background image

PPM DC1_100
Installation Manual

Delta Data Collector

The power behind competitiveness

www.deltaww.com

Summary of Contents for PPM DC1_100 Series

Page 1: ...PPM DC1_100 Installation Manual Delta Data Collector The power behind competitiveness www deltaww com ...

Page 2: ...tion 2 1 Installation on wall 2 2 Installation in box outdoor 2 3 Setting Connectors and Cables 2 4 Connection to the inverter 2 5 Download the APP 3 Supported inverter models 3 1 Normal mode 3 2 Retrofit mode 4 Specifications 5 When Something Seems Wrong Troubleshooting 5 1 Error Displays 5 2 Troubleshooting Appendix N1 Appendix N2 Appendix P1 Appendix P3 03 05 05 06 06 07 08 09 10 10 11 12 13 14...

Page 3: ...rmediate level injuries and in some cases may also result in serious injury or death Failing to handle the Product properly may result in the described danger leading to slight or intermediate level injuries or property damages in some instances Explanation of graphic symbols Electric Shock Precaution Notifications pertaining to precautions for potential electric shock under specific conditions Ge...

Page 4: ...he Product or apply any spray including combustible gases to the Product The Product may ignite or explode in the unlikely event such an occurrence takes place Do not install the Product in a place that is subject to significant effects of vibration and impact There is danger of injury from the Product falling in some rare cases Do not use organic solvents paint thinners benzene and the like stron...

Page 5: ...xpose to salt air Do not expose to corrosive substances explosive flammable GAS chemicals Do not install in direct sunlight Do not install in a place exceeding the operating temperature range 25 to 55 C Do not install above 2000m MSL or higher Do not expose to water vapor oil vapor smoke cotton dust metal powder sawdust If installed outdoor please put it in box which is suitable fo r outdoor use T...

Page 6: ... PH2 16 pin Connector DIN Rail Stopper This is a rail used to install the product on a wall These are wood screws for the Wall Surface Connect to the main unit 1 3 4 5 6 1 unit Main unit 1 piece Wi Fi Antenna Install antenna to Enhance Wireless Signals 2 1 piece 3 pieces 2 pieces 1 piece Quick Installation Guide 7 1 copy Installation Guide Stoppers to secure the installation of Data Collector on a...

Page 7: ...72 mm 90 mm 170 mm 117 mm 121 mm 55 mm unit mm 1 2 Dimension DC1 Din Rail 125 1 25 1 3 5 0 5 18 7 5 2 0 2 7 5 35 7 ...

Page 8: ...nnect the system to an ethernet cable USB terminal for USB Reserve of various data and maintenance can be performed Customers are requested to procure their own USB memory RS 485 a 16 pin terminal This is the terminal that is used to connect a 16 pin connector provided to link the supply of power and signals from the Inverter LED Explanation LED Explanation Green Green blinking Green Green Red Nam...

Page 9: ...et button System ready led flashing Action of DC1 3 5 sec 0 5sec ON 0 5sec OFF Rebuild wifi module 6 10 sec 1sec ON 1sec OFF Reset wifi password and rebuild wifi module Over 15sec 2sec ON 2sec OFF Reset DC1 setting without SN then reboot 9 ...

Page 10: ... Antenna should be placed in front of the concrete block in the transmission path Distance of the antenna from concrete block 15 cm Height difference between antenna and concrete block 10 cm antenna placed higher Substation Distance of the antenna from the substation 1 5 m High Voltage Transmission Tower Distance of the antenna from HV transmission tower 10 m RSSI SNR 105 dBm 2 dB D C B A C B A D ...

Page 11: ...xternal box is available for customer from Delta Contact retailer for more details 2 DC1 SUB_1G N1 1 Please prepare a protective case to protect Data Collector and Sub 1GHz module I If the external box is made of plastic material Wi Fi and Sub 1G antenna can be installed in the box If the external box is made of metal Wi Fi and Sub 1G antenna needs to be installed outside the Box G H 2 An external...

Page 12: ...d temperature 80ºC to 85ºC Process the cables before use 8mm Cable 40mm Φ 0 6 0 8 Φ 5 6 Assemble 16 pin connector Hold down the pin of 16 pin connector insert cable and connect connector to Data Collector Assemble communication connector Hold down pin of connector in inverter insert cable and connect connector to inverter 12 ...

Page 13: ...a 3 Next insert the cables into the adjacent inverter as follows 5 Data 6 Data Check that the cables have been inserted securely 4 Next insert the aforementioned cables into the adjacent inverter as follows 3 Data 4 Data 5 After completing the connection turn ON the terminal switch for only the inverter that is farthest from the Data Collector and set all the other inverter to 1 OFF Communications...

Page 14: ...er is not connected to cloud you still can monitor inverter operation by APP 3 Scan QR code for APP operation manual Where can search for MyDeltaSolar APP QR Code Please scan the QR code to MyDeltaSolar cloud IOS system Please search MyDeltaSolar in App store Android system Please search MyDeltaSolar in Google Play QR Code Please check the smart phone is connected to the Internet and the communica...

Page 15: ...Router Ethernet or Wi Fi Connection type DC1 Smartphone Wi Fi Hints and Tipps Connection type Solivia G3 Solivia G4 RPI HxA HXA_2XX M6A M8A M10A M15A M20A M30A M50A M70A M88H M125HV Wired RS485 not available Wi Fi y Mixed not available Hints and Tipps One of the connected inverters must have RS485 ID Inverter ID 1 3 Supported inverter models 3 1 Normal mode Inverter connect with DC1 via Wired RS 4...

Page 16: ... Ethernet Internal Wi Fi Module 802 11a b g n EN 61010 1 CE compliance EN 300 328 LP0002 Part 15C Telec T66 Immunity EMS I O Port EN 301 489 1 17 EN 55024 EN 55032 FCC Part 15B 2 pin terminal block for Power Port 4 pin terminal block for RS 485 2 pin terminal block for Can Bus 2 pin terminal block for Dry Contact 6 pin terminal block for digital inputs RJ 45 connector for Ethernet USB Port for dat...

Page 17: ...ooting 5 1 Error Displays When a problem occurs confirm the Error message from the ERROR EVENTS LOG page of History Details can be verified in the ERROR EVENTS LOG pages Refer to the Manual of the Inverter for details on the error codes 17 ...

Page 18: ... slow flashing The LED Light of Status turns red and fast flashing DC1 does not connect to internet Please go to the NETWORK page to set network For detailed setting process please refer to APP manual N1 or N2 is booting Please wait a minutes for the boot to complete Initialize N2 s RF module failed when connecting to an inverter Please confirm if there is a connection between N2 and Inverter if n...

Page 19: ...LED OFF Slow Flash OFF OFF OFF ON Update N1 card Description Update RF module No back end devices are connected Waiting for module initialization No Ext data transmission for more than 300 seconds No Int data transmission for more than 600 seconds Connecting Power ON Light Green LED OFF When the device is receiving power Description Powered off Reset Button Push 5 10s Push 15 20s Slow Flash Fast F...

Page 20: ...66 Immunity EMS I O Port EN 301 489 1 3 EN 55024 EN 55032 FCC Part 15B 6 pin terminal block 2 x RS 485 4 x GPIO Power SUB_1GHz 25 C 55 C 30 85 48 x 309 x 55 mm 100g 5 Dimensions 310 0 47 9 90 0 36 0 42 0 11 8 56 0 17 0 40 4 50 4 54 6 unit mm 7 Installation Diagram Install SUB_1G to Data collector 1 1 2 2 2 2 Screw torque required for assembling 0 6 N m 6 SUB_1G N1 Module Modulation techniques Band...

Page 21: ...nnecting to inverter Data Transfer OFF OFF Fast Flash Data transfer in progress Power ON Light Green LED OFF When the device is receiving power Description Powered off Reset Button Push 5 10s Push 15 20s Slow Flash Fast Flash Reset RF Description Reset RF Freq Default Band Others OFF OFF OFF OFF ON ON ON Invalid operation Red LED Yellow LED Green LED 1 1 6 5 4 3 2 2 Part Reset Button Fixed Point A...

Page 22: ... Emission EMI CONNECTION GENERAL INFORMATION LED Display Operation temperature Relative humidity Dimension WxHxD Weight PPM N2_SB1 12 Vdc 2 Watt RS 485 SUB_1G EN 61010 1 CE compliance EN 300 220 below 1G EN 50385 LP0002 Part 15C Telec T66 Immunity EMS I O Port EN 301 489 1 3 EN 55024 EN 55032 FCC Part 15B 2 pin terminal block for RS 485 Power SUB_1GHz 25 C 55 C 30 85 78 x 396 x 72 mm 150g 5 Dimens...

Page 23: ...on Limiting current RS 485 Input voltage range 100 240Vac 10 230VAC 50Hz 60Hz 5 2 W With Data Collector consumption 7 W 120A Electrical wire diameter Torque for screw terminal Weight without current transformer Dimensions W H D Ambient temperature in operation 15mm2 0 98 Nm 145g 72 mm x 90 mm x 55 mm 25 C to 60 C Ambient temperature during transport storage in accordance with IEC 61010 1 30 C to 7...

Page 24: ...cal wire diameter for AC terminal Torque for screw terminal for AC terminal Weight without current transformer Dimensions W H D Ambient temperature in operation 16 20 AWG 1 Nm 200 g 90 mm x 90 mm x 54 6 mm 20 C to 60 C Ambient temperature during transport storage in accordance with IEC 60950 25 C to 70 C Operating humidity 25 to 85 non condensing Storage humidity 25 to 85 non condensing ELECTRONIC...

Page 25: ...20210223 ...

Reviews: