 and 23...
Page 21: ...21 Press button minute blinks By pressing or button one second interval min set between 0 and 60 By pressing button or if not pressing any button for a 10 sec exit from setting menu by saving settings...
Page 22: ...ng radiator heating it is needed to take operation mode to radiator heating At the end of the process device must be taken to previous operation mode Check 6 4 8 After 2 sec later setting completed de...
Page 23: ...ater heating it is posiible to change water temperature at standby mode While radiator heating is operating for setting temperature of water it is needed to change operation mode of the device as hot...
Page 24: ...en Heating Exit and Heating return of device can be set While the device is in normal operation mode Enter setting menu by pressing 2 3 seconds Press the button one second interval until is seen Tempe...
Page 25: ...n of device is making 6 4 6 Heating Mode Setting Device can be set according to floor heating low temperature or radiator heating system In this way overheating is prevented especially for floor heati...
Page 26: ...ce max 55C by changing into heating mode to ground heating mode While symbol is seen at radiator mode it is not seen at floor heating mode While device is operating regulary Enter the setting menu by...
Page 27: ...for floor heating mode 1 is chosen for radiator heating For floor heating systems because of heating mode is set from inside device by authorized service in this menu 0 set can not be changed Exit se...
Page 28: ...full capacity Forexample if the device is 24kw P1 8 KW P2 16kw P3 24 KW Enter setting menu by pressing button 2 3 seconds Press one second interval until is seen Definitely temperature must not set o...
Page 29: ...29 With or buttons device capacity can be set as P1 P2 or P3 Indicator lights change according to chosen capacity...
Page 30: ...nly heats the tap water This mode can be also named as Heater mode or Summer mode Radiator and Tap Water Heating Mode Device makes both radiator heating and tap water heating Priority is for tap water...
Page 31: ...e second interval until heating and or shower blink With or button preferred mode is chosen If heating is chosen device only operates for radiator heating If shower is chosen device operates for only...
Page 32: ...rams the start and end times of the program the operating temperature of the device and the T temperature difference can be adjusted If the programming has been made and activated the device will not...
Page 33: ...33 Press button 2 3 second and enter setting menu Press button one second interval until Timing Time Phase is seen Timing program blink By pressing or buttons timing program is chosen between 1 and 7...
Page 34: ...34 Press button With or buttons timing program is ON position If it stays at OFF position can not be entered to timing program By pressing button week day days are chosen...
Page 35: ...35 With or buttons intended week day or days can be chosen Week days are group as in the following All days can be chosen SUN MON TUES WED THUR FR SAT Weekends SUN SAT Weekdays MON TUES WED THUR FRI...
Page 36: ...36 Days can be chosen one by one Press button program start hour blinks With or buttons program start hour is determined...
Page 37: ...37 Press button Program start minute blink With or buttons program start minute is determined Press button Program finish hour blink...
Page 38: ...38 With or buttons program finish hour is determined Press button Program finish min blink With or buttons program finish minute is determined...
Page 39: ...39 Press button Temperature indicator blink Operation range of intendent program is chosen with or buttons Press button symbol and exit return temperature difference blink...
Page 40: ...40 Intendent T exit return temperature difference is chosen with or buttons Press Other intetendent time program is chosen and repeat stating from 3rd step...
Page 41: ...as much as you want Because of unadjusted programs remain OFF position they will not be active After programming is finished when it is pressed to button or not pressing any button with 10 seconds ca...
Page 42: ...and heating will operate for a while During anti frost time is seen at LCD Display Anti Blockade Function Pump and 3 way valve inside the device start to operate for a short time once every 18 hrs 6...
Page 43: ...43 7 ELECTRIC DIAGRAM...
Page 44: ...efect of related materials and production When you meet with problem while using please contact with our after sales service department Repairing and maintenance of the device by unauthorizedperson wi...
Page 45: ...temperature is over 85 oC Device will start to operate a few min later S cakl k 85 oC nin alt na d t nde Warning of limit thermostad is in circuit al maya ba layacakt r When the temperature is below 8...
Page 46: ...46...