background image

13

INTRODUCTION

Thank you for choosing a De’Longhi product. Please take a few 
moments to read the instructions to avoid risks or damage to the 
appliance. 

DESCRIPTION

Description of the appliance (see page 

2

 - A)

 

A1

   air outlet flap

A2

 control panel

A3

 handles

A4

 castors

A5

 BioSilver filter

A6

 air intake grille  

A7

 air exhaust hose housing

A8

 air intake grille

A9

 power cable

A10

 drainage hose with cap

A11

 CST remote control compartment

Descrizione of the accessories (see page 

2

 - B)

 

B1

 wall flange with cap

B2

 air exhaust hose

B3

 hose adaptor

B4

   adapter for window bracket

B5

 window bracket with wing nut

B6

 adapter for wall mounting/window outlet

B7

 window outlet

B8

 CST (Cool Surround Tecnology) remote control 

B9

 window bracket cap

ELECTRICAL CONNECTION

Before plugging into the mains, check the following:
•  the mains voltage is the same as that indicated on the plate 

on the back of the appliance;

•  the socket and electrical line are sized to support the load 

required;

the socket is the proper type for the plug, otherwise, re-
place the socket;

•  the socket is connected to an efficient earthing system.

The manufacturer is not responsible in the event of non-
compliance with these injury prevention standards.

• 

The power cable must only be replaced by special-

ised technicians.

USE

The instructions below will enable you to prepare your air con-
ditioner for operation as efficiently as possible. Before use, make 
sure the air intake and outlet grilles are unobstructed.

Please note: 

This appliance is provided with an auto-evapora-

tion feature for condensate removal during cooling and dehu-
midifing modes.

AIR CONDITIONING WITHOUT INSTALLATION

CASEMENT WINDOW

If you have a casement window proceed as follows:
•  Fit the air exhaust hose (B2) in the relevant housing located 

on the rear side of the appliance (fig. 1).

•  Screw the window outlet

 

(B7) and place outside the win-

dow to exhaust the hot air (fig. 2).

DOUBLE-HUNG WINDOW

If you have a double-hung window proceed as follows:

Insert and lock the adapter for window bracket (B4) into
the slot of the window bracket (B5) (fig.3)

 • Place the window bracket in the window sill, and extend

the bracket fully within the window frame (fig. 4). 

•  Fix the bracket by the wing nut (fig. 5) (Should the window 

bracket be too large for the window the plastic can be cut 
with a saw by a qualified professional).

•  Insert the air exhaust hose (B2) into the accessory for win-

dow bracket (B4) (fig. 6 ) and rotate it as shown in fig. 3.

•  In order to facilitate the fitting of the air exhaust hose (B2) 

in the relevant housing located on the rear side of the appli-
ance, position the hose adapter ‘s tabs  (B3) in a horizontal 
axis as shown in fig. 7  and  proceed as shown in fig.1.

SLIDING WINDOWS

•  Thanks to the locking wing nut, it’s possible to use the win-

dow bracket also for sliding windows. Position the hole of 
the bracket so to allow a correct installation of the exhaust 
hose (see figure 6).

AIR CONDITIONING WITH INSTALLATION

•  Fit the air exhaust hose (B2) in the relevant housing located 

on the rear side of the appliance (fig. 1).

•  Drill a hole 150 mm in an outside wall or through a window 

panel. Respect the distances, dimensions and heigh of the 
hole given in figure 8.

Summary of Contents for Pinguino Air-to-Air PAC EL112CST

Page 1: ...lease note This appliance is provided with an auto evapora tion feature for condensate removal during cooling and dehu midifing modes AIR CONDITIONING WITHOUT INSTALLATION CASEMENT WINDOW If you have a casement window proceed as follows Fittheairexhausthose B2 intherelevanthousinglocated on the rear side of the appliance fig 1 Screw the window outlet B7 and place outside the win dow to exhaust the...

Page 2: ...9 Dehumidifying symbol C10 Fan symbol C11 ECO REAL FEEL indicator C12 SILENT symbol C13 Auto indicator C14 Air flow indicators C15 Alarm symbol C16 ECO REAL FEEL symbol C17 Set temperature values programmed on off time TURNING THE APPLIANCE ON OFF Before plugging the appliance check thecaponbackoftheunitiscorrect ly inserted on drainage hose A10 Insert the plug in the socket Two dashes appear on t...

Page 3: ...liance To correctly set this mode Touch repeatedly the MODE key until the fan symbol appears Select the desired air flow by touching the increase C4 or decrease C3 key The air flows available are Minimumairflow whenmostsilentoperationis desired Medium air flow when the noise level needs to be low but with a good comfort level Maximum air flow for maximum performance SELECT THE TEMPERATURE SCALE Th...

Page 4: ... D1 When turned on the air conditioner starts operating in the same mode as when it was turned off Touchthe C1 C2 C4 C11 C13 C12 C9 C7 C5 C6 C3 C16 C14 C10 C15 C17 C8 ON STAND BYbutton D1 againtoswitchthe appliance off Please note Never switch the appliance off by removing the plug Always switch it off by touching the C1 C2 C4 C3 ON STAND BY but ton D1 and waiting few minutes before removing the p...

Page 5: ...dledPinguino appliance In case the user wants to perform a pairing with an other Pinguino device or in case of a pairing of brand new CST remote control the user needs to put the unit in Stand by mode andkeeptouchedfor10secsthe MODE selectionbutton D6 on the CST remote control The Led D10 starts blinking periodi cally indicating the pairing phase The user is then asked to press for 10 sec the MODE...

Page 6: ...s previously set Tocancelthetimerprogram touchthetimerbutton D5 twice The timer symbol C7 will go off Pleasenote Oncethetimerhasbeenactivated bytouchingthe timerkeyonlyonetime theremaininghourstothestartupwill be displayed USAGE TIPS The CST remote control has humidity temperature sensors onboard It is suggested not to completely cover it with hands or clothes it is as well suggested not to place ...

Page 7: ...hotter than 40 C After washing the filter allow it to dry completely before repositioning it START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the earth system is efficient Follow the installation instructions precisely END OF SEASON OPERATIONS To drain all water from the circuit remove the external cap by unscrewing it in the anticlockwise direction fig 12 and allow the ...

Page 8: ...bove there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the appliance fig 1 filter clogged clean or replace the filter as described above the technical specification of the appliance is not adequate for the room in which it is located During operation there is an...

Reviews: