background image

© 1994, 1997 Directed Electronics, Inc. 97G432.597

Model 5000

Owner's Guide

This device complies with part 15 of FCC rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful  interference,
and (2) This device must accept any interference received,  including inter-
ference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this
device.

Summary of Contents for 5000

Page 1: ... the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including inter ference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device ...

Page 2: ...3 Arming while driving 4 Disarming 4 Disarming Without A Transmitter 5 Silent Modetm 5 Panic Mode 5 Valet Mode 6 Remote Valet 6 Nuisance Prevention Circuitry 6 Diagnostics 7 Arming Diagnostics 7 Disarming Diagnostics 8 Table of Zones 8 Code Hopping Explained 9 Programming Options 9 Glossary Of Terms 11 Security Convenience Expansions 12 Quick Reference Card Removable 13 ...

Page 3: ... warranty All dealers are provided with a preprinted dealer certificate to verify that they are authorized The system requires no specific maintenance Your remote control is powered by a miniature 12V battery type GP23A that will last about a year under normal use When the battery weakens operating range will be reduced and the LED on the remote will light dim Your Warranty card must be returned a...

Page 4: ... Mode and Remote Valet work by pressing Button II for less than one second Trunk release requires you to press Button II for 1 5 seconds Button III for options Usually controlled by pressing Buttons I and II at the same time These assignments can be changed if needed such as for two car operation from one remote 2 1994 1997 Directed Electronics Inc 97G432 597 Button I Button II Button III ...

Page 5: ...s LED will flash twice as fast as it does when the system is armed NOTE If any protected entry point such as a door or a switch protected trunk or hood is open the system will not passively arm unless forced passive arming is programmed on See Programming Options section Additionally each time a sensor is triggered during the arming countdown the 30 second countdown starts over When armed your veh...

Page 6: ...ot disarm the system it will trigger when any door is opened to exit the vehicle Disarming To turn off or disarm the system press Button I again You will hear two chirps and the parking lights will flash twice If power locks are con trolled by the system the doors will unlock If the siren chirps either four or five times when disarming see Diagnostics section This is called Tamper Alert Your syste...

Page 7: ...To temporarily turn off the arm or disarm chirps use Silent ModeTM Simply press Button II briefly before arming or disarming and the con firmation chirp s will be eliminated for that one operation only If you want the arm disarm chirps turned off permanently your dealer can do this for you NOTE The Warn Away response to lighter impacts is bypassed if the system is armed using Silent Mode This ensu...

Page 8: ...s LED will light steady if you have entered Valet Mode and it will go out if you exited Valet Mode Nuisance Prevention Circuitry Your system has DEI s Nuisance Prevention Circuitry NPC It pre vents annoying repetitive trigger sequences due to faulty door pin switches or environmental conditions such as thunder jackhammers airport noise etc Here s how it works Let s say the alarm triggers three tim...

Page 9: ...hree seconds later it will monitor that input normal ly For example if your car has interior light exit delay and you arm the system before the interior light goes out you may get Bypass Notification Once the light goes out however the doors are monitored normally 7 1994 1997 Directed Electronics Inc 97G432 597 Doors are covered by NPC differently If the alarm is triggered by an open door for thre...

Page 10: ...each time it is disarmed until the next time the ignition key is turned on Table of Zones The zone number is the number of LED flashes used by the system to identify that input The standard input assignments are listed below along with spaces to write in any optional sensors or switches you have had installed 8 1994 1997 Directed Electronics Inc 97G432 597 If the Warn Away signal is triggered the ...

Page 11: ...alarm will automatically re synch and respond to the transmitters normally Programming Options Programming options control what your system does during normal operation and require little or no additional parts However some may require additional installation labor The factory settings are in bold Active arming only with the transmitter or passive arming auto matic arming 30 seconds after the last...

Page 12: ...e FailSafe starter kill relay has been installed Forced passive arming on or off If your system is programmed to passively arm and this feature has been programmed on the sys tem will passively arm after one hour even if a protected entry has been left open If a door has accidentally been left ajar when leav ing the vehicle forced passive arming ensures that the system will arm in one hour NOTE Wh...

Page 13: ...Double Guard Shock Sensor This sensor is contained within the control unit and designed to pick up impacts to the vehicle or glass Siren Noise generating device usually installed in the engine compartment of the vehicle It is responsible for generating the chirps you hear as well as the six tones you hear while the alarm is triggered Transmitter Hand held remote control which operates the various ...

Page 14: ...termine if the glass has been struck Power Trunk Release The Button 2 output of the system can operate a factory power release for the vehicle s trunk or hatch An optional relay may be required If the factory release is not power activated the DEI s 522T trunk release solenoid can often be added Power Locks This system offers lock outputs that can control some manufacturers power door lock systems...

Page 15: ... The sys tem should now disarm If it does not you may have waited too long so turn the ignition off and on and try again Silent ModeTM Press Button II briefly before arming or disarming and the confirmation chirp s will be eliminated for that one operation only Panic Mode Press Button I for 1 5 seconds and you will enter Panic Mode The siren will sound and the parking lights will flash for 30 seco...

Page 16: ... 1994 1997 Directed Electronics Inc 97G432 597 ...

Reviews: