background image

 

 

                                      LCP-1250RJ3SR-S

 

DELTA ELECTRONICS, INC.

 

  Oct. 17. 2007 Rev. 1.02

 

www.deltaww.com

 

Description 

The LCP-1250RJ3SR-S is a 3.3V copper 

small form-factor pluggable (SFP) transceiver. 
It offers full duplex 1000M/s Ethernet by 
transporting data over standard CAT 5 UTP 
cable

category 5 unshielded twisted pair, with 

R J-45 connection. It takes signals from both 
CAT 5 UTP cable and the SFP SerDes 
interface.  

The system host 

MAC

must enable 

SGMII auto-negotiation while 
LCP-1250RJ3SR-S is oper ated to setup the 
partner linking at one speed of 10/100/1000 
Mbps by 1000Base-T auto-negot iation. 

The Gigabit Ethernet SFP ports on host 

systems can work well plugging with both of 
Delta fiber SFP transceiver and Delta copper 
SFP transceiver, so there is no need of 
software to configure MAC on host system. 

At enhance, the software can configure the PHY 
device inner LCP-1250RJ3SR-S via SFP 
two-wire-interface. The SGMII interface without 
clock is selected by setting HWCFG_MODE[3:0] 
bits to ‘1100’ or    ‘1000’. 
 

Features 

 

Compliant with specifications for IEEE 
802.3z/Gigabit Ethernet 

 

Compliant with MSA specifications for Small 
Form Factor Pluggable 

SFP

Ports 

 

Hot-pluggable SFP footprint 

 

10/100/1000 BASE-T operation in the host 
system with SGMII interface (Default) 

 

1000 BASE-T operation in the host system with 
SerDes interface (To be configured) 

 

Compliant with industry standard RFT electrical 
connector and cage 

 

EEPROM with serial ID functionality 

 

Auto-Negotiation follows IEEE 802.3u Clause 
28 (1000BASE-T) and Cisco SGMII Spec. 

 

Compatible with the Cisco specification of 
SGMII interface.LCP-1250RJ3SR-S supports 
the SGMII interface without clock on MAC side. 

 

Gigabit PHY device is integrated internally 

 

Internal PHY IC is configurable by host system 
software via SFP 2-wire-interface. 

 

 

Applications 

 

Gigabit Ethernet over copper 

 

Switch to Switch interface 

 

Switched backplane applications 

 

File server interface 

 

Performance 

 

LCP-1250RJ3SR-S data link up to 100m on 
standard CAT 5 UTP 

 
 
 

Summary of Contents for LCP-1250RJ3SR-S

Page 1: ...wire interface The SGMII interface without clock is selected by setting HWCFG_MODE 3 0 bits to 1100 or 1000 Features Compliant with specifications for IEEE 802 3z Gigabit Ethernet Compliant with MSA specifications for Small Form Factor Pluggable SFP Ports Hot pluggable SFP footprint 10 100 1000 BASE T operation in the host system with SGMII interface Default 1000 BASE T operation in the host syste...

Page 2: ...Base T with SGMII interface by reconfiguration of the PHY within the SFP 3 This part supports the 10 100 1000 Base T with SGMII interface by default It can operate in 1000 Base T with SerDes interface by reconfiguration of the PHY within the SFP Serial Interface Configuration PHY Two Wire Address 0xAC Register Bits Field Mode Description 27 3 0 HWCFG_ MODE R W Changes to these bits are disruptive ...

Page 3: ...itter Disable Input High VDISH 2 0 VCC 0 3 V Transmitter Disable Input Low VDISL 0 0 8 V Receiver Data Output Differential Voltage VD RX 0 35 2 V 3 Differential Output Impedance ZRX 80 100 120 Ohm Data Output Rise Fall Time tr Rx tf Rx 180 ps 4 Notes 1 Internally AC coupled and terminated to 100 Ohm differential load 2 Pull up to VCC with a 4 7K 10K Ohm resistor on host Board 3 Internally AC coupl...

Page 4: ...ace 6 MOD DEF0 Module Definition 0 3 Note 3 grounded in module 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 Note 4 Function not available 9 VeeR Receiver Ground 1 Note 5 10 VeeR Receiver Ground 1 Note 5 11 VeeR Receiver Ground 1 Note 5 12 RD Inverse Received Data Out 3 Note 6 13 RD Received Data Out 3 Note 6 14 VeeR Receiver Ground 1 Note 5 15 VccR Receiver Power 2 Not...

Page 5: ...e two wire serial interface respectively 4 LOS Loss of Signal is not supported and tied to ground 5 VeeR and VeeT are internally connected within the copper SFP 6 RD and RD are the received differential outputs and they are AC coupled 100Ω differential lines that should be terminated with 100Ω differential at user s SERDES The AC coupling is done inside the copper SFP and thus not required on the ...

Page 6: ...LCP 1250RJ3SR S DELTA ELECTRONICS INC 6 Oct 17 2007 Rev 1 02 www deltaww com Recommend Circuit Schematic ...

Page 7: ...LCP 1250RJ3SR S DELTA ELECTRONICS INC 7 Oct 17 2007 Rev 1 02 www deltaww com Package Outline Drawing for Metal Housing ...

Page 8: ...0 64 00 89 DC 114 00 15 00 40 4C L 65 01 90 DC 115 00 16 00 41 43 C 66 00 91 DC 116 00 17 00 42 50 P 67 00 92 00 117 00 18 64 43 2D 68 SN Note 2 93 00 118 00 19 00 44 31 1 69 SN 94 00 119 00 20 44 D 45 32 2 70 SN 95 CS2 Note 4 120 00 21 45 E 46 35 5 71 SN 96 00 121 00 22 4C L 47 30 0 72 SN 97 00 122 00 23 54 T 48 52 R 73 SN 98 00 123 00 24 41 A 49 4A J 74 SN 99 00 124 00 Notes 1 Byte 63 CS1 Check ...

Page 9: ...SR GBIC Transceiver 1250Mb s data link up to 100 m on standard CAT 5 UTP References 1 Small Form factor Pluggable SFP Transceiver MultiSource Agreement MSA September 14 2000 2 IEEE Std 802 3 2002 Edition IEEE Standards Department 2002 3 AT24C01A 02 04 08 16 2 Wire Serial CMOS EEPROM Atmel Corporation www atmel com 4 Alaska Ultra 88E1111 Integrated 10 100 1000 Gigabit Ethernet Transceiver Marvell C...

Reviews: