background image

IRREVERSIBLE OPERATOR

FOR  SWING  GATES

AND DOORS

WARNING!! Before installing, thoroughly read this manual that is an   integral

part of the pack

The  CE  mark  conforms  to  European  directive

EEC 89/336 + 92/31 + 93/68 D.L. 04/12/1992 N. 476.

Our products if installed by qualified personnel capable to evaluate risks,

comply with norms UNI EN 12453, EN 12445

LINEAR-11

Summary of Contents for LINEAR-11

Page 1: ...thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 LINEAR 11 ...

Page 2: ...3 TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 5 6 TROUBLESHOOTING 7 SAFETY PRECAUTIONS 8 PACKING CONTENTS 1 OPERATOR 1 KIT FASTENING PLATES AND RELATIVE ACCESSORIES 1 UNLOCKING KEY 1 CONDENSER 230Vca ...

Page 3: ... temperature 20 C 55 C weight 8 Kg Protection rating IP 55 Opening time 90 15 sec Rod stroke 400 500 mm Force of thrust 1500 N Motor current input 1 5 A 1 A 2 5 4 3 1 1 5 6 7 8 VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS Optimal installation 1 Operator 2 External photocell 3 Flashing warning light 4 Antenna 5 Internal photocell 6 Electronic control unit 7 Key switch 8 Remote control TECHNIC...

Page 4: ...DIMENSIONS TYPICAL CONNECTION AND CABLE SECTION 2X1 5mm2 24 Vdc 4X1 5mm2 230 Vca 2X0 75mm2 4X0 75mm2 4X0 75mm2 2X0 75mm2 3X1 5mm2 230V Line 250 mm 520 620 mm 400 500 mm 88 mm RX Photocell TX Photocell ...

Page 5: ...ates using the data given in Table 1 bearing in mind that they are valid if the operator is at maximum extension minus one centimetre of the available stroke CD when the gate is closed to obtain maximum working efficiency 2 Data B in the table with reference to the single values A are to be considered as values recommended 3 To anchor the piston use the fastening brackets provided COORDINATES AND ...

Page 6: ...r use the key as shows the photo Turning the key of 90 the operator will be completely unblocked FIG 3 FIG 1 FIG 2 FIG 4 Installing the anchor plate on the piston to the gate 1 Fit the anchor plate onto the piston fig 4 2 Close the gate 3 Move the piston with the plate already fitted towards the gate 4 Move the fitting to limit stop then move it back by approximately 1 cm and mark the position of ...

Page 7: ...g or the beam is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote control the gate doesn t open but works with the key command The remote control has not been memorised or the battery is flat Carry out the remote control learning procedure on the radio receiver or replace the battery with a new one The gate starts but stops immediately The fo...

Page 8: ... or differential switch suitable for the product and conforming to current standards The manufacturer declines any and all responsibility for product integrity safety and operation in the event incompatible devices and or components are installed Solely original spare parts should be used for repairs and replacements The installer must provide all the information relating to the operation maintena...

Page 9: ...15 7550 216 7017 216 7018 Fax 218 5542 Mobil 30 940 1970 20 949 2688 1141 Budapest Fogarasi út 77 Tel 220 7940 220 7814 220 7959 220 8881 364 3428 Fax 220 7940 E mail delton delton hu Web www delton hu www kaputnyitunk hu Mobil 30 531 5454 30 939 9989 ...

Reviews: